人工植體兩種不同印模技術準確性之評估-+-The accuracy of two implant impression techniques

-+-

檔案

本條目沒有附加檔案。

類型

摘要

精確之主模型為牙科贗復體成功之先決條件,以往許多文獻都提及被動密合之贗復物,可以預防人工植體其上贗復物之併發症及預防植體周圍骨整合喪失。臨床上對於精確的最終印模,一直有新的材料與技術之發展,但是大部份的臨床醫師還是採用Zarb,Branemark等學者提出的最終印模法,即利用牙線或矯正金屬線作偽鷹架,再加入自聚性聚合樹脂,來防止方形轉移薄蓋冠於印模材內之轉位。本研究之目的乃以方形轉移薄蓋冠印模,比較使用預先製備之丙烯酸樹脂環及未使用丙烯酸樹脂環二種印模方式,並藉黏貼於金屬支架水平及垂直面上之應變測量儀,測量此二種不同印模方法所得之應變量,再以統計方法來觀察何者可以獲得較準確植體支柱間相關位置。結果顯示即使是依金屬支架製作出來之標準模型仍有應變存在。雖然使用丙烯酸樹脂環印模法可獲得較小應變量,但二組間並無統計上的差異,此外二組印模法於水平面之應變值與主模型間有統計學上的差異;但於垂直面之應變值,三者間均無統計學上的差異。就本研究之實驗條件下,臨床上直接採用方形轉移薄蓋冠印模,或許可以節省添加丙烯酸所造成耗時費事的過程。
Accurate master cast is the basic requirement for the fabrication of a precise dental prosthesis. Most literature related to implantology emphasized the importance of passively fitting fixed prosthesis to prevent the prosthodontic complications or even the loss of fixture integration. Recently, various impression material and techniques have been used to make the master cast more accureately. Most of the dentists use the procedure mentioned by Zarb and Branemark et al, which link the transfer copings together intraorally wuth the application of Duralay acrylic resin to the scaffolding of dental floss or orthodontic wire. The aim of this study was to evaluate the strain values, via two strain guages, which weregenerated by two different transfer impression techniques (nonsplint and splint with prefabricated Duralay acrylic resin ). The strain values were compared and analyzed stafistically to determine which impressuon procedure was more accurate than the other. The results showed that even though the master cast was fabricated from the master framework to assure a passive fit, strain can also be found in both the horizontal and vertical planes of the metal framework. While the mean strain values of splint group were smaller than nonsplint group. There was no statistically significant differences between these two impression techniques (P>0.05) The horizontal mean strain values of two groups were not significantly different from that of the standard to model. The vertical mean strain values of two groups were not significantly different from that of the standard model. Under the condition of this experiment, strain values were generated from both impression techniques. There appeared to be no clinical advantage to use the more time-consuming technidue of Splinting impression transfer copings with autopolymerized, actylic resin.
None

所屬典藏

測試學系
顯示完整詮釋資料 統計資料

引用此條目

黃怡芬 (1996). 人工植體兩種不同印模技術準確性之評估-+-The accuracy of two implant impression techniques. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/17099

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/17099