摘要

本研究目的在 探討以固相微量萃取(Solid PhaseMicro-extraction)法 分析飲用水中三鹵甲烷之可行性。本研究使用SPME吸附萃取分析物後,再將分析物注入氣相層析儀脫附與分析,結果發現,使用SPME法 分析飲用水中之三鹵甲烷的吸附時間為10分鐘,脫附時間為3分鐘,線性範圍在1μg/L--100μg/L之間,回收率為118%,精確度<7%,效果良好,可作為日後分析水中其他揮發性有機物之參考方法。 The purpose of the research was to evaluate the feasibility of pretreatmentwith solid phase microextraction(SPME) to analysis trigalomethanes(THMs) in drinking water. The SPME and G.C were used for analysis of trihalomethanes.
The results were show as follows:
1.Ty took ten minutes to adsorb trihalomethanes in drinking water by means of SPME method.
2.To desorb THMs from the solid phase took three minutes.
3.The linear rangi of quantitaiton was from 1 μg/L to 100 μg/Lof trihalomethanes.
4.The recovery rate of the established method was 118% and the precision under 7%.
The described method indicated effective for the analysis of THMs in drinking water. It would be applied to measure other volatile organic in drinking water in the future.