單光子雪崩二極體應用於高能量電子計數

Single-Photon Avalanche Diodes for Energetic Electron Counting

檔案

全文將於 2029年7月10日 起公開。

日期

2024

類型

語言

中文

摘要

本論文探討SPAD在高能量電子計數中的應用,旨在探討其偵測高能電子的可行性與量化。SPAD因其高靈敏度、快速響應、小尺寸和低成本等優勢,廣泛應用於量子通訊、醫學成像和光譜分析等領域。本研究引入SPAD技術,以期在電子偵測中實現更高的靈敏度和時間解析度。SPAD在光子偵測中表現優異,並已證明在正子、中子及其他高能粒子的偵測中具有潛力。然而,在電子偵測方面,現有技術在電子偵測方面尚缺乏對電子偵測效率的量化及理論模型。本研究通過模擬和實驗設計,首次定義、量化並驗證電子偵測效率。
研究通過TCAD和Casino軟體進行模擬,分析崩潰機率、載子收集效率和充電效應對電子偵測的影響。實驗方面,利用自製真空門和JSM-7000F SEM,測試不同結構元件在不同能量下的電子偵測效率。模擬結果顯示,介電層厚度是影響EDP的關鍵因素。實驗結果表明,SPAD在5到20 keV範圍內能夠有效偵測加速電子,且計數率隨能量增加而提高。EDP在61 nm ARC元件11 keV時,有最高偵測機率80 %,最低可測電流則為0.775 aA。此外,充電效應會影響電子偵測,需通過適當材料和導電防護設計減少影響。未來的研究可透過降低介電層厚度或背向入射設計來優化SPAD結構,並結合電子能量解析技術,提升偵測效率和系統性能,進一步作為SEM二次電子偵測器使用,擴展其應用範圍。
This thesis explores the application of SPAD in high-energy electron counting, aiming to investigate its feasibility and quantification for detecting high-energy electrons. Due to its advantages of high sensitivity, fast response, small size, and low cost, SPAD is widely used in fields such as quantum communication, medical imaging, and spectroscopy. This study introduces SPAD technology to achieve higher sensitivity and time resolution in electron detection. SPAD performs excellently in photon detection and has shown potential in detecting positrons, neutrons, and other high-energy particles. However, current technologies lack quantification and theoretical models for electron detection efficiency. This research defines, quantifies, and verifies electron detection efficiency (EDP) for the first time through simulations and experimental designs.
The study conducts simulations using TCAD and Casino software to analyze the impact of breakdown probability, carrier collection efficiency, and charging effects on electron detection. Experimentally, a custom-made vacuum chamber and JSM-7000F SEM are used to test the electron detection efficiency of different structured devices at various energies. Simulation results show that the dielectric layer thickness is a key factor affecting EDP. Experimental results indicate that SPAD can effectively detect accelerated electrons in the range of 5 to 20 keV, with the counting rate increasing with energy. The highest detection probability of 80% is achieved at 11 keV for a 61 nm ARC device, with the minimum detectable current being 0.775 aA. Additionally, charging effects influence electron detection and must be mitigated through appropriate material and conductive shielding design. Future research can optimize SPAD structures by reducing dielectric layer thickness or using back-illumination designs and combine energy-resolved electron detection techniques to enhance detection efficiency and system performance. This can further extend its application as a secondary electron detector for SEM.

所屬典藏

電子研究所
顯示完整詮釋資料 統計資料

引用此條目

黃子芸 (2024). 單光子雪崩二極體應用於高能量電子計數. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/2279

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/2279