音叉的工作原理與在探針顯微鏡上之應用
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
尹慶中 | |
dc.contributor.author |
柯文清 | |
dc.contributor.author |
||
dc.contributor.college |
工學院 | |
dc.contributor.committee |
||
dc.contributor.committee |
||
dc.contributor.department |
機械工程系所 | |
dc.contributor.studentid |
9014579 | |
dc.date.NCLavailable |
||
dc.date.USTavailable |
||
dc.date.issued |
2003 | |
dc.date.issuedROC |
92 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
91 | |
dc.description.abstract |
本文探討掃描式探針顯微鏡的探針與試片間非接觸作用力對於剪力回饋裝置共振頻率的影響,應用作用力與感測器振幅變化之特性,調控探針高度。剪力回饋感測器採用市售石英音叉振盪器,黏貼光纖探針完成,以尤拉梁振動模型分析軸向作用力與共振頻率改變的關係,並結合Argento和French計算公式,由實驗及共振分析獲得探針與試片間非接觸作用力與剪力回饋感測器共振頻率的關係曲線,得到一致性趨勢的結果。本研究撰寫Labview圖控式軟體,透過GPIB介面連結鎖相放大器及函數產生器,並以運動控制卡之數位訊號處理功能,成功研製成一部閉迴路剪力回饋掃描式探針顯微鏡。 | |
dc.description.abstract |
This thesis presents a study on the working principle of tuning-fork-based shear force feedback devices frequently used in a scanning probe microscope. Resonant frequency of the tuning fork varies since non-contact interaction force acts on the probe as its tip becomes very close to a sample. Variation of the vibrating amplitude at the inherent resonant frequency is often used as an index to adjust the tip-sample distance within optical near-field range. The shear force feedback device is made of a commercial quartz tuning fork glued together with an optic probe of 50 nm aperture along one of the fork arms. The fork arm is modeled as an Euler beam that vibrates laterally and subjects to an axial force. The resonant frequency shifts due to geometric stiffness change caused by the axial interaction force. Combined with the tip force-distance formula presented by Argento and French, this study establishes a useful relation between the resonant frequency shift and the tip force. It is also successfully used to measure the interaction force between an optic probe and a silicon wafer. A shear force feedback scanning probe microscope was further developed during this research by a LabVIEW program integrating a lock-in amplifier, function generator, DSP-based PI controller through a GPIB interface. | |
dc.description.abstractopendate |
||
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
中文摘要 i英文摘要 ii誌謝 iii目錄 iv圖表目錄 vi第一章 緒論 11.1研究背景 11.2文獻回顧 31.3 研究內容 5第二章 剪力回饋感測器的工作原理 62.1音叉的致動 62.1.1電極配置 62.1.2電場分析 62.1.3 石英音叉振動原理 122.2音叉在掃描式探針顯微鏡上的應用 132.2.1非接觸作用力在實驗中的應用 132.2.2 開迴路近場距離控制 162.2.3 閉迴路回饋近場距離控制 172.3軸力作用對自然頻率的影響 182.3.1 統御方程式 182.3.2 自然頻率分析 25第三章 實驗與分析 283.1 剪力回饋感測器的製作 283.1.1 光纖探針 283.1.2 探針的黏貼 293.1.3 音叉頻率響應量測 293.2 軸控運動機置 303.2.1 三軸壓電管電極配置 303.2.2 壓電管的變形分析 303.3 實驗及裝置 313.3.1 探針-試片距離響應曲線 313.3.2 開迴路近場距離控制 323.3.3 閉迴路近場回饋距離控制 33第四章 實驗結果與討論 344.1 剪力回饋感測器的頻率響應實驗結果與討論 344.2 探針-試片距離響應曲線 344.3 軸力對音叉自然頻率的影響 354.4 近場距離控制 37第五章 結論與展望 385.1結論 385.2未來展望 39參考文獻 41附錄一 46附錄二 47附表 48附圖 | |
dc.identifier.citation |
[1] E. Hecht (1987), Optics: 3rd edition, Adelphi Univ. Addison-Wesley, New York, p.471.[2] J. J. Hren, J. I. Goldstein, and D.C. Joy (1979), Introduction to analytical electron microscopy.[3] D.Sarid (1991), Sacnning Force Microscopy with Applications to Electric, Magnetic, and Atomic Forces, Oxford, New York.[4] A. G. T. Ruiter, J. A. Veerman, K. O. van der Werf, and N. F. van Hulst (1997), “Dynamic behavior of tuning fork shear-force feedback,” American Institute of Physics, 71(1), 28-30.[5] E. A. Synge (1928), “A Suggested method for extending mircoscopic resolution into the ultra-microscopic region,” Philosophical Magazine, 6, 356-362.[6] G. S. Kino (1987), Acoustic waves: devices, imaging, and analog signal processing, Prentice-Hall, New Jersey, p.165.[7] E. Betzig, J. K. Trautman, T. D. Harris, J. S. Weiner, R. L. Kostelak (1991), “Breaking the diffraction barrier: Optical microscopy on a nanometric scale,” Science, 251, 1468-1470.[8] D. W. Pohl, W. Denk, M. Lanz (1984), “Optical stethoscopy:Image recording with resolution ,” Appl. Phys. Lett., 44, 651-653.[9] E. Betzig, P. L. Finn, J. S. Weiner (1992), “Combined shear force and near-field scanning optical microscopy,” Appl. Phys. Lett., 60, 2484-2486.[10] R. Toledo-Crow, P. C. Yang, Y. Chen, M. Vaez-Iravani (1992), “Near-field differential scanning optical microscope with atomic force regulation,” Appl. Phys. Lett., 60, 2957-2959.[11] M. Tortonese, R. C. Barrett, and C. F. Quate (1993), “Atomic resolution with an atomic force microscope using piezoresistive detection,” Appl. Phys. Lett., 62, 834-836.[12] K. Karrai, R. D. Grober (1995), “Piezoelectric tip-sample distance control for near field optical microscopes,” Appl. Phys. Lett., 66, 1842-1844.[13] M. J. Gregor, P. G.Blome, J. Schofer, R. G. Ulbrich (1996), “Probe-surface interaction in near-field optical microscopy: The nonlinear bending force mechanism,” Appl. Phys. Lett., 68, 307-309.[14] P. Vigoureux (1950), Quartz Vibrators and their applications, London, London, p.3~4.[15] P. Vigoureux (1931), Quartz Resonators and Oscillators, London, London, p.3.[16] P. J. Chen (1988), “Electrically Driven Flexural Resonant Modes in Symmetrically Electroded X-cut and Z-cut Quartz Discs”, IEEE Transactions on Ultrasonics, Ferroelectrics, and frequency control, 35(1), 66-72.[17] S. Lee (2002), “Fabrication of an array of surface mount device 32.768kHz quartz tuning fork-type crystals: photolithography and selective etching of an array of quartz tuning fork resonators with subsequent photoresist spray coating,” Vacuum, 65, 161-168.[18] G. Thornell, H. Rapp, K. Hjort (2000), “X-cut miniature tuning forks realized by ion track lithography,” IEEE transactions on ultrasonics, ferroelectrics and frequency control, 47,8-15.[19] D. K. Cheng (1989), Field and Wave Electromagnetics, Addison Wesley, California, p.174~182.[20] Taylor et al. (1985), Piezoelectricity, Gordon and Breach Science, Switzerland, p.47~60.[21] D. Salt (1987), Hy-Q handbook of quartz crystal devices, Van Nostrand Reinhold, Berkshire, p.8~12.[22] ANSI/IEEE (1988), An American national standard, IEEE standard on piezoelectric, New York, p.240.[23] A. Crottini, J. L. Staehli, B. Deveaud, X. L. Wang, M. Oqura (2002), “Ultra stable tuning fork sensor for low-temperature near-field spectroscopy,” Ultramicroscopy, 90, 97-101.[24] J. Rychen, T. Ihn, P. Studerus, A. Herrmann, K. Ensslin, H. J. Hug, P. J. A. van Schendel and H. J. Guntherodt (2000), “Operation characteristics of piezoelectric quartz tuning forks in high magnetic at liquid helium temperatures,” American Institute of Physics, 71, 1695-1697.[25] J. Rychen, T. Inn, P. Studerus, A. Herrmann, and K. Ensslin (1999), “A low-temperature dynamic mode scanning force microscope operating in high magnetic fields,” American Institute of Physics, 70(6), 2765-2768.[26] C. Argento and R. H. French (1996), “Parameter tip model and force –distance relation for Hamaker constant determination from atomic force microscopy,” American Institute of Physics, 80(11), 6081-6090.[27] J. H. Scofield (1994), “A frequency-domain description of a lock-in amplifier,” American Journal of Physics, 62, 129-133.[28] H. F. Tiersten (1969), Linear Piezoelectric Plate Vibrations, Plenum, New York, p.41~46.[29] C. L. Dym, I. H. Shames (1973), Solid Mechanics a Variational Approach, McGraw Hill, New York, p.370~377.[30] D. J. Gorman (1975), Free Vibration Analysis of Beam and Shafts, John Wiley & Sons, New York, p.359~363.[31] S. P. Timoshenko, J. M. Gere (1963), Theory of Elastic Stability, McGraw Hill, Auckland, p.152~155.[32] L. Meirovitch (1997), Principles and Techniques of Vibrations, Prentice-Hall, New Jersey, p.400~406.[33] S. Yang and W. Huang (1997), “Transient responses of a piezoelectric tube scanner,” American Institute of Physic, 68(12), 4483-4487.[34] W. H. J.Rensen, N. F.van Hulst, A. G. T. Ruiter and P. E. West (1999), “Atomic steps with tuning-fork-based noncontact atomic force microscopy,” Appl. Phys. Lett., 75, 1640-1642.[35] Y. Seo, J. H. Park, J. B. Moon, W. Jhe (2000), “Fast-scanning shear-force microscopy using a high-frequency dithering probe,” American Institute of Physics, 77(26), 4274-4276.[36] 翁崇銘(1996),近場光學顯微鏡之架設與特性研究,國立交通大學光電工程研究所碩士論文,台灣,新竹市。[37] A. Kikukawa, S. Hosaka (1995), “Phase-locked noncontact scanning force microscope,” American Institute of Physics, 66(1), 101-105.[38] W. A. Atia, C. C. Davis (1997), “A phase-locked shear-force microscope for distance regulation in near-field optical microscopy,” Appl. Phys. Lett., 70, 405-407.[39] M. Doi,Y. Iwasaki, T. Shionoya, K. Okamoto (1997), “High-resolution displacement measurement using mode interference in the optical waveguide,” IEEE Photonics Technology Letters, 9, 651-653.[40] S. Rozhok, V. Chandrasekhar (2002), “Application of commercially available cantilevers in tuning fork scanning probe microscopy (SPM) studies,” Solid State Communications, 121, 683-686.[41] D. V. Serebryakov, A. P. Loginov, V. S. Letokhov (2002), “Tuning-fork-based fast highly sensitive surface-contact sensor for atomic force microscopy/near-field scanning optical microscopy,” Review of Scientific Instruments, 73, 1795-1802.[42] R. D. Grober, J. Acimovic, J. Schuck, D. Hessman, P. J. Kindlemann (2000), “Fundamental limits to force detection using quartz tuning forks,” American Institute of Physics, 71(7), 2776-2780.[43] R. Brunner, O. Marti, O. Hollricher (1999), “Influence of environmental conditions on shear-force distance control in near-field optical microscopy,” American Institute of Physics, 86, 7100-7106. | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/26537 | |
dc.language.iso |
中文 | |
dc.relation.alma |
990009507600206772 | |
dc.relation.page |
82 | |
dc.subject.keyword |
石英音叉 | |
dc.subject.keyword |
掃描式探針顯微鏡 | |
dc.subject.keyword |
探針試片距離 | |
dc.subject.keyword |
共振頻率 | |
dc.subject.keyword |
quartz tuning fork | |
dc.subject.keyword |
scanning probe microscope | |
dc.subject.keyword |
tip sample distance | |
dc.subject.keyword |
resonant frequency | |
dc.title |
音叉的工作原理與在探針顯微鏡上之應用 | zh-TW |
dc.title |
en | |
dc.type |
Thesis | zh-TW |
檔案
本條目沒有附加檔案。
所屬典藏: 機械工程學系