懸索強迫振動試驗與分析
Forced Vibration Tests and Analysis of a Suspension Cable
摘要
本文旨在發展懸索結構之強迫振動分析理論,以探討其在簡諧擾動下的動態行為與減振控制效能,並完成一系列強迫振動試驗,透過試驗與模擬分析結果之比較驗證其合理性。強迫振動試驗係利用四核心激振器作為擾動源,於不同位置(模態振形腹點或懸索端點)加載以評估減振裝置(包括Large SB, small SB及其等重質塊)之振動控制效益,並探討減振功效究竟係源於stockbridge之阻尼特性或慣性質量。當擾動源與減振裝置佈設於模態振形腹點處時,激振懸索第一、二模態(f = 1.89 Hz及3.64 Hz)的結果顯示,減振裝置均會抑制振動反應,且較重的裝置抑制效果為佳;激振第三模態(f = 5.88 Hz)的結果則顯示,受到質量非對稱佈設的影響,僅與減振裝置同側的振動反應受到抑制,另一側的反應反而放大。當擾動源與減振裝置佈設於端點處對懸索振動反應的抑制效果不如佈設於振形腹點處,但受質量非對稱佈設的影響較小,不同振頻的振動反應都被抑制。整體而言,不論擾動源與減振裝置佈設點為何,擾動源擾動愈大,減振裝置的抑制表現愈好,且以較重的裝置表現較優。另一方面,SB對懸索的減振性能與等重質塊並無明顯差異,說明SB並非由阻尼作用抑制懸索振動,而是基於慣性質量達到減振控制目的。試驗與模擬分析結果之比較顯示,多數案例兩者有極佳之相關性,驗證本文所發展之懸索強迫振動理論模型的合理性,可提供未來實際工程應用之參考。
This study aims to develop a forced vibration analysis theory for cable structures, investigating their dynamic behavior and vibration control effectiveness under harmonic disturbances. A series of forced vibration tests were conducted to validate the developed theory by comparing experimental results with simulation analyses. The forced vibration tests utilized the four-core shaker as the disturbance source. This shaker was applied at different locations (modal antinode or cable end) to evaluate the vibration control effectiveness of various damping devices, including large SB, small SB, and their equivalent mass blocks. The study also aimed to determine whether the damping efficacy of the Stockbridge damper (SB) is derived from its damping properties or inertial mass. When the disturbance source and damping devices were positioned at the modal antinode, the results showed that the damping devices suppressed the vibrational response for the first and second modes (f = 1.89 Hz and 3.64 Hz), with the heavier devices providing better suppression. For the third mode (f = 5.88 Hz), the results indicated that due to the asymmetric mass distribution, only the vibrational response on the same side as the damping device was suppressed, while the response on the opposite side was amplified. When the disturbance source and damping devices were placed at the cable end, the suppression effect was less effective compared to placement at the modal antinode. However, the influence of asymmetric mass distribution was less pronounced, and the vibrational responses at different frequencies were all suppressed. Overall, regardless of the placement of the disturbance source and damping devices, the greater the disturbance from the shaker, the better the suppression performance of the damping devices, with heavier devices performing more effectively. Furthermore, the vibration suppression performance of the SB did not show significant differences compared to the equivalent mass blocks, indicating that the SB achieves vibration control through its inertial mass rather than its damping properties. The comparison between the experimental results and simulation analysis showed a high correlation in most cases, validating the rationality of the forced vibration theory model for cable structures developed in this paper, which can provide valuable insights for future practical engineering applications.