儲存槽之結構健康監測技術
Structural Health Monitoring Technology for Storage Tanks
摘要
本研究以中油一座一萬公秉儲油槽為標的,考慮基礎土壤不均勻沉陷之破壞模式,旨在探討由地震反應監測資料進行非剛性儲存槽之系統識別及結構損傷探測的可行性。本文在Ansys架構下建模分析,並與二維非剛性儲存槽流-固耦合分析理論之解析解比對,確認由Ansys數值模型所得動力參數之合理性。特徵分析結果顯示,健康模型與破壞模型的動力特性變化以衝擊模態較為顯著,因此,採用遞迴式系統識別法R4SID識別儲存槽水平向衝擊模態,根據無阻尼模態向量重建系統等效柔度矩陣,作為損傷探測分析之依據,探討不同監測數量與位置等條件下對識別精度及損傷探測之影響。分析結果顯示,方案A(6個監測點)系統識別及損傷探測結果未如方案B(12個監測點)及方案C(24個監測點)之觀測配置理想,於三組案例域雖然都能找到下陷區,但也都有一處誤判;方案B與方案C之觀測配置則大都能正確找出下陷區且無誤判,基於經濟性考量,以方案B之配置為最佳。另根據柔度矩陣相似度指標(FSI值)結果顯示,相較周圍底板沉陷,中央底板沉陷之受損模式對於結構系統參數變化更為敏感。綜而言之,本文提出之應力指標可以反映基礎土壤下陷之情況,結構健康監測技術用於儲存槽具有發展潛力。
This study targets a 10,000-cubic-meter oil storage tank of CPC Corporation, Taiwan, considering the damage mode due to uneven foundation settlement. The aim is to investigate the feasibility of system identification and structural damage detection for non-rigid storage tanks using seismic response monitoring data. The modeling and analysis were conducted within the Ansys framework, and the results were compared with the analytical solutions of the two-dimensional fluid-structure interaction theory for non-rigid storage tanks to validate the dynamical parameters obtained from the Ansys numerical model. The characteristic analysis results indicated that changes in the dynamic characteristics between the intact and damaged models were most significant in the impulsive modes. Therefore, the R4SID system identification method was employed to identify the horizontal impulsive modes of the storage tank. The equivalent flexibility matrix, reconstructed from the undamped normal modes, serves as the basis for damage detection analysis. This study examined the influence of different monitoring quantities and positions on the accuracy of system identification and damage detection. The analysis results showed that the system identification and damage detection outcomes for Scheme A (6 monitoring points) were less ideal compared to the observation configurations of Scheme B (12 monitoring points) and Scheme C (24 monitoring points). Although Scheme A could locate the settlement area in all three cases, it also had one false positive in each case. In contrast, Schemes B and C mostly correctly identify the settlement regions without any false positives. From an economic perspective, Scheme B's configuration was determined to be the optimal choice. Furthermore, the Flexibility Similarity Index (FSI) results demonstrated that the damage mode of central bottom slab settlement was more sensitive to structural system parameter changes compared to peripheral bottom slab settlement. In conclusion, the proposed stress index effectively reflects the condition of foundation soil settlement. Structural health monitoring technology shows great potential for application in storage tanks.