輕負載自動倉儲系統防火設計探討 -以某電子業為例

A Study on Fire Protection Design of Mini-load Automated Storage System - Taking a certain electronics industry as an example

檔案

日期

2024

類型

語言

中文

摘要

製造業為提升生產效率與產值,導入不同型式之自動倉儲,電子業為實現全線自動化,導入輕負載自動倉儲應用,為增加單位面積儲物量,堆疊高度增加及料盒間距縮減,在儲物密度高且叉車系統阻擋狀況下,初期火災偵測及滅火面臨挑戰。近年幾起自動倉儲火災,因滅火不易致災損嚴重,然國內尚無輕負載自動倉儲明確防火設計規範可供參。
本研究以某電子業場域之輕負載自動倉儲,主體以FDS模擬網格25cm設定,撒水頭位置依FM財產防損資料表建議配置,並增設偵煙感知器比較其偵測效度。本研究之火源設計為底層料盒起火,火源1/3面積位於底層料盒下方,熱釋放率為100kW,以FDS軟體模擬密閉濕式、一般開放式及細水霧三種自動撒水系統,然細水霧又分別設定兩種不同粒徑,搭配偵煙感知器啟動一般開放式及細水霧系統應用,共四種模擬情境探討其滅火效益。結果發現,以粒徑400μm之細水霧撒水,整體滅火效益最佳,滅火時間最短僅12.8秒,且用水量最低僅13.7公升。觀察發現採用偵煙感知器於初期火災發生3.93秒時,偵煙感知器已作動,其偵測效度優於溫度感知,及早啟動撒水,可提升滅火效益。彙整模擬結果與觀察後,提出結論與建議,供業界輕負載自動倉儲防火設計應用及政府修法參考。
To enhance production efficiency and output, the manufacturing industry has introduced various types of automated storage systems. The electronics industry, aiming for full-line automation, has implemented Mini-load automated storage applications. To increase storage capacity per unit area, stacking height has been increased, and the spacing between bins has been reduced. This high storage density, coupled with the obstruction of forklift systems, poses challenges for early fire detection and extinguishing. Several automated storage fires in recent years have resulted in significant damage due to the difficulty of extinguishing them. However, there are no clear fire protection design standards for Mini-load automated storage systems in the country.
This study focuses on the Mini-load automated storage system of an electronics facility. The main structure is designed using FDS (Fire Dynamics Simulator) with a grid size of 25 cm. Sprinkler head positions are arranged according to FM Global property loss prevention data sheets, with additional smoke detectors installed. Both general open and water mist systems are activated 5 seconds after the smoke detectors are triggered. The fire source is designed to originate from the bottom layer of the storage bins, with one-third of the fire area located below the bottom bin, and a heat release rate of 100 kW/m². Using FDS, this study simulates three types of sprinkler systems: wet pipe sprinkler system, deluge sprinkler system, and water mist systems. The water mist is set two different particle sizes, resulting in four simulation scenarios to explore their fire extinguishing effectiveness. The results show that the water mist sprinkler with a droplet size of 400 μm has the best overall fire extinguishing efficiency, with the shortest extinguishing time of only 12.8 seconds and the lowest water usage of only 13.7 liters. Observations revealed that the smoke detector activated at 3.93 seconds after the initial fire, indicating its superior detection accuracy compared to temperature sensors, thereby enabling early sprinkler activation and enhancing fire extinguishing efficiency. Based on the simulation results and observations, relevant conclusions and recommendations are presented for industry design applications and government legislative reference.
顯示完整詮釋資料 統計資料

引用此條目

陳軒怡 (2024). 輕負載自動倉儲系統防火設計探討 -以某電子業為例. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/3105

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/3105