生醫應用上之蠕動式微幫浦性能探討
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
陳俊勳 | |
dc.contributor.advisor |
Chiun-Hsun Chen | |
dc.contributor.author |
關恕 | |
dc.contributor.author |
Kuan Shu | |
dc.contributor.college |
工學院 | |
dc.contributor.committee |
||
dc.contributor.committee |
||
dc.contributor.department |
機械工程系所 | |
dc.contributor.studentid |
9314561 | |
dc.date.NCLavailable |
2009/07/24 | |
dc.date.USTavailable |
2009/07/24 | |
dc.date.issued |
2006 | |
dc.date.issuedROC |
95 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
94 | |
dc.description.abstract |
本論文描述利用微機電系統技術的壓電無閥門蠕動式微型幫浦的設計、製程與應用。微幫浦驅動原理在於PZT受到驅動訊號使得致動薄膜做往覆週期的運動。如此的裝置就如同活塞提供動力驅動微升等級的流體,如此可利用到許多生醫應用上的實驗室晶片。因此,本論文便是針對微幫浦的性能分析而探討,主要可分成兩部分。 首先,我們關注的是系統與週遭環境對輸出共振頻率的影響。為提高蠕動式微型幫浦的輸出能力,從理論上分析了負載流體對致動薄膜動態特性的影響規律。除了流體的密度以及黏滯性會對附加質量及附加阻尼造成影響外,流室深度以及驅動相位亦會影響致動薄膜動態特性,造成頻率位移現象。其次,流體的傳輸能力與電路的設計是具有緊密的連結。因此藉由適當電路設計的改良能有效提升傳輸流量 1.9~2.8 倍。 | |
dc.description.abstract |
A valveless peristaltic micropump based on piezoelectric actuation was designed and fabricated. The pump diaphragms are excited by applying pulse signal voltages to three lead zirconate titanate (PZT) disks on glass diaphragm. Such diaphragm structure acts as a “piston” to provide power for the handling of microliter-scaled fluid volumes desired in many lab-on-a-chip chemical and biomedical applications. A high-performance micropump was investigated for this purpose. The paper contains mainly two parts as follows. First, we are concerned with the interactions between a system and its environment for the influence on output resonance frequency. Analytical results for frequency shift was presented to show that not only does the added mass and added damping depend on both the fluid density and viscosity, the chamber height and actuated signal are as well. Second, the driving circuit can be closely linked with the fluid transport related to the pump performance. Therefore, the improvement design for driving circuit can enhance pump flow rate performance up to 1.9~2.8 times. | |
dc.description.abstractopendate |
||
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
Chapter1 Inefinitesimal Machinery: An Intrigued Word...131.1 Introduction……………………………………………………..131.2 Literature review………………………… .............16Chapter2 The Damping Effects on the Micro-diaphragm......262.1 Piezoelectric materials…………...………………….. 262.2 Performance of the frequency-dependent flow rate….282.3 Analysis of the simplified micropump for the flow rate..352.4 The added mass and added damping……………………….402.5 Analysis of the frequency shift with the interactions exerted on the micro-diaphragm……………..……………...432.6 The system dynamic for a peristaltic micropump…… 48Chapter 3 Fabrication and Test........................…683.1 Design and fabrication of a peristaltic micropump…683.2 Experimental setup……………………………………... 723.3 Experiments and results………………………………… 73Chapter 4 Results and Discussion.......................904.1 Discussion and conclusion……………………………... 904.2 Outlook……………………………………………………. 91References.............................................93 | |
dc.identifier.citation |
[1] Richard P. Feynman, There is plenty of room at the bottom,Journal of Microelectromechanical System vol. 1. No.1. March 1992[2] A. Manz, N. Graber, H.M. Widmer, Miniaturized total chemical analysis systems: a novel concept for chemical sensing, Sens. Actuators B 1 (1990) 244–248.[3] http://www.coventor.com/microfluidics/labonchip.html[4] Minqiang Bu, Tracy Melvin, Graham Ensell, James S Wilkinson and Alan G R Evans, Design and theoretical evaluation of a novel microfluidic device to be used for PCR, J. Micromech. Microeng. 13 (2003) S125–S130[5] Jing Cheng and Larry J. Kricka, Biochip Technology, Harwood Academic Publishers, 2001[6] Johnson P. and Lloyd-Jones J.G., Drug delivery system: fundamentals and techniques, Weinheim, New York, 1987[7] J.G. Smits, Piezoelectric micropump with three valves working peristaltically, Sensors and Actuators A21–A23 (1990) 203–206.[8] Dae-Sik Lee, Hyun C. Yoon, Jong Soo Ko, Fabrication and characterization of a bidirectional valveless peristaltic micropump and its application to a flow-type immunoanalysis, Sensors and Actuators B 103 (2004) 409–415[9] Woias P 2001 Micropumps—summarizing the first two decades Proc. SPIE 4560 35–52[10] Laser D J and Santiago J G 2004 A review of micropumps J. Micromech. Microeng. 14 R35–64[11] Peter Woias, Micropumps—past, progress and future prospects,Sensors and Actuators B 105 (2005) 28–38[12] Nguyen,Nam-Trung and Steven T., Fundamentals and applications of microfluidics, Wereley,2002.[13] Ahn, Chong H.; Allen, Mark G., Fluid micropumps based on rotary magnetic actuators, Source: Proceedings of the IEEE Micro Electro Mechanical Systems (MEMS), 1995, p408-412[14] R. Linnemann, P. Woias, C.-D. Senfft, et al., A self-priming and bubble-tolerant piezoelectric silicon micropump for liquid and gases, in: Proceedings of the 11th IEEE MEMS 1998 TechnicalDigest, Heidelberg, Germany, January 25–29, 1998, pp. 532–537.[15] Olsson, A.; Stemme, G.; Stemme, E., Simulation studies of diffuser and nozzle elements for valve-less micropumps , Solid State Sensors and Actuators,1997. TRANSDUCERS '97 Chicago, 1997 International Conference on, Volume: 2, 16-19 June[16] Ron L. Bardell and et al, “Designing high performance micro-pumps based on no-moving-parts valves,” in Microelectromechanical Systems (MEMS). ASME IMECE, 1997, vol. DSC-Vol.62/HTD-Vol.354, pp. 47–53.[17] H. Van Lintel, F. van de Pol, S. Bouwstra, A Piezoelectric micropump based on micromachining of silicon, Sensors and Actuators A15 (1988) pp.153-168[18] Olsson A, Stemme G and Stemme E 1999 A numerical design study of the valveless diffuser pump using a lumped-mass model J. Micromech. Microeng. 9 34–44[19] Olsson A, Enoksson P, Stemme G and Stemme E 1997 Micromachined flat-walled valve diffuser pumps IEEE/ASME J. Microelectromech. Syst. 6 161–6[20] Ullmann A, The piezoelectric valve-less pump-performance enhancement analysis, Sensors and Actuators A 69 97–105[21] Pan L S, Ng T Y, Liu G R, Lam K Y and Jiang T Y 2001 Analytical solutions for the dynamic analysis of a valveless micropump—a fluid–membrane coupling study Sensors and Actuators A 93 173–81[22] Pan L S, Ng T Y, Wu X. H and Lee H P, Analysis of valveless micropumps with inertial effects, J. Micromech. Microeng. 13 (2003) 390–399[23] Tikeswar Naik, Ellen K. Longmire, Susan C. Mantell, Dynamic response of a cantilever in liquid near a solid, Sens. Actuators A 102 (2003) 240–254.[24] Kan Junwu, Yang Zhigang, Peng Taijiang, Cheng Guangming, Wu Boda, Design and test of a high-performance piezoelectric micropump for drug delivery, Sensors and Actuators A 121 (2005) 156–161[25] B Husband, M Bu, A G R Evans and T Melvin, Investigation for the operation of an integrated peristaltic micropump, J. Micromech. Microeng. 14 (2004) S64–S69[26] Nam-Trung Nguyen, Xiaoyang Huang, Miniature valveless pumps based on printed circuit board technique, Sensors and Actuators A 88 (2001) 104-111[27] T. Ikeda ,Fundamentals of Piezoelectricity, Oxford ;Oxford University Press,1990.New York[28] Xing Yang et al. , A micro diaphragm air pump for air supply of micro fuel cell, proceedings of transducers’05, 13th international conference on solid-state sensors, Actuators and Microsystems, Seoul,Korea,2005[29] Fox and McDonald, Introduction to fluid mechanics, New York: Wiley, 1990.[30] Timoshenko S. P. and Weaver, W., Vibration Problems in Engineering, 4th ed., John Wiley, New York, 1974.[31] http://www.piezo.com/prodsheet2sq5H.html#priceinfo | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/31433 | |
dc.language.iso |
英文 | |
dc.relation.alma |
990010158290206772 | |
dc.relation.page |
96 | |
dc.subject.keyword |
蠕動式微幫浦 | |
dc.subject.keyword |
阻尼效應 | |
dc.subject.keyword |
微薄膜 | |
dc.subject.keyword |
頻率位移 | |
dc.subject.keyword |
Peristaltic micropump | |
dc.subject.keyword |
The damping effects | |
dc.subject.keyword |
Micro-diaphragm | |
dc.subject.keyword |
Frequency shift | |
dc.title |
生醫應用上之蠕動式微幫浦性能探討 | zh-TW |
dc.title |
Analysis of the Performance on Peristaltic Micropumps for Biomedical Applications | en |
dc.type |
Thesis | zh-TW |
檔案
- 456101.pdf (3.50 MB, Adobe PDF)
所屬典藏: 機械工程學系