摘要

在此論文中,我們將表面增強型拉曼散射(Surface enhanced Raman Scattering, SERS)之技術應用於單分子的偵測,以及尿液多成分分子之量測與定量分析。本研究量測極低濃度(10-11M)的R6G分子,已達單顆分子偵測的靈敏度:藉由514.5的激發波長、奈米膠體銀粒子,以及使用氯化鈉,使銀粒子產生聚集效應,提供足夠的拉曼訊號的增強,並藉由氯離子的存在,使R6G較易吸附於銀的表面。我們成功地觀察到R6G的SER光譜在1250-1700cm-1有強度隨時間不規則變動的現象,此乃SERS偵測單分子的證據。
在SERS偵測生物分子的應用上,本研究利用拉曼光譜之高度分子解析力,應用於尿液成份之分析。我們利用光學方法,不需多種特異性反應試劑的特性,量測尿液拉曼光譜而獲得多種尿液成分的資訊。而在定量實驗中,我們發現SERS訊號強度不一定隨濃度增加呈線性的增強; SERS訊號強度尚和待測物與膠體銀溶液混合的時間有關;他種分子也會影響標的分子的SERS訊號強度。本研究量測濃度範圍0.5~0.75 mg/dl之純肌酸酐, SERS訊號強度和濃度有良好線性關係,相關係數之平方可達0.9;以及在尿液控制劑中,SERS訊號強度和肌酸酐及尿酸之濃度也有線性關係,相關係數之平方可達0.9。而真人尿液的量測中,我們使用一尿液樣本稀釋成不同倍率作量測,SERS訊號強度和肌酸酐及尿酸之濃度也有線性關係,相關係數之平方皆可達0.9。由本研究可得知,表面增強型拉曼光譜對於生物分子多成分分析有很好潛力,但利用膠體銀溶液在定量分析上,尚有許多困難,只有在較單純的環境中,可以在一濃度範圍內達到定量分析。
In this thesis, we applied surface enhanced Raman scattering (SERS) technique to single molecule detection and multiple components detection and quantitative analysis of urine. By using Argon laser at 514nm, silver nano-particles, and sodium chloride which provides enough aggregation for SERS enhancement, we measured 10-11M R6G to achieve the sensitivity at the single molecule level. We successfully observed the fluctuation of SERS intensity of R6G and this is the evidence of single molecule detection by SERS technique.
In biomolecular detection, we applied SERS technique to analyze multiple components of urine. Comparison with biochemical method, the information of multiple components in urine can be obtained by single spectral measurement. In the quantitative experiment, we found that SERS intensity is not always linearly proportional to the concentration and it was also influenced by time after mixing of colloid and sample, and the other components in the mixture. We have obtained the square of correlation coefficient between SERS intensity and creatinine concentration which ranged form 0.5-0.75 mg/dl is 0.9. In the detection of urine control and the dilution of real urine, both creatinine and uric acid concentration have good linear relationship with SERS intensity. This research demonstrated the feasibility of SERS technique for multiple component measurement of urine and indicated the difficulties of quantitative analysis by SERS using Ag colloid.
顯示完整詮釋資料 統計資料

引用此條目

王翠蓮 (2005). 表面增強拉曼光譜技術應用於單分子偵測. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/32672

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/32672