台灣地區94年總廢塑膠容器的回收量約14.8萬噸,處理如此巨大的量是十分重要的問題。目前台灣對廢塑膠容器是採用回收再利用的方式,而回收再利用的處理過程,包含熱熔處理的步驟,會有惡臭及多種空氣污染物的產生;其中臭味讓人感覺不適,且熱熔過程中所排放之廢氣含有多種化學物質,其中包含對人體有致癌性和致突變性的多環芳香族碳氫化合物(PAHs)。
本研究針對台灣有登記的34間回收公司之工廠中,隨機選取19間廢塑膠回收處理工廠周界進行臭氣採樣,利用環檢所公告之「臭味與異位官能測定法-三點比較式嗅袋法」來測定廢塑膠回收工廠周界的臭味濃度值。以鐵氟龍濾紙連接採樣幫浦收集工廠周界空氣中之總懸浮微粒,進而以高效能液相層析儀(HPLC)測定微粒中所含之多環芳香族碳氫化合物濃度,以了解台灣地區廢塑膠回收工廠之分布情形、周界臭味程度、空氣中總懸浮微粒濃度和微粒中所含之多環芳香族碳氫化合物濃度。
本研究測得之廢塑膠熱熔處理廠的周界下風處臭味濃度平均值±標準差為167.5±115.07,廢塑膠破碎收集廠周界下風處臭味濃度平均值±標準差為76.57±37.28,經過統計檢定後,發現兩者的臭味濃度有統計上顯著差異(P=0.013),顯示廢塑膠熱熔處理廠的熱熔排煙會明顯增加工廠周界的臭味濃度。熱熔處理廠周界空氣中之總懸浮微粒濃度介於45.62~347.23μg/m3之間,破碎收集廠的總懸浮微粒濃度介於64.44~1356.61μg/m3之間,熱熔處理廠和破碎收集廠的總懸浮微粒濃度沒有統計上顯著差異(P=0.083),但其中熱熔處理廠的工廠周界和其環境道路之總懸浮微粒濃度有統計上顯著差異(P=0.05),表示熱熔處理廠的運作確實會增加周界空氣中的總懸浮微粒濃度。
熱熔處理廠的總PAHs濃度介於8.92~25.04 ng/m3之間,破碎收集廠的總PAHs濃度介於14.48~24.06ng/m3之間,熱熔處理廠和破碎收集廠的空氣中總PAHs濃度無統計上顯著差異(P=0.45)。PAHs種類上,在熱熔處理廠之周界空氣中可測得苯環數較高的Benzo(k)-floranthene(BkF)、Benzo(a)pyrene(BaP)、Dibenzo(a,h)anthracene(DBA)、Benzo[g,h,i]perylene(BghiP)和Indeo[1,2,3-cd]pyrene(InP),而在破碎收集廠的周界空氣中無法測得,表示BkF、BaP、DBA、BghiP和InP這幾種化合物可以用來作為廢塑膠熱熔工廠排煙的空氣污染物指標。在臭味濃度與粒狀污染濃度的關係上,熱熔工廠的臭味濃度增加時,總PAHs濃度也有增加的趨勢,所以利用臭味濃度的高低程度可以概略表示總PAHs濃度的高低。廢塑膠回收工廠不論處理何種物質,或是以何種方式處理,都會對工廠周界的空氣產生臭味、總懸浮微粒和PAHs的污染,所以對廢塑膠回收工廠的廠內和周界空氣品質,應該要訂定監測和管制防護的辦法。
本研究針對台灣有登記的34間回收公司之工廠中,隨機選取19間廢塑膠回收處理工廠周界進行臭氣採樣,利用環檢所公告之「臭味與異位官能測定法-三點比較式嗅袋法」來測定廢塑膠回收工廠周界的臭味濃度值。以鐵氟龍濾紙連接採樣幫浦收集工廠周界空氣中之總懸浮微粒,進而以高效能液相層析儀(HPLC)測定微粒中所含之多環芳香族碳氫化合物濃度,以了解台灣地區廢塑膠回收工廠之分布情形、周界臭味程度、空氣中總懸浮微粒濃度和微粒中所含之多環芳香族碳氫化合物濃度。
本研究測得之廢塑膠熱熔處理廠的周界下風處臭味濃度平均值±標準差為167.5±115.07,廢塑膠破碎收集廠周界下風處臭味濃度平均值±標準差為76.57±37.28,經過統計檢定後,發現兩者的臭味濃度有統計上顯著差異(P=0.013),顯示廢塑膠熱熔處理廠的熱熔排煙會明顯增加工廠周界的臭味濃度。熱熔處理廠周界空氣中之總懸浮微粒濃度介於45.62~347.23μg/m3之間,破碎收集廠的總懸浮微粒濃度介於64.44~1356.61μg/m3之間,熱熔處理廠和破碎收集廠的總懸浮微粒濃度沒有統計上顯著差異(P=0.083),但其中熱熔處理廠的工廠周界和其環境道路之總懸浮微粒濃度有統計上顯著差異(P=0.05),表示熱熔處理廠的運作確實會增加周界空氣中的總懸浮微粒濃度。
熱熔處理廠的總PAHs濃度介於8.92~25.04 ng/m3之間,破碎收集廠的總PAHs濃度介於14.48~24.06ng/m3之間,熱熔處理廠和破碎收集廠的空氣中總PAHs濃度無統計上顯著差異(P=0.45)。PAHs種類上,在熱熔處理廠之周界空氣中可測得苯環數較高的Benzo(k)-floranthene(BkF)、Benzo(a)pyrene(BaP)、Dibenzo(a,h)anthracene(DBA)、Benzo[g,h,i]perylene(BghiP)和Indeo[1,2,3-cd]pyrene(InP),而在破碎收集廠的周界空氣中無法測得,表示BkF、BaP、DBA、BghiP和InP這幾種化合物可以用來作為廢塑膠熱熔工廠排煙的空氣污染物指標。在臭味濃度與粒狀污染濃度的關係上,熱熔工廠的臭味濃度增加時,總PAHs濃度也有增加的趨勢,所以利用臭味濃度的高低程度可以概略表示總PAHs濃度的高低。廢塑膠回收工廠不論處理何種物質,或是以何種方式處理,都會對工廠周界的空氣產生臭味、總懸浮微粒和PAHs的污染,所以對廢塑膠回收工廠的廠內和周界空氣品質,應該要訂定監測和管制防護的辦法。
The total quantity of recovered plastic waste bin was about 148 thousand tons in Taiwan for the year of 2005. It is a very significant issue for the treatment of such big amount of waste. The common approach adopted in Taiwan for the treatment of the plastic waste bin is recovering and recycling. The treatment process of recycling includes melting and powdering, from which bad odor and many kinds of air pollutants will be produced. The odor makes people ailing. In addition, air emitted as a result of the melting process include several chemical compound, which includes Polycyclic Aromatic Hydrocarbons (PAHs) that is of potential health risk to people.
There are thirty four plastic waste recycling plants is registered in Taiwan. In this study nineteen plastic waste recycling plants were sampled randomly. The odor and the air total suspended particulate (TSP) sampling around perimeters of plastic waste recycling plants was performed. The odor concentration and the PAHs concentration determined by olfactometry and HPLC. The objectives is to understand the levels of odor, TSP in air, and PAHs concentration on TSP at perimeters of plastic waste recycling plants.
Those olfactometric results showed that the mean and standard deviation (mean ± SD) of the odor concentration at perimeter of melting treatment plants is about 167.5 ± 115.07, whereas the Mean ± SD of the odor concentration at perimeter of shredding and recovering plants is about 76.57 ± 37.28. It is found that there exists a statistically significant difference on odor concentrations (p = 0.013) at these two different locations, and it shows that the melting process will increase the level of odor concentration significantly. The TSP concentration at the perimeter of melting treatment plants ranges from 45.62 to 347.23 μg/m3, while this value for the perimeter of shredding and recovering plants ranges from 64.44 to 1356.61 μg/m3. There is no significant different for TSP concentrations at these two different plants plants(P = 0.083). In addition, another set of data showed that the TSP concentration at perimeter of melting treatment plants is significantly higher than that on the opposite side of the road outside melting plants (P = 0.05), and this suggests that the melting treatment does increase the level of TSP concentration.
The measured total PAHs concentration at the perimeter of melting treatment plants ranges from 8.92 to 25.04 ng/m3, while that at the perimeter of shredding and recovering plants ranges from 14.48 to 24.06 ng/m3. The difference of the total PAHs concentrations is not significant at these two types of plants (P = 0.45). In terms of separate items considered in the PAHs, Benzo(k)floranthene (BkF), Benzo(a)pyrene (BaP), Dibenzo(a,h)anthracene (DBA), Benzo[g,h,i]perylene (BghiP), and Indeo[1,2,3-cd]pyrene (InP) can be detected from the TSP at the perimeter of melting treatment plants. On the other hand, they cannot be detected from the TSP at the perimeter boundary of shredding and recovering plants. This suggests that BkF, BaP, DBA, BghiP, and InP can be used as air pollution indicators for plastic waste melting treatment plants. Regarding the correlation between the odor concentration and the total PAHs concentration at the perimeter of melting plants, it is found that the total PAHs concentration tends to be higher when the odor concentration is higher. This seems to suggest that the level of the odor concentration is sort of an indicator of the level of total PAHs concentration at the perimeter of melting treatment plants.
There are thirty four plastic waste recycling plants is registered in Taiwan. In this study nineteen plastic waste recycling plants were sampled randomly. The odor and the air total suspended particulate (TSP) sampling around perimeters of plastic waste recycling plants was performed. The odor concentration and the PAHs concentration determined by olfactometry and HPLC. The objectives is to understand the levels of odor, TSP in air, and PAHs concentration on TSP at perimeters of plastic waste recycling plants.
Those olfactometric results showed that the mean and standard deviation (mean ± SD) of the odor concentration at perimeter of melting treatment plants is about 167.5 ± 115.07, whereas the Mean ± SD of the odor concentration at perimeter of shredding and recovering plants is about 76.57 ± 37.28. It is found that there exists a statistically significant difference on odor concentrations (p = 0.013) at these two different locations, and it shows that the melting process will increase the level of odor concentration significantly. The TSP concentration at the perimeter of melting treatment plants ranges from 45.62 to 347.23 μg/m3, while this value for the perimeter of shredding and recovering plants ranges from 64.44 to 1356.61 μg/m3. There is no significant different for TSP concentrations at these two different plants plants(P = 0.083). In addition, another set of data showed that the TSP concentration at perimeter of melting treatment plants is significantly higher than that on the opposite side of the road outside melting plants (P = 0.05), and this suggests that the melting treatment does increase the level of TSP concentration.
The measured total PAHs concentration at the perimeter of melting treatment plants ranges from 8.92 to 25.04 ng/m3, while that at the perimeter of shredding and recovering plants ranges from 14.48 to 24.06 ng/m3. The difference of the total PAHs concentrations is not significant at these two types of plants (P = 0.45). In terms of separate items considered in the PAHs, Benzo(k)floranthene (BkF), Benzo(a)pyrene (BaP), Dibenzo(a,h)anthracene (DBA), Benzo[g,h,i]perylene (BghiP), and Indeo[1,2,3-cd]pyrene (InP) can be detected from the TSP at the perimeter of melting treatment plants. On the other hand, they cannot be detected from the TSP at the perimeter boundary of shredding and recovering plants. This suggests that BkF, BaP, DBA, BghiP, and InP can be used as air pollution indicators for plastic waste melting treatment plants. Regarding the correlation between the odor concentration and the total PAHs concentration at the perimeter of melting plants, it is found that the total PAHs concentration tends to be higher when the odor concentration is higher. This seems to suggest that the level of the odor concentration is sort of an indicator of the level of total PAHs concentration at the perimeter of melting treatment plants.