摘要

表面電漿波共振(surface plasmon resonance)生物感知器具有即時(real time)偵測、高靈敏度以及不需螢光物標定(label-free)等優點,可作為極低濃度的生物分子識別與其反應動力學之用。然而,目前傳統SPR生物感知器的靈敏度僅能達到 ,為改善此一缺點,本實驗提出成對式表面電漿波生物感知器(paired surface plasma wave biosensor;PSPWB),結合外差干涉光共路徑及振幅相除(amplitude-ratio)模式,使PSPWB具有以下特性:(1)兩對同調性(coherence)相關且正交的線性極化光,具有相同拍頻(beat frequency) 作為外差干涉訊號來源;(2)只有P-wave才會產生SPW,P-wave為訊號端,以S-wave做為參考端,訊號處理以振幅相除法(amplitude-ratio algorithm)表示;(3)外差干涉為基礎,P-wave及S-wave為共光路徑,成對的P-wave與S-wave具有高度空間(spatial)與時間(temporal)相關性,因此可提高偵測靈敏度及更廣的量測動態範圍(dynamic range)。本研究使用蔗糖溶液及甘油溶液來偵測系統靈敏度,蔗糖溶液的最低可量測濃度為0.001wt.%,相對的折射率變化達到10-7RIU(refractive index unit);量測生物分子mouse IgG/anti-mouse IgG交互作用,最低可量測濃度為10pg/ml,偵測靈敏可達10-9RIU。本研究中另外使用奈米金粒子(□=20nm)增強訊號量測靈敏度。藉由奈米金粒子在感測層造成的折射率變化以及本身的局部表面電漿波(localized surface plasmon)作用與原本在金屬層的表面電漿波之加成效果,使偵測靈敏度大幅提升,實驗中已可量測到0.33pg/ml的20nm奈米金粒子相接的protein A與mouse IgG的結合信號,此實驗結果證明此感測平台已具有足夠的靈敏度應用於蛋白質生醫環境的微量測量上。
蛋白質聚合化在生物體內佔有一重要的生理功能,包括有細胞分裂、肌肉收縮等,而另外對疾病如阿茲海默症、庫賈氏症等不正常聚合化造成的致病來源佔有重要的機轉意義。球形肌動蛋白(G-actin;globular actin)聚合化過程依循核心化 (nucleation)與延展 (elongation)兩大步驟,其中核心化為一速率限制的過程,本研究中將使用未聚合化的G-actin以及已經聚合化的纖維肌動蛋白(F-actin;filamentous actin)的聚合化動力學,推得G-actin核心化的臨界濃度為0.48□M,而F-actin因已有成核的纖維束,量測的濃度範圍內沒有延遲期,臨界濃度可能低於量測濃度。細胞的肌動蛋白骨架是否能因應外界訊號的刺激而產生重組,將影響該細胞在受到這些刺激時能否適時產生形狀改變、移動、胞內的訊號傳遞,甚至會影響存活,因此提供肌動蛋白在聚合過程的資訊將顯得重要。
Surface plasmon resonance (SPR) biosensor is capable of high sensitivity、real-time detection and label-free technique to monitor the binding events of molecules. In this study, a novel SPR biosensor, paired surface plasma wave biosensor (PSPWB) is set up, which generates a pair of surface plasmon waves (SPWs) simultaneously on the interface of metal/medium of sensor chip able to enhance the sensitivity of detection up to RIU (refractive index unit). PSPWB not only produces high detection sensitivity but also provides a large dynamic measurement range on effective refractive index (Δneff) based on this novel amplitude-sensitive detection method. The experimental results verify the advantages of PSPWB that performs up to 10-7 RIU on sensitivity by measuring a 0.001wt% sucrose solution successfully. In order to further enhance the detection sensitivity of PSPWB, 0.33pg/ml (7fM) of gold nanoparticle particle conjugated protein-A (PA-Au) interacts with mouse IgG was detected successfully.
Thereafter, this PSPWB is applied extensively to investigate the spontaneous polymerization of actin monomers in real time, which obeys a two-stage process including nucleation and elongation. When the concentration of globular actin (G-actin) below a critical concentration, the polymerization rate of G-actin is slow which means that the association rate and dissociation rate is equivalent. Once the concentration of G-actin exceeds over the critical concentration, the polymerization rate will increase apparently. In this study, the polymerization kinetics of the G-actin and F-actin were measured. Without the influence of cap protein, the critical concentration of G-actin is 0.48□M from the measurement of kinetics assay of G-actin.
顯示完整詮釋資料 統計資料

引用此條目

陳怡伶 (2006). 成對表面電漿波生物感知器量測靈敏度之評估. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/33162

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/33162