利用溫度變化梯度偵測靜脈注射之外滲

Detecting Extravasation via Temperature Variation

檔案

本條目沒有附加檔案。

日期

2006

類型

語言

中文

摘要

本研究目的是在研製一套靜脈注射輸液幫浦的外滲液偵測系
統。係利用溫度感測技術即時監控皮膚表面溫度,若注射液外滲至血
管外,會造成皮膚表面溫度下降,從而偵測其溫度變化,就得以偵測
靜脈注射液外滲的情形。
當靜脈注射發生外滲時,剛開始病人不會有感到異常的感覺,等
到注射部位疼痛腫脹時、經常會造成組織壞死,嚴重者甚至需要作肢
體切除和整形外科手術。尤其對疼痛忍受度高的病人來說,若等到病
人感覺疼痛難耐時,可能已經造成嚴重的傷害,至於對不會表達的植
物人與嬰兒,情況將更為嚴重,因此若可以提早發現外滲情況,就可
以避免傷害的持續擴大。
人的手臂皮膚溫度約33℃,在醫院的環境中靜脈輸液溫度約
20-23℃,當靜脈輸液正常注射於血管內,血流可以快速的將低溫液
體帶走,一旦發生外滲,冷液體會累積於血管外組織間,造成局部組
織溫度下降。因此,可以利用溫度感測器監控組織溫度變化,當發現
組織溫度異常下降,由系統判別是否為靜脈輸液外滲至組織,若判別
為外滲則立刻停止點滴精密輸液幫浦的運作,並發出警報通知醫護人
員處理。
在本研究中,我們以猪隻進行動物實驗,結果顯示在注射速率
25、50、75、100ml/hr 的情況下,外滲的溫度與正常注射的溫度皆
有統計上的顯著差異,利用溫度梯度可以在外滲量小於2.2ml 測得外
滲情況,證實了溫度感測技術可以應用於靜脈注射外滲偵測。
The purpose of this research is to establish outter leakage detection
system for intravenous infusion pump. If the infusion oozes out of blood
vessel, it will cause the tissue temperature dropped. Therefore, this
research utilizes temperature detection technology to monitor tissue
temperature. When the temperature drops exceed a predetermined
threshold, the system will shutdown and alarm for medical-aid attention.
When infusion leakage happens, patient will feel pain and swollen at
the injection site. Moreover, it will cause tissue necrotise. For some
severe cases, patient will have to amputate the limbs. For those who has
more toleration on pain, the leakage would cause severe injury when the
patient felt that the pain was unable to endure. As can be expected, this
situation worsen on the vegetable or the infant who cannot express
themselves well.
Human arm skin temperature is around 33℃ and the intravenous
injection fluid in the hospital is around 20~23℃. Therefore, when the
fluid is properly injected into the vessel, the blood can wash away the low
temperature fluid. However, when the leakage occurs, the fluid will
accumulate and will cause a temperature drop at the location between the
skin and vessel. Thus, a sensitive thermal detector could detect the
temperature variation. When the temperature drop exceeds a predefined
threshold, the system would determine that it is an intravenous injection
10
leakage. And it will stop the intravenous drip, and set off alarm to notify
the medical staff.
In this research, we utilize pigs to do the animal test. These results
show that under infusion speed of 25, 50, 75 and 100 ml/hr, the
extravasation temperature and normal infusion temperature all have
significantly difference. Therefore, temperature extravasation detection
system can detect the leakage under 2.2ml of leaking. In concolusion,we
suggest that the temperature sensing technology maybe apply in low flow
speed vein infusion extravasation detection.
顯示完整詮釋資料 統計資料

引用此條目

葉展良 (2006). 利用溫度變化梯度偵測靜脈注射之外滲. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/33176

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/33176