以光纖生物感測器研究急性心肌梗塞中mCRP/anti-CRP間交互作用之動力學量測

The Application of Fiber-Optic Biosensor on Measuring Kinetics of mCRP/anti-CRP interaction for Acute Myocardial Infarction Detection

檔案

全文未公開。

日期

2005

類型

語言

中文

摘要

急性心肌梗塞影響我國國民健康日益嚴重,由於動脈硬化造成輸送至心臟的血管發生阻塞,使得心肌無法獲得足夠的氧氣和養分供應而損傷,如果能在愈短的時間內正確地診斷出急性心肌梗塞,將使心肌受傷面積愈小,有助於病人預後情況。
本實驗室架設的光纖生物感測器,運用三明治酶聯法將CRP的抗體固定在去纖衣的光纖表面上,之後與其特異性抗原以及螢光標誌抗體做特異性結合形成<anti-CRP/mCRP/FITC-anti-CRP>三明治複合體。利用488nm雷射光在光纖內進行全反射傳播所產生之瞬逝波,其能量會隨著距纖核表面距離增大而逐漸衰減的原理,運用瞬逝波激發距離光纖表面幾佰奈米範圍內形成三明治複合體上的FITC,產生波長為 之螢光,由架設於反應腔側端之光電倍增管接受螢光訊號的及時測量及分析。
本實驗成功地以IgG/anti-IgG作為前導實驗,也針對pCRP與mCRP作定性之動力學常數測量及分析。本實驗可即時量測mCRP/anti-CRP的分子交互作用及動力常數,由於偵測範圍限制在光纖表面,只有真正參與反應的生物分子其螢光會被激發,故可以省略清洗未與抗原反應之螢光抗體的步驟,不但使量測的過程更為簡便以及快速,更可在抗體抗原反應過程中作即時監測,觀察抗體抗原結合動力學的反應。
Acute myocardial infarction (AMI) is one of the most common disease in industrialized countries and now is becoming an serious problem in developing countries. AMI occurs when a coronary blood flow decreases abruptly after a thrombotic occlusion of a coronary artery previously narrowed by atherosclerosis. In this research, a novel fiber-optic biosensor which can quickly diagnose AMI at early stage is developed and tested.
In this study, a fiber-optic biosensor which an antibody immobilized on the unclad region of a plastic fiber captures its antigen, and then FITC labeled antibody form <Ab/Ag/FITC-Ab> complex of the sandwich structure. The setup with a laser beam of its wavelength at 488nm which propagates in a multi-mode optic excites the evanescent wave penetrates the surface of the unclad fiber. The evanescent wave enables to extends several hundred nanometers in depth into the dielectric medium near unclad surface and excites the FITC molecules. The emitted fluorescence (520nm) is collected by use of a photomultiplier tube set aside to the reaction chamber, in order to emphasis the fluorescence collection efficiency.
In the experiment, a IgG/anti-IgG interaction to measured that the kinetic coefficients, , and are obtained successfully. Then we applied this method to analyze pCRP and mCRP interaction with anti-CRP respectively. The results show that the equilibration dissociated constant of <mCRP/anti-CRP> interaction is few times larger than that of <pCRP/anti-CRP> which represents a specificity of mCRP to anti-CRP experiments.Therefore, this fiber-optic biosensor can compare the method to other techniques, our developed system has rapid, simple, and real-time detection capabilities at the same time. Furthermore, it can be used for clinical application in the specified protein detection on early detection of different diseases. In the mean time, this biosensor can provide the method for protein interaction measurement in real time on new drug development as well.

所屬典藏

生醫光電研究所
顯示完整詮釋資料 統計資料

引用此條目

陳香吟 (2005). 以光纖生物感測器研究急性心肌梗塞中mCRP/anti-CRP間交互作用之動力學量測. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/33209

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/33209