海軍艦艇應用細水霧滅火效能之探討
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
陳俊勳 | |
dc.contributor.advisor |
Chiun-Hsun , Chen | |
dc.contributor.author |
隋增輝 | |
dc.contributor.author |
Tseng-Hui , Sui | |
dc.contributor.college |
工學院 | |
dc.contributor.committee |
||
dc.contributor.committee |
||
dc.contributor.department |
工學院精密與自動化工程學程 | |
dc.contributor.studentid |
9369523 | |
dc.date.NCLavailable |
不公開 | |
dc.date.USTavailable |
不公開 | |
dc.date.issued |
2007 | |
dc.date.issuedROC |
96 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
95 | |
dc.description.abstract |
過去歷次艦艇所發生之火災均造成相當程度的損失,是以如何在火災初期即有效撲滅火勢與控制煙霧擴散,以確保航安、人安與物安乃為本研究之重要課題。細水霧系統因具有諸如:較好之火災抑制能力、煙霧吸附力、較低的水損、無毒、安全及環保等優點,導致海龍(Halon)滅火系統於蒙特婁公約(Montreal Protocol)簽署實行而中止使用後,獲得全世界一致認同。 此外由於電腦的運算速度突飛猛進、硬體價格下滑、性能式設計興起,以及火場電腦模擬技術漸趨成熟等因素,使得電腦模擬成為評估防火功能與火場模擬的最佳工具。依照實際環境之特性與條件,透過電腦數值模擬之方式模擬不同的危害情境,並依據分析結論訂定妥善之防(滅)火與救災計畫,除可節約實體驗證的時程與成本外,亦可提升艦艇火災安全防護能力,使火損與煙損降至最低程度,確保海上航行安全。 電腦模擬為非常適合用以驗證細水霧系統功能及效益性的工具,在本論文裡,使用電腦模擬平台來驗證細水霧系統在艦艇輪機主要艙間之應用,由模擬的結果得知,細水霧滅火系統於自然通風或強制通風的狀態下均可有效抑制火災,另相較於海軍艦艇其它現行之滅火系統,其火災抑制效能亦較為優異。 | |
dc.description.abstract |
In the past, all previous fire taken place of naval ships caused intolerable loss cost. So how to put out the intensity of a fire effectively in initial stage and control the smog to spread, in order to really guarantee navigation, personal and equipment safety is an important subject of this thesis. Because of water mist system providing the following advantages over other suppression systems, such as superior fire suppression, smoke absorption capability, minimal water damage, non-toxicity, safety and environmentally friendly, it has gained worldwide acceptance as an effective solution in many applications after the phase out of Halon production under the Montreal Protocol. In addition, because calculating speed of computer advance by leaps and bounds, hardware price goes down, PBD(Performance-Based Design) concept is rising, and computer modeling simulation technology getting maturity, those make computer modeling become an effective tool to evaluate the fire-proof function and simulate fire scenario. According to the characteristic and condition of the real environment, the computer can simulate different type of disasters by the way of numerical simulation and stipulate an appropriate fire protection and disaster relief plan following the conclusion. It’s not only save time and cost of physical test and evaluation, but also improves naval ship’s capability of fire protection which makes the lose cost of fire drop to the minimum degree and guarantee the maritime navigation safety. Computer simulation is a suitable tool to identify the systematic function and benefit of water mist system. In this thesis, we use computer simulation platform to prove the possibility of application of water mist system in naval ship’s main machinery spaces. According to the results of simulation, water mist system can suppresses the fire effectively under the situation of non- ventilation or forced ventilation. Another looks, relatively in other current fire extinguishing systems of naval ship, it is also comparatively excellent that its fire suppresses efficiency. | |
dc.description.abstractopendate |
||
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
中文摘要................................................i英文摘要.............................................ii~iii誌謝....................................................iv目錄.................................................v~viii圖目錄..................................................ix~xiv表目錄..................................................xv第一章 緒論......................................................11.1 研究動機與目的......................................11.2 研究範疇............................................41.3 文獻探討............................................61.4 研究方法與流程.....................................12第二章 現行艦艇滅火系統能量比較與探討..................172.1 火災基本概念.......................................172.2 滅火系統應用限制...................................182.3 滅火能量分析.......................................192.4 細水霧滅火系統原理.................................212.5 細水霧噴撒特性.....................................252.6 各類型滅火系統之優劣比較分析.......................28第三章 電腦數值模擬介紹................................363.1 FIREDASS...........................................383.2 FDS................................................40第四章 電腦數值模擬驗證................................444.1 無滅火系統作動狀況之火災情境模擬...................464.2 固定式50磅二氧化碳滅火系統效能評估.................484.3 撒水系統滅火系統(密閉狀態)效能評估...............504.4 撒水系統滅火系統(開口與強制通抽風狀態)效能評估...524.5 細水霧滅火系統(密閉狀態)效能評估.................544.6 細水霧滅火系統(開口與強制通抽風狀態)效能評估.....55第五章 結論與建議......................................615.1 結論...............................................615.2 建議...............................................62參考文獻...............................................65 | |
dc.identifier.citation |
1. 鄧子正,“火災科學的基本概念",初版,中央警察大學出版社,(1999)pp.202~211.2. Montreal Protocol Meeting Concludes, Media Note, Office of the Spokesman, Washington, DC, March , 1947.3. Http://www.tycofis.co.uk/, Fire & Integrated Solutions.4. IMO Res.A.800: "Revised Guidelines For Approval of Sprinkler Systems Equivalent in that Referred to in SOLAS Regulation ",Ⅱ-2/12, International Maritime Organization, 1992.5. Robert L. Darwin, Frederick W. Williams, “Overview of the Development of Water-Mist Systems for US Navy Ships”, Halon Options Technical Working Conference, 1999, pp.373~380.6. NFAP 325, “Guide to Fire Hazard Properties of Flammable Liquids , Gases, and Volatile Solids,” 1994.7. Wighus, R., “Extinguishment of Enclosed Gas Fires with Water Spray,” Proceeding of the Third International Symposium of Fire Safety Science, 1991.8. Williams, F.W., Back, G.G., DiNenno, P.J., Darwin, R.L., Hill, S.A., Havlovick, B.J., Toomey, T.A., Farley, J.P., and Hill, J.M., “Full-scale Machinery Space Water Mist Tests: Final Design Validation, “ NRL/ MR/6180-99-8380, Naval Research Laboratory, Washington, DC, June 12, 1999.9. Purdue University (1950), Purdue Research Foundation and Department of Chemistry, "Final Report on Fire Extinguishing Agents for the Period 1 September 1947 to 30 June 1950," WestLafayette, IN, U.S.A.10. Joseph Santillo,"Remove five Halon 1301 systems and furnish and install five HFC 227ea systems at Tobyhanna Army Depot, Tobyhanna, PA".DAAB17-02-B-0004, U.S. Army Materiel Command, U.S. Army Communications-Electronics Command, Tobyhanna Depot Contracting Office. 2002.11. Wickham, Robert. T, “Status of Industry Efforts to Replace Halon Fire Extinguishing Agents”, Wickham Associates, Stratham, NH: March 2002.12. "NFPA 750 2000 edition: Standard on Water Mist Fire Protection Systems", National Fire Protection Association, Quincy, MA, 2000.13. Braidech, M.M., Neale, J.A., Matson, A.F. and Dufour, R.E. “The Mechanisms of Extinguishment of Fire by Finely Divided Water”, Underwriters Laboratories Inc. for the National Board of Fire Underwriters, NY, pp.73.14. Mawhinney, J.R., Dlugogorski, B.Z. and Kim, A.K. “A Closer Look at the Fire Extinguishing Properties of Water Mist”, Fire Safety Science-Proceedings of Fourth International Symposium, Ottawa, ON, pp.47.15. Back, G.G., DiNenno, P.J., Leonard, J.T and Darwin, R.L., ”Full Scale Tests of Water Mist Fire Suppression Systems for Navy Shipboard Machinery Spaces Part II- Obstructed Spaces,” Naval Research Laboratory, NRL/MR/6180-96-7831, 199616. Hansen, R., “Local Application of Water Mist for Machinery Protection,” Proceedings: Halon Alternatives Technical Working Conference, Albuquerque, New Mexico, 1998, pp.439.17. Pepi, J.S., ”Advance in the Technology of Intermediate Pressure Water Mist Systems for the Protection of Flammable Liquid Hazards” Proceedings: Halon Alternatives Technical Working Conference, Albuquerque, New Mexico, 1998, pp.417.18. Dundas, R.E, “Experience with External Fires in Gas Turbine Installations and Implications for Fire Protection,” ASME Paper No:90-GT-375,1990.19. Hanauska, C.P., and Back, G.G “Halons: Alternative Fire Suppression Systems, An Overview of Water Mist Fire Suppression Systems Technology,” Hughes Associates, Inc., Columbia, MD, 199320. Liu, Z.G., Kim, A. K. Su J. Z. “Examination of Performance of Water Mist Fire Suppression System under Ventilation Conditions” Journal of Fire Protection Engineering, v.11, no.3, August 2001, pp. 164 -193.21. Will Koroluk “Tests Show Effectiveness of Cycled Discharge from Water Mist Fire Protection Systems” Published in CABA home & Building Automation Quarterly, 1998, pp.28-29.22. Kim, A “Overview of Recent Progress in Fire Suppression Technology ” Invited Keynote Lecture at the 2nd FRIFD Symposium, Proceedings, Tokyo, Japan, July 17-19, 2002, pp.1-13.23. Liu, Z.G.; Kim, A.K.; Su, J.Z. "Examination of Performance of Water Mist Fire Suppression Systems under Ventilation Conditions".NRCC-44676, National Research Council Canada,1997.24. Alpert, R L., “Numerical Modeling of the Interaction Between Automatic Sprinkler Sprays and Fire Plumes”. Fire Safety J., 9(1985), pp. 157-163.25. A. Jones and P.F. Nolan” Discussions on the use of fine water spray or mists for fire suppression” J.Loss Prev Ind., 1995, Volume 8,Number 1.26. Myung Bae Kim, Yong Jae Jang &Jin KooK Kim “Extinction Limint of a pool Fire with a Water Mist” Fire Safety Journal 28(1997), pp. 295 -306.27. Kondo, T., Mori, N., Noguchi, Y., and Tokuoka, N., "Fire Extinction by Water Spray", Proceedings of ILASS-Asia, 2001, pp.34-38.28. Robert, L.D., Frederick W. W., “Overview of the Development of Water-Mist Systems for U.S Navy Ships”, Halon Options Technical Working Conference, 1999, pp.373~380.29. Hills A. T., Simpson T., Smith D. P., ”Water Mist Fire Protection for Telecommunications Switch Gear and Other Electronic Facilities.”, NIST, 1993.30. K. Kailasanath, D Schwer, G. Patnaik, “An Advanced Simulation Tool for Damage Assessment, NRL Review200, 2002.31. Http://www.dnv.com, “Engine Room Fires Can Be Avoided”, Det Norske Veritas, Norway, 2000.32. Mike E., Steve W., James G., “Low-Pressure Water Mist, Fine Water Spray, Water Source, and Additives: Evaluation for the Royal Navy”, Halon Options Technical Workings Conference, 1999, pp. 381-394.33. Drysdale, D.,” An Introduction to Fire Dynamics,” John Wiley and sons, Chichester, UK, 1985.34. M. Edwards, S. Watkins, Dr. J. L. D. Glockling, “Development of a Water Based Fire Suppression System for Naval Fighting Ships”, DoD paper, 1999.35. NAVSEA, “Surface Ship Firefighting”, NSTM CH. 551 V1, U.S. NAVY, pp. 20-195.36. Http://www.fike.com/, “Water Mist for Machinery Spaces”, Fike Corporation.37. Mawhinney J.R., Dlugogorski B.Z., Kim A.K., “Closer Look at the Extinguishing Properties of Water Mist”, International Association for Fire Safety Science – Proceedings of Fourth International Symposium, 1994, pp. 47-60.38. Rosander, M. and Giselsson, K., “Making the Best Use of Water for Fire Extinguishing Purposes”, Fire, Oct., 1984, pp. 43-46.39. Mawhinney, J.R., “Characteristics of Water Mists for Fire Suppression in Enclosures”, International Conference on Water Mist Fire Suppression Systems, Sweden, 1993.40. Http://www.msc.navy.mil/, “Water Mist Fire Suppression System Part Ⅱ”, 30 September 1997.41. Rasbash, D.J., “Extinction of Fire with Plain Water: A Review”, Proceedings of the First International Symposium on Fire Safety Science, Hemisphere Publishing Corporation, 1986,pp. 1145-1163.42. Notarianni K. A. "Water Mist Fire Suppression Workshop Summary "Gaithersburg, MD, 1-2 March, NIST, 1993.43. Lefebvre, A. H. , Atomization and Sprays, Hemisphere Publishing Corporation,1989.44. Andrews, S.P., “Literature Review: Fire Extinguishing by Water Sprays”, Building Research Establishment, UK, Internal Report, 1992.45. Dougogorski B. Z., J. R. Mawhinney, A. K. Kim and G Crampton,unpublished laboratory data, National Fire Laboratory, National Research Council Canada, Ottawa, 1994.46. Http://www.msc.navy.mil/, “Water Mist Fire Suppression System Part Ⅰ”, 19 September 1997.47. John, M., Watts Jr., “ Probabilistic Fire Models,” by A.E. Cote & J. L. Linville et al., Fire Protection Handbook, 18th edition, National Fire Protection of Association, Section 11/Chapter 6, pp. 11-62~11-70, (1997).48. William, D. Walton and Edward K. Budnick, “ Deterministic Computer Fire Model,” by A.E. Cote &J.L. Linville et al., Fire Protection Handbook, 18th edition, National Fire Protection of Association, Section 11/Chapter 5, pp.11-52~11-62, (1997).49. Grandison A. J., Mawhinney R. N., Galea E. R., Patel M. K., “The FIREDASS (FIRE Detection And Suppression Simulation) MODEL”, Fire Safety Engineering Group.50. Http://www.sintef.no/, “Fire Detection and Suppression Simulation -FIREDASS”.51. 徐一量,“火場模擬技術手冊",工研院環安中心,民國90年12月。52. 劉維義,“電腦數值模擬在細水霧滅火效能之應用與探討",國立交通大學產業安全與防災學程碩士論文,民國94年1月。53. “Revised IMO Test Protocol – MSC/Circ. 668R”, The 49th meeting of the Fire Protection Sub-Committee of the International Maritime Organization, Jan. 2005.54. “Draft British Standard Code of Practice for the Application of Fire Safety Engineering Principles to Fire Safety in Buildings”, Warrington Fire Research Consultants, 1993.55. 劉祥輝,“消防工程手冊–理論與實際",初版,全華科技圖書股份有限公司,(2003)pp. 9.1~9.18 | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/34331 | |
dc.language.iso |
中文 | |
dc.relation.alma |
990010417290206772 | |
dc.relation.page |
132 | |
dc.subject.keyword |
海軍艦艇 | |
dc.subject.keyword |
電腦模擬 | |
dc.subject.keyword |
FIREDASS | |
dc.subject.keyword |
FDS | |
dc.subject.keyword |
Naval Ship | |
dc.subject.keyword |
Computer Simulation | |
dc.subject.keyword |
FIREDASS | |
dc.subject.keyword |
FDS | |
dc.title |
海軍艦艇應用細水霧滅火效能之探討 | zh-TW |
dc.title |
Efficiency Discussion of Water Mist Fire Suppression Application in Naval Ship | en |
dc.type |
Thesis | zh-TW |
檔案
全文未公開。