空氣中無機酸氣體及微粒檢測方法研究

Study on Methods for Measuring Inorganic Acid Gases and Particles in Air

檔案

全文將於 2029年8月25日 起公開。

日期

2024

類型

語言

中文

摘要

Inorganic acids are crucial industrial raw materials with high corrosiveness. When released into the air, they can harm health, damage ecosystems, and corrode metal equipment. Monitoring their concentration is essential for preventive measures. Silica gel tubes are commonly used due to their simplicity, efficiency, cost-effectiveness, and portability, but they have drawbacks like high background values and low aerosol collection efficiency. NIOSH recommends the filter method, which retains the advantages of silica gel tubes while offering lower detection limits and background values, and can separately collect particles and gases. The impinger method uses liquid to collect gases and particles simultaneously, improving on the high blank background values and detection limits of silica gel tubes.
This study compares the feasibility of the filter method and the impinger absorption method for detecting six types of inorganic acids (HF, HCl, HBr, HNO3, H3PO4, and H2SO4) in ambient air, aiming to propose alternatives to silica gel tubes.
Results show that the MDLs of both methods are much lower than those of silica gel tubes and meet perimeter control standards. In the laboratory, the collection efficiency was evaluated by spiking samples and simulating actual sampling. The recovery of the six inorganic acids using the filter method was 88.1 % to 104.7 %, with a standard deviation of 0.35 % to 5.40 %, and a penetration rate of <10 %, indicating good collection efficiency. The impinger method was tested using KOH and DI water as absorption solutions, showed low collection efficiency for HCl and H2SO4 but had a recovery of 75.59 % to 105.81 % for the other four acids, with a standard deviation of 0.29 % to 6.80 %, and a penetration rate of <10%. Field tests showed the filter method had better four efficiency than the impinger method. The study concludes that the filter method is more suitable for detecting inorganic acids in ambient air.
無機酸為重要的工業原物料,具有高度腐蝕性,排放至周界環境後,可能危害居民健康、破壞生態環境以及腐蝕金屬設備,因此需要以檢測技術掌握周界環境中無機酸濃度,作為制定防治措施的參考。各項無機酸檢測技術中,矽膠管法具有操作簡單、捕集率好、經濟、輕便等優點而被廣泛使用,然而亦存在空白背景值高、氣膠捕集率偏低以及偵測極限高等缺點。美國國家職業安全衛生研究所針對勞工作業場所提出濾紙捕集法取代矽膠管法,保留了矽膠管簡單經濟的優點,並提供更低的偵測極限及更低的濾紙空白背景值,且能將微粒及氣體分別捕集。衝擊瓶法是以液體同時捕集氣體及微粒,保留矽膠管優點且改善空白背景值及偵測下限高等缺點。
本研究目的為針對周界空氣中HF、HCl、HBr、HNO3、H3PO4及H2SO4等六種無機酸,研究及比較濾紙捕集法與衝擊瓶吸收法於檢測周界空氣中無機酸的可行性與適用性,提出取代矽膠管的檢測方法建議。
方法偵測極限(MDL)評估結果,濾紙法及衝擊瓶法對於六種無機酸的MDL,皆遠低於矽膠管法以及周界管制標準,顯示兩種檢測方法的參數條件皆可滿足周界管制標準評估需求。實驗室內以添加樣品並模擬實際採樣評估捕集效果,濾紙法六種無機酸的添加回收率平均值88.14 % ~104.74 %,標準差0.35 % ~ 5.40 %,穿透率皆< 10 %,顯示捕集效果良好;衝擊瓶法使用KOH及去離子水兩種吸收液進行測試,HCl及H2SO4結果顯示捕集效果不佳,其他四種無機酸平均回收率75.59 % ~ 105.81 %,標準差0.29 % ~ 6.80 %,穿透率皆< 10%。實場添加回收率測試,濾紙法在周界環境中捕集效果尚可接受,而衝擊瓶法誤差範圍及變異性大幅上升。因此本研究結論為,針對周界環境的空氣中無機酸檢測技術,兩種檢測方法中以濾紙捕集法較為適用。
顯示完整詮釋資料 統計資料

引用此條目

吳佩玲 (2024). 空氣中無機酸氣體及微粒檢測方法研究. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/3515