可調式頻寬/增益之四通道生理訊號擷取晶片設計
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
林進燈 | |
dc.contributor.author |
戴毓廷 | |
dc.contributor.author |
||
dc.contributor.college |
電機學院 | |
dc.contributor.committee |
||
dc.contributor.committee |
||
dc.contributor.department |
電控工程研究所 | |
dc.contributor.studentid |
9412636 | |
dc.date.NCLavailable |
2013/08/18 | |
dc.date.USTavailable |
2013/08/18 | |
dc.date.issued |
2008 | |
dc.date.issuedROC |
97 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
96 | |
dc.description.abstract |
在人體所有的生理訊號中,其訊號振幅皆非常微弱,亦容易被受測者本身、量測環境及設備等因素所影響,故本論文提出適用於各種電生理訊號擷取之晶片設計。除了一般著重的低功率、低雜訊之外,同時提高共模訊號拒斥比(CMRR)與電源漣波拒斥比(PSRR),並將整體多通道前端電路整合實現在單一晶片上,不需要任何外接元件,除了兼具成本與晶片面積效益,亦可降低因複雜的接線對生理訊號在量測時所造成的干擾,使後端處理及分析的訊號品質能夠更為精確。另外,在系統加入了數位控制介面,根據不同生理訊號的需求,利用數位訊號去控制選擇所要的訊號放大倍率與系統頻寬。 本論文所設計的生理訊號擷取晶片包含:電流平衡式儀表放大器(CBIA)、類比多工器、切換式電容低通濾波器(SCLPF)、非重疊時脈產生器(Non-Overlapping Clock Generator)及可程式增益放大器(PGA)等電路。整個電路設計使用TSMC 0.18μm CMOS 1P6M 製程技術來實現,而整體晶片面積為0.823×0.953 。由模擬結果顯示,在頻率150Hz下,可獲得CMRR 135dB、PSRR+ 105dB,和PSRR- 112dB的效能。在操作電壓 0.75V下,總消耗功率約112.68μA,平均每一通道消耗功率約28.17μA。 | |
dc.description.abstract |
Due to properties of low-amplitude and non-stationary, most of biomedical signals are easily influenced by examined persons, measured environment, and electronic devices. A novel analog circuit design is proposed in this thesis, which is suitable for various biomedical signal acquisitions. In addition to the consideration of low power and low noise, the multi-channel analog front-end integrated circuit (AFEIC) is designed with high common-mode rejection ratio (CMRR) and high power supply ratio (PSRR). This circuit is realized into a single chip without any external component. It can not only reduce the number of outer components, but also enhance a better signal-to-noise ratio enormously. In addition, to select system gain and bandwidth corresponding to different amplitude and frequency of biomedical signals, the controllable digital interface was also designed and integrated into AFEIC. In this thesis, AFEIC design is composed of four current-balancing instrumentation amplifiers (CBIA), one analog multiplexer, one switched-capacitor low-pass filter (SCLPF), one non-overlapping clock generator, and one programmable gain amplifier (PGA). These circuits have been integrated into a single chip of the total area of 0.823×0.953mm2 by using TSMC 0.18μm COMS Mixed-Signal RF General purpose MiM Al 1P6M 1.8&3.3V process. For the simulation results, the proposed chip can achieve 135dB of CMRR, 105dB of PSRR+, and 112dB of PSRR- at 50Hz. The total power consumption is about 112.68□W under □0.75V supply, and the power consumption is about 28.17□W per channel. | |
dc.description.abstractopendate |
||
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
中文摘要 iiAbstract iii誌 謝 ivContents vList of Tables viiList of Figures viiiChapter 1 Introduction 11.1 Background 11.2 Motivation 31.3 Thesis Organization 6Chapter 2 Development and Critical Issue of Analog Front-End Integrated Circuit 72.1 Current-Balancing Instrumentation Amplifier (CBIA) 72.2 Rail-to-Rail Instrumentation Amplifier 112.3 AC Coupled Chopped Instrumentation Amplifier 152.4 Critical Issues Concerning the Design of a High Performance Analog Circuit 222.4.1 Noise 222.4.2 Power Consumption 26Chapter 3 Tunable Bandwidth and Gain Circuit Design of Four-channel Bio-Signal Acquisition 283.1 System Architecture 283.2 Circuit Design 303.2.1 Current-Balancing Instrumentation Amplifier (CBIA) 313.2.2 Analog Multiplexer 373.2.3 Switched-Capacitor Low-Pass Filter (SCLPF) 383.2.4 Programmable Gain Amplifier (PGA) 453.2.5 Wide-Swing Constant-Gm Cascode Biasing Circuit 483.3 AFEIC Pre-Layout Simulation 49Chapter 4 Chip Implementation, Verification and Test Platform 544.1 Design Flow 544.2 Layout Consideration and Implementation 554.3 Post-Layout Simulation 614.3.1 Chip Post-Layout Simulation 614.3.2 Manufacture Variation Post-Layout Simulation 664.3.3 Temperature Variation Post-Layout Simulation 674.3.4 Power Supply Variation Post-Simulation 684.4 Specification Comparison 684.5 Test Platform Design 714.5.1 Chip Pins Instructions and Signal Illustration 724.5.2 Test Platform Architecture 73Chapter 5 Conclusions 755.1 Conclusion 755.2 Future Work 75Reference 76Appendix 80A. DRC Verification 80B. LVS Verification 81C. Tapeout Review Form 83 | |
dc.identifier.citation |
[1] Chan, P.K.; Ng, K.A.; Zhang, X.L., "A CMOS chopper-stabilized differential difference amplifier for biomedical integrated circuits," Circuits and Systems, 2004. MWSCAS '04. The 2004 47th Midwest Symposium on , vol.3, no., pp. iii-33-6 vol.3, 25-28 July 2004.[2] Martins, R.; Selberherr, S.; Vaz, F.A., "A CMOS IC for portable EEG acquisition systems," Instrumentation and Measurement, IEEE Transactions on , vol.47, no.5, pp.1191-1196, Oct 1998.[3] Koli, K.; Halonen, K.A.I., "CMRR enhancement techniques for current-mode instrumentation amplifiers," Circuits and Systems I: Fundamental Theory and Applications, IEEE Transactions on [see also Circuits and Systems I: Regular Papers, IEEE Transactions on] , vol.47, no.5, pp.622-632, May 2000.[4] Shojaei-Baghini, M.; Lal, R.K.; Sharma, D.K., "An ultra low-power CMOS instrumentation amplifier for biomedical applications," Biomedical Circuits and Systems, 2004 IEEE International Workshop on , vol., no., pp. S1/1-S1-4, 1-3 Dec. 2004.[5] Maryam Shojaei-Baghini; Rakesh K. Lal; Dinesh K. Sharma, "A Low-Power and Compact Analog CMOS Processing Chip for Portable ECG Recorders," Asian Solid-State Circuits Conference, 2005 , vol., no., pp.473-476, Nov. 2005.[6] Yazicioglu, R. F.; Merken, P.; Puers, R.; Van Hoof, C., "A 60 μW 60 nV/√Hz Readout Front-End for Portable Biopotential Acquisition Systems," Solid-State Circuits, IEEE Journal of , vol.42, no.5, pp.1100-1110, May 2007.[7] Chun-Lung Hsu; Mean-Hom Ho; Yu-Kuan Wu; Ting-Hsuan Chen, "Design of Low-Frequency Low-Pass Filters for Biomedical Applications," Circuits and Systems, 2006. APCCAS 2006. IEEE Asia Pacific Conference on , vol., no., pp.690-695, 4-7 Dec. 2006.[8] Chun-Chieh Huang,; Shao-Hang Hung,; Jen-Feng Chung,; Lan-Da Van,; Chin-Teng Lin,, "Front-end amplifier of low-noise and tunable BW/gain for portable biomedical signal acquisition," Circuits and Systems, 2008. ISCAS 2008. IEEE International Symposium on , vol., no., pp.2717-2720, 18-21 May 2008.[9] M. Falkenstein, J. Hohnsbein, J. Hoormann, and L. Blanke,” Effects of crossmodal divided attention on late ERP components. II. Error processing in choice reaction tasks,” Electroencephalography and Clinical Neurophysiology, vol. 78, pp. 447-55, 1991.[10] S. Makeig, M. Westerfield, T.P. Jung, S. Enghoff, J. Townsend, E. Courchesne, and T. J. Sejnowski,” Electroencephalographic Sources of Visual Evoked Responses,“ Science, vol. 295, pp. 690-694, Jan. 25,2002.[11] N. G. Einspruch, “VLSI Handbook – Handbook in Science and Technology,” Academic Press, 1986.[12] N. G. Einspruch and R. D. Gold, “VLSI in Medicine – VLSI Electronics Microstructure Science,” Academic Press, 1989.[13] Chih-Jen Yen; Wen-Yaw Chung; Mely Chen Chi; Shing-Hao Lee, "A 0.75-mW analog processor IC for wireless biosignal monitor," Low Power Electronics and Design, 2003. ISLPED '03. Proceedings of the 2003 International Symposium on , vol., no., pp. 443-448, 25-27 Aug. 2003.[14] Qiuting Huang; Oberle, M., "A 0.5-mW passive telemetry IC for biomedical applications," Solid-State Circuits, IEEE Journal of , vol.33, no.7, pp.937-946, Jul 1998.[15] Wen-Yaw Chung; Kang-Ping Lin; Chih-Jen Yen; Cheng-Lun Tsai; Te-Shin Chen, "Analog processor chip design for the bio-signal readout circuit application," [Engineering in Medicine and Biology, 1999. 21st Annual Conf. and the 1999 Annual Fall Meeting of the Biomedical Engineering Soc.] BMES/EMBS Conference, 1999. Proceedings of the First Joint , vol.2, no., pp.881 vol.2-, Oct 1999.[16] Refet Firat Yazicioglu; Patrick Merken; Robert Puers; Chris Van Hoof, "Low-Power Low-Noise 8-Channel EEG Front-End ASIC for Ambulatory Acquisition Systems," Solid-State Circuits Conference, 2006. ESSCIRC 2006. Proceedings of the 32nd European , vol., no., pp.247-250, Sept. 2006.[17] Gano, A.J.; Franca, J.E., "New multiple input fully differential variable gain CMOS instrumentation amplifier," Circuits and Systems, 2000. Proceedings. ISCAS 2000 Geneva. The 2000 IEEE International Symposium on , vol.4, no., pp.449-452 vol.4, 2000.[18] Yazicioglu, R.F.; Merken, P.; Van Hoof, C., "Integrated low-power 24-channel EEG front-end," Electronics Letters , vol.41, no.8, pp. 457-458, 14 April 2005.[19] A. P. Brokaw and M. P. Timko, “An improved monolithic instrumentation amplifier,” IEEE J. Solid-State Circuits, vol. SC-10, pp. 417–423, Dec. 1975.[20] Ng, K.A.; Chan, P.K., "A CMOS analog front-end IC for portable EEG/ECG monitoring applications," Circuits and Systems I: Regular Papers, IEEE Transactions on [Circuits and Systems I: Fundamental Theory and Applications, IEEE Transactions on], vol.52, no.11, pp. 2335-2347, Nov. 2005.[21] Sackinger, E.; Guggenbuhl, W., "A versatile building block: the CMOS differential difference amplifier," Solid-State Circuits, IEEE Journal of , vol.22, no.2, pp. 287-294, Apr 1987.[22] Nicollini, G.; Guardiani, C., "A 3.3-V 800-nVrms noise, gain-programmable CMOS microphone preamplifier design using yield modeling technique," IEEE Journal of Solid-State Circuits, vol.28, no.8, pp.915-921, Aug 1993.[23] Enz, C.C.; Temes, G.C., "Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization," Proceedings of the IEEE , vol.84, no.11, pp.1584-1614, Nov 1996.[24] Steyaert, M.; Kinget, P.; Sansen, W., "Full integration of extremely large time constants in CMOS," Electronics Letters , vol.27, no.10, pp.790-791, 9 May 1991.[25] P. R. Gray; P. J. Hurst; S. H. Lewis; R. G. Meyer, “Analysis and Design of Analog Integrated Circuits,” Wiley, New York, 2000.[26] R. D. Middlebrook. Differential Amplifiers. Wiley, New York, 1963.[27] Garrett, W.; Maxfield, T., "A monolithic differential-output operational amplifier," Solid-State Circuits Conference. Digest of Technical Papers. 1972 IEEE International , vol.XV, pp. 174-175, Feb 1972.[28] Ping Wai; Chin, M.; Gray, P.; Castello, R., "A ratio independent algorithmic A/D conversion technique," Solid-State Circuits Conference. Digest of Technical Papers. 1984 IEEE International, vol.XXVII, pp. 62-63, Feb 1984.[29] R. A. Whatley. “Fully Differential Operational Amplifier with DC Common-Mode Feedback,” U.S. Patent 4,573,020, February 1986.[30] Shih, C.; Gray, P.R., "Reference refreshing cyclic analog-to-digital and digital-to-analog converters," IEEE Journal of Solid-State Circuits, vol.21, no.4, pp. 544-554, Aug 1986[31] Choi, T.C.; Kaneshiro, R.T.; Brodersen, R.W.; Gray, P.R.; Jett, W.B.; Wilcox, M., "High-frequency CMOS switched-capacitor filters for communications application," Solid-State Circuits, IEEE Journal of , vol.18, no.6, pp. 652-664, Dec 1983.[32] Ming-Jer Chen; Yen-Bin Gu; Wu, T.; Po-Chin Hsu; Tsung-Hann Liu, "Weak inversion charge injection in analog MOS switches," IEEE Journal of Solid-State Circuits, vol.30, no.5, pp.604-606, May 1995.[33] Azhari, S.J.; Fazlalipoor, H., "A novel current mode instrumentation amplifier (CMIA) topology," Instrumentation and Measurement, IEEE Transactions on , vol.49, no.6, pp.1272-1277, Dec 2000.[34] Dal Fabbro, P.A.; dos Reis Filho, C.A., "An integrated CMOS instrumentation amplifier with improved CMRR," Integrated Circuits and Systems Design, 2002. Proceedings. 15th Symposium on , vol., no., pp. 57-61, 2002.[35] A. B. Grebene, “Bipolar and MOS Analog Integrated Circuit Design,” New York: John Wiley & Sons, 1984.[36] Aldea, C.; Sabadell, J.; Celma, S.; Martinez, P.A., "Optimized design for the high-swing cascode mirror," Circuits and Systems, 1998. Proceedings. 1998 Midwest Symposium on , vol., no., pp.233-236, 9-12 Aug 1998.[37] Honglei Wu; Yong-Ping Xu, "A low-voltage low-noise CMOS instrumentation amplifier for portable medical monitoring systems," IEEE-NEWCAS Conference, 2005. The 3rd International , vol., no., pp. 295-298, 19-22 June 2005.[38] Yazicioglu, R.F.; Merken, P.; Van Hoof, C., "Effect of electrode offset on the CMRR of the current balancing instrumentation amplifiers," Research in Microelectronics and Electronics, 2005 PhD , vol.1, no., pp. 35-38 vol.1, 25-28 July 2005.[39] Patel, A.; Terry, T.; Abdel-Aty-Zohdy, H.S., "Analog multiplexing in time domain for biochemical measurement processing," Circuits and Systems, 2002. MWSCAS-2002. The 2002 45th Midwest Symposium on , vol.1, no., pp. I-60-3 vol.1, 4-7 Aug. 2002.[40] Yen, R.C.; Gray, P.R., "A MOS switched-capacitor instrumentation amplifier," Solid-State Circuits, IEEE Journal of , vol.17, no.6, pp. 1008-1013, Dec 1982.[41] Zeng, X.; Tse, C.K.; Tang, P.S., "A new scheme for complete cancellation of charge injection distortion in second generation switched-current circuits," Microelectronics and VLSI, 1995. TENCON '95., IEEE Region 10 International Conference on , vol., no., pp.127-130, 6-10 Nov 1995.[42] Calvo, B.; Sanz, M.T.; Celma, S., "Low-voltage Low-power CMOS Programmable Gain Amplifier," Devices, Circuits and Systems, Proceedings of the 6th International Caribbean Conference on , vol., no., pp.101-105, April 2006.[43] Coelho Vincence, V.; Galup-Montoro, C.; Cherem Schneider, M., "A high-swing MOS cascode bias circuit," Circuits and Systems II: Analog and Digital Signal Processing, IEEE Transactions on [see also Circuits and Systems II: Express Briefs, IEEE Transactions on] , vol.47, no.11, pp. 1325-1328, Nov 2000. | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/36946 | |
dc.language.iso |
英文 | |
dc.relation.alma |
990050634260206772 | |
dc.relation.page |
86 | |
dc.subject.keyword |
生理訊號 | |
dc.subject.keyword |
腦電圖 | |
dc.subject.keyword |
電流平衡式儀表放大器 | |
dc.subject.keyword |
切換式電容低通濾波器 | |
dc.subject.keyword |
可程式化增益放大器 | |
dc.subject.keyword |
Biomedical signal | |
dc.subject.keyword |
electroencephalogram (EEG) | |
dc.subject.keyword |
current-balancing instrumentation amplifier (CBIA) | |
dc.subject.keyword |
switched-capacitor low-pass filter (SCLPF) | |
dc.subject.keyword |
programmable gain amplifier (PGA) | |
dc.title |
可調式頻寬/增益之四通道生理訊號擷取晶片設計 | zh-TW |
dc.title |
Tunable BW/Gain Circuit Design of Four-Channel Bio-Signal Acquisition | en |
dc.type |
Thesis | zh-TW |
檔案
- 263601.pdf (7.61 MB, Adobe PDF)
所屬典藏: 電控工程研究所