摘要

口腔植體作為現今治療缺牙患者的主要方法之一,其設計對於骨骼健康狀況與骨整合具有重大影響。本研究主要分為兩個部份,第一部份為利用有限元素模擬分析多孔植體的生物力學行為,第二部份為利用拓樸最佳化設計新式口腔植體。鈦合金由於其卓越的材料特性,廣泛應用於口腔植體的製作。然而,鈦合金的高彈性模數引致應力大部份由植體承受,這成為植牙手術的主要失敗原因之一。近年來,隨著3D列印技術的進步,多孔結構植體成為改善骨骼質植體界面應力分佈的新方向。本研究透過有限元素模擬評估不同多孔植體設計對於骨骼應力的影響,並以骨骼元素的應變值作為評估骨健康狀況的標準。
研究結果顯示多孔結構有助於術後骨骼生長,尤其是當多孔結構位於植體上半部時,其健康骨比率提高了10%。然而,其幾何結構會引起植體嚴重應力集中,可能導致植體損壞。同時本研究透過力學測試驗證有限元素模型的可靠性。對於骨骼狀況極差的缺牙患者,傳統植體適用性有限,可能導致植入失敗。為此,本研究提出一種新式口腔植體,結合柱狀短植體與多孔板狀植體,通過螺絲與齒槽骨固定。然而,大體積的金屬板可能引起不適感並增加癒合難度。因此,本研究運用拓樸最佳化技術,對新式口腔植體的幾何形狀進行優化,在特定條件下減少植體的體積,並進一步降低骨骼應力。結果顯示,拓樸最佳化設計成功降低30.41%的植體體積,並使骨骼應力最大值降低77.26%,展現優異的生物力學表現。
Dental implants are currently one of the primary methods for treating edentulous patients, and the designs of implants have a great influence on bone health and osseointegration. This study is divided into two parts: (1) the biomechanical analysis of porous implants using the finite element method, and (2) the design of novel dental implants via topology optimization. Titanium alloy is widely used for dental implant fabrication, due to its excellent material properties. However, the high elastic modulus of titanium alloys leads to uneven stress distribution in bone, which is a significant contributing factor to implant failure. In recent years, porous implants have emerged as a novel approach to ameliorate stress distribution at the bone-implant interface with the advancement of 3D printing technology.

The present study employed finite element simulation to evaluate the influence of various porous implant designs on bone stress distribution. Strain value of the bone elements was used as an indicator for evaluating bone health. The results revealed that porous structures promote postoperative bone growth. particularly when the porous structure is located in the upper region of the implant. This configuration leads to a 10% increase in the proportion of healthy bone. The reliability of the finite element model was successfully validated via mechanical testing. For edentulous patients with poor bone quality, the suitability of traditional implants is limited, leading to potential implantation failure. Thus, a novel dental implant design was proposed in this research, combining a short cylindrical implant and a porous plate implant, which were screwed to the alveolar bone. However, a large metal plate may cause discomfort and increase the difficulty of postoperative healing. Therefore, in this study, topology optimization was used to optimize the geometry of a novel dental implant to reduce the implant volume and further reduce bone stress. The results indicated that the topology-optimized design successfully reduced the implant volume by 30.41% and reduced the maximum bone stress by 77.26%, demonstrating excellent biomechanical performance.
顯示完整詮釋資料 統計資料

引用此條目

李梓峰 (2023). 利用有限元素法進行多孔植體設計與生物力學分析. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/374