即時獨立成分分析演算法應用於無線嵌入式腦機介面
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
林進燈 | |
dc.contributor.author |
蔡依伶 | |
dc.contributor.author |
||
dc.contributor.college |
電機學院 | |
dc.contributor.committee |
||
dc.contributor.committee |
||
dc.contributor.department |
電控工程研究所 | |
dc.contributor.studentid |
9512541 | |
dc.date.NCLavailable |
2010/08/21 | |
dc.date.USTavailable |
2010/08/21 | |
dc.date.issued |
2008 | |
dc.date.issuedROC |
97 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
96 | |
dc.description.abstract |
為了增進腦機介面(Brain-Computer Interface, BCI)使其可適用於真實的生活環境,線上(online)人為校正、特徵擷取、圖像事別等訊號處理技術是不可或缺的。因此腦機介面系統必須是個便利的大小、堅固耐用、重量輕且低功率消耗來達到可穿戴、可攜性與持久性的需求。本論文提出一個視窗移動(Moving-Window)的獨立成分分析法(Independent Component Analysis)並應用於一個以電池供應電源、微小化的嵌入式腦機介面。本論文也藉由模擬訊號與真實腦波訊號測試此嵌入式腦機介面。且經由實驗結果指出視窗移動的獨立成分演算法的分離效果與同樣離線(offline)演算法,提出獨立成分分析演算法在腦機介面上即時分析的可行性。為了展示可穿戴式嵌入式腦機介面的可行性,本論文也實現了移動與平均(Moving-average)頻譜分析於獨分成分分析結果的成分作用來達到即時並連續偵測受測者的任務表現。 | |
dc.description.abstract |
Online artifact correction, feature extraction, and pattern recognition are essential to advance the brain computer interface (BCI) technology so as to be practical for real-world applications. The BCI system should also be a convenient size, rugged, lightweight, and have low power consumption to meet the requirements of wearability, portability, and durability. This thesis proposes and implements a moving-windowed Independent Component Analysis (ICA) on a battery-powered, miniature, embedded BCI. This thesis also tests the embedded BCI on simulated and real EEG signals. Experimental results indicated that the efficacy of the window-based ICA decomposition is comparable with that of the offline version of the same algorithm, suggesting the feasibility of ICA for real-time analysis of EEG in a BCI. To demonstrate the feasibility of the wearable embedded BCI, this thesis also implements a moving-average spectral analysis to the resultant component activations to continuously estimate subject’s task performance in near real time. | |
dc.description.abstractopendate |
||
dc.description.degree |
碩士 | |
dc.description.tableofcontents |
Chapter 1 Introduction 11.1 Brain Computer Interface 11.2 Previous Work 11.3 Motivation 41.4 Organization of Thesis 4Chapter 2 Material and Method 62.1 Introduction 62.2 Material 62.2.1 Electroencephalogram 62.2.2 EEG signal acquisition 72.3 Methods of Data Analysis 92.3.1 Independent Component Analysis 92.3.2 Power Spectrum Analysis 15Chapter 3 Hardware Frameworks of Portable Data Acquisition 173.1 Introduction 173.2 Portable Data Acquisition System 173.2.1 Four-Channel Front-End Circuits 183.2.2 Analog to Digital Converter 223.2.3 Digital Controller 233.3 Wireless Transmission 243.4 Data Processing Platform 25Chapter 4 Real-Time ICA Signal Processing 284.1 Introduction 284.2 EEG Data for ICA 284.3 Information Maximization ICA 314.4 Real-Time Signal Processing 344.4.1 Window-Based ICA 344.4.2 Verification of Window-Based ICA 354.4.3 Real-Time ICA 414.4.4 Verification of Real-Time ICA 43Chapter 5 Experiment Results 515.1 Introduction 515.2 ICA Verification on EEG Signal 515.2.1 Description of EEG Data 515.2.2 Signal Processing Procedure on Drowsy Estimation 545.3 Verification of Real EEG Signals 555.3.1 Down Sampling 555.3.2 Moving-Average Spectrum Analysis 585.3.3 Real EEG Signal Result 60Chapter 6 Conclusions 64References 66 | |
dc.identifier.citation |
[1] S.G. Mason, A. Bashashati, M. Fatourechi, K.F. Navarro, and G.E. Birch, “Acomprehensive survey of brain interface technology designs,’’ Ann. Biomed. Eng.,vol. 35, no. 2, pp. 137–169, 2007.[2] A. Kachenoura, L. Albera, L. Senhadji, and P. Comon, “ICA: A Potential Tool for BCI Systems,” IEEE Signal Processing Magazine, pp. 57-68, Jan 2008.[3] J. Kalcher, D. Flotzinger, C. Neuper, S. Gölly, and G. Pfurtscheller, “Graz brain–computer interface II: Toward communication between humans and computers based on online classification of three different EEG patterns,” Med. Biol. Eng. Comput., vol. 34, pp. 382–388, 1996.[4] C. Guger, W. Harkam , C. Hertnaes, G. Pfurtscheller, “Prosthetic Control by an EEG-based Brain-Computer Interface (BCI)”, Proceedings of AAATE 5th European Conference for the Advancement of Assistive Technology. Düsseldorf, Germany, November 3-6, 1999.[5] M. Falkenstein, J. Hohnsbein, J. Hoormann, and L. Blanke, “Effects of crossmodal divided attention on late ERP components. II. Error processing in choice reaction tasks,” Electroencephalography and Clinical Neurophysiology, vol. 78, pp. 447-55, 1991.[6] S. Makeig, M. Westerfield, T.P. Jung, S. Enghoff, J. Townsend, E. Courchesne, and T. J. Sejnowski, “Electroencephalographic Sources of Visual Evoked Responses,” Science, vol. 295, pp. 690-94, Jan. 25,2002.[7] M.D. Serruya, N.G. Hatsopoulos, L. Paninski, M.R. Fellows, J.P. Donoghue, “Instant neural control of a movement signal,” Nature, vol. 416,pp. 141–142, 2002.[8] D.M. Taylor, S.I. Tillery, A.B. Schwartz, “Direct cortical control of 3D neuroprosthetic devices,” Science, vol. 296, pp. 1829–1832, 2002.[9] J.K. Chapin, K.A. Moxon, R.S. Markowitz, M.A.L. Nicolelis, “Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex,” Nature Neuroscience, vol. 2, pp. 664–670, 1999.[10] J. Wessberg, C.R. Stambaugh, J.D. Kralik, P.D. Beck, M. Laubach, “Realtime prediction of hand trajectory by ensembles of cortical neurons in primates,” Nature, vol. 408, pp. 361–365, 2000.[11] 連怡仲,“數位腦波機系統之設計與研製”,國立台灣大學,碩士論文,民國八十六年。[12] 杜益昌,“多通道腦波機系統之設計與裝置”,國立台灣大學,碩士論文,民國八十七年。[13] 林伯星,“數位腦波機系統之人機介面設計與研發”,國立台灣大學,碩士論文,民國八十七年。[14] 蔡進寶,“腦波紀錄儀設計與製作”,國立交通大學,碩士論文,民國八十九年。[15] 楊勝文,“可攜式智慧型腦波記錄器”,國立台灣大學,碩士論文,民國九十年。[16] 黃名斌,“USB 介面之模組化腦波記錄儀”,國立中原大學,碩士論文,民國九十一年。[17] 吳炎法,“研製無線化多通道腦波系統並運NAB 方法進行腦波分類之研究”,國立台北科技大學,碩士論文,民國九十二年。[18] M. Cheng, X. Gao, S.K. Gao, and D.F. Xu, “Design and Implementation of a Brain-Computer Interface With High Transfer Rates,” IEEE Transaction biomedical Engineering, vol. 49, pp. 1181-1186, 2002.[19] X.R, Gao, D.F. Xu, M. Cheng, and S.K. Gao, “A BCI-Based Environmental Controller for the Motion-Disabled,” IEEE Transaction Neural Systems and Rehabilitation Engineering, vol. 11, pp. 137-140, June 2003.[20] B. Obermaier, “Design and implementation of an EEG based virtual keyboard using hidden Markov models”, Ph.D. dissertation, Technical University-Graz, Graz, Austria, 2001.[21] B. Obermaier, C. Neuper, and G. Pfurtscheller, “Information transfer rate in a 5 classes brain-computer interface,” IEEE Transaction Rehabilitation Engineering, vol. 9, pp. 283-288, 2001.[22] G. Edlinger, G. Krausz, F. Laundl, I. Niedermayer, C. Guger, “Architectures of Laboratory-PC and Mobile Pocket PC Brain-Computer Interfaces,” in Proceedings of the 2 International IEEE EMBS Conference on Neural Engineering, Arlington, Virginia, March 16 - 19, 2005.[23] K. Ashwin Whitchurch, B. Han Ashok, R. Vinod Kumaar and K. Sarukesi, and K. Vijay Varadan, “Wireless system for long term EEG monitoring of Absence Epilepsy,” Biomedical Applications of Micro- and Nanoengineering, Proceedings of SPIE, Vol. 4937, pp. 343-349, November 2002.[24] P. Comon, “Independent component analysis, a new concept?’’ Signal Process., vol. 36, no. 3, pp. 287–314, Apr. 1994[25] T. P. Jung, S. Makeig, T. W. Lee, M. J. Mckeown, G. Brown, A. J. Bell, and T. J. Dejnowski, “Independent Component Analysis of Biomedical Signals,” in Proceedings of the 2nd International Workshop on Independent Component Analysis and Blind Signal Separation, pp. 633-44, 2000[26] R. Vigário, J. Särelä, V. Jousmäki, M. Hämäläinen, and E. Oja, “Independent Component Approach to the Analysis of EEG and MEG Recordings,” IEEE Transactions on Biomedical Engineering, vol. 47, no. 5, pp. 589-593, May 2000[27] T. P. Jung, C. Humphries, T. W. Lee, S. Makeig, M. J. McKeown, V. Iragui, and T. J. Sejnowski, “Extended ICA removes artifacts from electroencephalographic recordings,” Advances in Neural Information Process. Syst., vol. 10, pp. 894–900, 1998.[28] N.J. Hill, T.N. Lal, K. Bierig, N. Birbaumer, and B. Scholkopf, “ Attentional modulation of auditory event-related potentials in a brain-computer interface,’’ in Proc. IEEE Int. Workshop Biomedical Circuits and Systems, Singapore, 2004, pp.17–20.[29] B. Kamousi, Z. Liu, and B. He, “Classification of Motor Imagery Tasks for Brain-Computer Interface Applications by Means of Two Equivalent Dipoles Analysis,” IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 13, No. 2, pp. 166-171June 2005.[30] C. J. James and S. Wang, “Blind source separation in single-channel EEG analysis: An application to BCI,” in Proc. 28th Annu. Int.Conf. IEEE Engineering in Medicine and Biology Society, New York, USA, pp. 6544-6547, Aug. 2006.[31] UW Computing & CommunicationsURL: http://faculty.washington.edu/chudler/1020.html[32] A. Papoulis, “Minimum bias windows for high resolution spectral estimation,” IEEE Trans. Info. Theory, vol. IT-19, pp. 9–12, 1973.[33] M. Steriade, “Central core modulation of spontaneous oscillations and sensory transmission in thalamocortical systems,” Current Opin. Neurobiol., vol. 3, no. 4, pp. 619–625, 1993.[34] A. Destexhe, D. Contreras, and M. Steriade, “Spatiotemporal analysis of local field potentials and unit discharges in cat cerebral cortex duringnatural wake and sleep states,” J. Neurosci., vol. 19, pp. 4595–4608,1999.[35] C. T. Lin, R. C.Wu, T. P. Jung, S. F. Liang, and T. Y. Huang, “Estimating driving performance based on EEG spectrum analysis,” EURASIP J. Applied Signal Process., Vol. 2005, No. 19, pp. 3161-3174, Mar. 2005.[36] Altera Inc. ,URL: http://www.altera.com/[37] CSR Inc. ,URL: http://www.csrsupport.com/BC4Ext[38] Analog Devices Inc. ,URL: http://www.analog.com/[39] B. Ans, J. Herautl, and C. Jutten, “Adaptative neural architectures: Detection of primitives,’’ in COGNITIVA’85, Paris, France, June 1985, pp. 593–597.[40] A. J. Bell and T. J. Sejnowski, “An Information-Maximization Approach to Blind Separation and Blind Deconvolution,” Neural computation, pp. 1129-1159,1995[41] M. Falkenstein, J. Hohnsbein, J. Hoormann, and L. Blanke, “Effects of crossmodal divided attention on late ERP components. II. Error processing in choice reaction tasks,” Electroencephalography and Clinical Neurophysiology, vol. 78, pp. 447-55, 1991.[42] S. Makeig, M. Westerfield, T.P. Jung, S. Enghoff, J. Townsend, E. Courchesne, and T. J. Sejnowski, “Electroencephalographic Sources of Visual Evoked Responses,” Science, vol. 295, pp. 690-94, Jan. 25,2002.[43] C. T. Lin, R. C. Wu, S. F. Liang, W. H. Chao, Y. J. Chen, and T. P. Jung, “EEG-based drowsiness estimation for safety driving using independent component analysis,” IEEE Trans on Circuits and Systems I, vol. 52, no. 12, pp. 2726-2738, 2005.[44] T. W. Lee, M. Girolami, and T. J. Sejnowski, “Independent component analysis using an extended infomax algorithm for mixed sub-Gaussian and super-Gaussian sources,” Neural Computation, vol. 11, pp. 606-633, 1999.[45] S. Makeig, T.P. Jung, and T.J. Sejnowski, “Awareness during drowsiness: dynamics and electrophysiological correlates,” Canadian Journal of Experimental Psychology, vol. 54, pp.266-273, 2000[46] S. Makeig and T.P. Jung, “Tonic, phasic, and transient EEG correlates of auditory awareness in drowsiness,” Cognitive Brain Research, vol. 4, pp. 15-25, 1996.[47] M. A, Schier, “Changes in EEG alpha power during simulated driving: a demonstration,” International Journal of Psychophysiology, vol. 37, pp.155-162, 2000.[48] W. Wang and C. James, “Enhancing evoked responses for BCI through advanced ICA techniques,’’ in Proc. 3rd International Conf. Advances in Medical, Signal, and Information Processing, Glasgow, UK, pp. 38-41, July 2006.[49] S. L. Joutsiniemi, S. Kaski, and T.AndreoLarsen, “Self-organizing map in recignition of topographic patterns of EEG spectra,” IEEE Transactions on Biomedical Engineering, vol. 42, no. 11, 1995.[50] I. Obeid, M. A.L. Nicolelis, and P. D. Wolf, “A multichannel telemetry system for single unit neural recordings,” Journal of Neuroscience Methods, vol. 133, issues 1-2, pp. 33-38, Feb 2004.[51] I. Obeid, M. A.L. Nicolelis, and P. D. Wolf, “ A low power multichannel analog front end for portable neural signal recordings.” Journal of Neuroscience Methods, vol. 133, issues 1-2, pp. 27-32, Feb 2004.[52] 黃冠智,”即時DSP嵌入式Linux系統開發及其於腦波訊號處理之應用” ,國立交通大學,碩士論文,民國九十三年。[53] 謝弘義,”即時DSP嵌入式Linux系統開發及其於腦波訊號處理之應用” ,國立交通大學,碩士論文,民國九十四年。 | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/37549 | |
dc.language.iso |
英文 | |
dc.relation.alma |
991003691711706772 | |
dc.relation.page |
72 | |
dc.subject.keyword |
腦機介面 | |
dc.subject.keyword |
獨立成分分析 | |
dc.subject.keyword |
腦波 | |
dc.subject.keyword |
Brain Computer Interface | |
dc.subject.keyword |
ICA | |
dc.subject.keyword |
EEG | |
dc.title |
即時獨立成分分析演算法應用於無線嵌入式腦機介面 | zh-TW |
dc.title |
Real-Time ICA Applied on Wireless EEG-Based Brain-Computer Interface | en |
dc.type |
Thesis | zh-TW |
檔案
- 254101.pdf (4.23 MB, Adobe PDF)
所屬典藏: 電控工程研究所