風機塔柱螺栓接頭的健康診斷
Health Diagnosis of Bolted Joints for Wind Turbine Towers
摘要
本研究主要為風力發電機塔架底部法蘭的螺栓接頭做健康檢測分析。塔架因風力造成 螺栓的失效 在作動時塔架會振動並直接影響所發出電信號的穩定性。為了檢測風電機塔架基礎結構的穩定性針對其進行了穩態的振動分析,在 ANSYS有限元素模型中,使用實體元素 SOLID185針對不同失效螺栓狀況進行自然頻率及模態分析,接著根據實際風機塔架的結構特點 及 相關構件 來 製作模型並使用敲擊振動分析的 頻率響應 來驗證模擬分析的正確性,實驗結果發現當螺栓失效數 量的增加,自然頻率會降低,且越靠近失效螺栓的區域 敲擊 自 然頻率也會有明顯下降 。 在 判斷失效螺栓將加速計於螺栓上每隔一個間隔放置 依序 敲擊比較螺栓中間法蘭的頻率 來判別 ,也可將多個加速計置於所有的螺栓上經由敲擊所產生的不同訊號判別失效螺栓 。 為初步風機塔柱螺栓接頭的健康診斷找出合適 的方法, 讓後續的診斷提升效能 。
This study mainly performs health inspection and analysis on the bolt joints of the connecting flange at the bottom of the wind turbine tower. The bolts of the tower fail due to wind force, and the tower will vibrate during operation and directly affect the stability of the electrical signal sent. In order to detect the stability of the wind turbine tower basic structure, a steady-state vibration analysis was conducted. In the ANSYS finite element model, the solid element SOLID185 was used to conduct natural frequency and modal analysis for different failed bolt conditions. Then, based on the actual wind turbine tower the structural characteristics and related components of the frame were used to make a model and the frequency response of percussion vibration analysis was used to verify the correctness of the simulation analysis. The experimental results found that when the number of bolt failures increases, the natural frequency will decrease, and the closer to the area of the failed bolt, the more the natural frequency of hits will also drop significantly. To determine the failure of a bolt, place accelerometers on the bolts at regular intervals and tap them sequentially to compare the frequencies of the flanges in the middle of the bolts. You can also place multiple accelerometers on all bolts to accelerate the different signals generated by tapping. Identify failed bolts. Find an appropriate method for preliminary health diagnosis of wind turbine tower bolt joints so that subsequent diagnosis can improve efficiency.