摘要
Photoacoustic (PA) imaging has exceptional performance in small animal tomography. In this study, we developed a custom-made photoacoustic/ultrasound (US) dual-modality imaging system to accomplish blood vessel tomography and relative oxygen saturation measurement on tumors. We also optimized the illumination angle between the laser and the transducer by analyzing the generated photoacoustic amplitude and the focusing ability between the laser source and the transducer. The optimal field of view was 13 mm to 16 mm on Z-axis. Besides, the photoacoustic resolution of the system was estimated to be 115 μm and 260 μm in the axial and the lateral by calculating the full width at half maximum (FWHM) through imaging a wire. We applied a tubing phantom as validation to verify our reliability and the reconstruction results in maximum intensity projection (MIP) images and depth images.
In animal experiments, we successfully visualized the superficial epigastric branch of mice and the corresponding sub-stream vessels. Additionally, we achieved a significant penetration depth of up to 7 mm for the excited signal. This indicates the capability of our imaging system to effectively capture and examine deeper tissue layers in small animal models. As for the tumor model, we managed to illustrate the tumor region blood vessels and the adjacency supportive vessels to further investigate the characteristics of neo-angiogenesis. With different laser wavelengths (750 nm and 850 nm), we can derive the tumor relative oxygen saturation level.
In summary, photoacoustic tomography demonstrated the feasibility of the system for tumor angiogenesis monitoring. Moreover, the system, which assists in clinical diagnosis, provides spatial information about vessels and quantifies relative oxygen saturation
In animal experiments, we successfully visualized the superficial epigastric branch of mice and the corresponding sub-stream vessels. Additionally, we achieved a significant penetration depth of up to 7 mm for the excited signal. This indicates the capability of our imaging system to effectively capture and examine deeper tissue layers in small animal models. As for the tumor model, we managed to illustrate the tumor region blood vessels and the adjacency supportive vessels to further investigate the characteristics of neo-angiogenesis. With different laser wavelengths (750 nm and 850 nm), we can derive the tumor relative oxygen saturation level.
In summary, photoacoustic tomography demonstrated the feasibility of the system for tumor angiogenesis monitoring. Moreover, the system, which assists in clinical diagnosis, provides spatial information about vessels and quantifies relative oxygen saturation
在先前研究中已展示光聲影像技術在小動物斷層影像上有非常良好的成像表現。在本研究中,我們開發一套客製化光聲、超音波雙模影像系統,應用於小動物血管影像重建以及腫瘤區域的相對平均血氧濃度量測。另外,我們也設計不同的雷射照射角度,探討超音波探頭與入射光雷射之間的關係,藉由分析光聲訊號以及聚焦效果以尋找最佳造影角度設計。測試結果顯示,該系統最佳的視野範圍(Z方向)在13微米到16微米之間,其橫向解析度為260微米,在軸向深度(Z方向)空間解析度為115微米。並透過仿體實驗驗證系統重建影像之最大強度投影影像與三維重建結果。
動物實驗中,該系統可以成功的造影出小鼠表淺腹部的主要分支與周邊相連之細小血管。分析斷層影像結果,該系統的成像深度可達7毫米,對於小動物深層血管造影來說非常足夠。腫瘤實驗結果呈現出腫瘤區域新生血管與周圍管脈系統,以維持腫瘤區域最佳的生長條件。另外,透過不同波長的雷射光(750奈米和850奈米),量測腫瘤區域的平均相對血氧飽和濃度為35.3%,非腫瘤區域的區域平均相對血氧飽和濃度為43.2%。
總結來說,光聲斷層掃描證明了該系統用於腫瘤新生血管監測的可行性。該系統有助於臨床診斷,提供有關腫瘤血管分布與相對血氧飽和度等重要資訊。
動物實驗中,該系統可以成功的造影出小鼠表淺腹部的主要分支與周邊相連之細小血管。分析斷層影像結果,該系統的成像深度可達7毫米,對於小動物深層血管造影來說非常足夠。腫瘤實驗結果呈現出腫瘤區域新生血管與周圍管脈系統,以維持腫瘤區域最佳的生長條件。另外,透過不同波長的雷射光(750奈米和850奈米),量測腫瘤區域的平均相對血氧飽和濃度為35.3%,非腫瘤區域的區域平均相對血氧飽和濃度為43.2%。
總結來說,光聲斷層掃描證明了該系統用於腫瘤新生血管監測的可行性。該系統有助於臨床診斷,提供有關腫瘤血管分布與相對血氧飽和度等重要資訊。