合併髕骨列位不良之退化性膝關節炎患者下肢肌肉收縮特性研究
Muscle Activation Features of the Osteoarthritic Knee with Patellar Malalignment
摘要
臨床上發現部分內側膝關節炎患者會合併髕骨列位不良如向外傾斜或半脫位等問題,本研究目的即是比較合併與不合併髕骨外移OA患者其肌肉收縮電位與髕股骨關節型態之關係,試圖了解OA患者發生髕骨列位不良之可能成因。
本研究依X光片診斷,將受試者分成三組,A組為內側脛股骨退化性關節炎(isolate medial TF OA),B組為內側退化性膝關節炎合併髕骨列位不良(OA combine patellar subluxation)。C組為沒有下肢關節及神經肌肉骨骼方面的病變或傷害的老年人。每位受試者均填寫受測者同意書及個人基本資料、Lequesne Index膝關節炎病人疼痛指數評估表,測量X光片之髕骨股骨滑車槽角度(sulcus angle)、傾斜(lateral tilting angle)及外移量(lateral displacement)等。以等速肌力測定儀設定角速度為80°/秒、120°/秒、240°/秒之等速向心收縮測得股內斜肌(VMO)與股外側肌(VL) 之EMG動作電位,計算VMO與VL 最大動作電位之比值,以皮爾森相關係數(Pearson correlation coefficient) 建立VMO與VL肌肉動作電位與骨骼結構的相關性。
結果顯示:合併髕骨外移的OA患者其VMO/VL的比值明顯比TF OA及正常人小(p<0.05),又發現其股骨滑車槽角度不僅比TF OA及正常人大,而且與VMO/VL的動作電位(r=-0.349~-0.385, p<0.05)、髕骨傾斜程度比值呈現負相關(r=-0.598, p<0.05),也就是滑車槽角度愈大,愈增加VMO與VL肌肉收縮的不平衡,而增加了髕骨傾斜程度,所以滑車槽角度的大小可能是造成OA患者發生髕骨列位不良可能成因之一。本研究之結果將可提供臨床工作者的復健治療策略之參考。
本研究依X光片診斷,將受試者分成三組,A組為內側脛股骨退化性關節炎(isolate medial TF OA),B組為內側退化性膝關節炎合併髕骨列位不良(OA combine patellar subluxation)。C組為沒有下肢關節及神經肌肉骨骼方面的病變或傷害的老年人。每位受試者均填寫受測者同意書及個人基本資料、Lequesne Index膝關節炎病人疼痛指數評估表,測量X光片之髕骨股骨滑車槽角度(sulcus angle)、傾斜(lateral tilting angle)及外移量(lateral displacement)等。以等速肌力測定儀設定角速度為80°/秒、120°/秒、240°/秒之等速向心收縮測得股內斜肌(VMO)與股外側肌(VL) 之EMG動作電位,計算VMO與VL 最大動作電位之比值,以皮爾森相關係數(Pearson correlation coefficient) 建立VMO與VL肌肉動作電位與骨骼結構的相關性。
結果顯示:合併髕骨外移的OA患者其VMO/VL的比值明顯比TF OA及正常人小(p<0.05),又發現其股骨滑車槽角度不僅比TF OA及正常人大,而且與VMO/VL的動作電位(r=-0.349~-0.385, p<0.05)、髕骨傾斜程度比值呈現負相關(r=-0.598, p<0.05),也就是滑車槽角度愈大,愈增加VMO與VL肌肉收縮的不平衡,而增加了髕骨傾斜程度,所以滑車槽角度的大小可能是造成OA患者發生髕骨列位不良可能成因之一。本研究之結果將可提供臨床工作者的復健治療策略之參考。
Objective: Clinically, patients with osteoarthritic (OA) knee often have quadriceps weakness. We have noticed that some OA knee patients also combine this with patellar malalignment. The aim of this study was to compare the difference of muscle activation pattern and patellofemoral joint (PFJ) morphology between OA knee patients with and without patellar malalignment.
Subjects: For statistical comparisons, three groups of subjects were studied. Group A comprised of subjects with the bilateral OA knee. Group B comprised subjects with the bilateral OA knee, and also with patellar malalignment on at least one side. Group C comprised of age-matched normal subjects.
Methods: The three groups were compared by using an isokinetic dynamometer with surface electromyography (EMG) recording to measure the maximal muscle activity in terms of the vastus medialis oblique/vastus lateralis ratio (VMO/VL) and by Merchant’s view radiography for the analysis of the bony anatomy of the patellofemoral joint. The recordings were done with three angular velocities which were 80, 120 and 240 º/s.
Results: There was no significant difference in knee extension strengths between groups A and B. However, both groups A and B (knee OA patients with and without patellar malalignment) showed significantly weaker (p<0.05) strength than group C (normal controls). A more noticeable finding involved the VMO/VL EMG activity ratio. There was no difference in the VMO/VL ratio between group A and group C, as they both were close to 1.0. However, a significant difference (p<0.05) was found between group A and B, with group B showing a significant reduction in the VMO/VL ratio.
The morphological findings of the PFJ in subjects of group B had a larger sulcus angle, lateral patellar tilting and lateral patellar displacement when compared to group A and healthy subjects. All of the EMG ratios were negatively correlated with sulcus angle at 80, 120 and 240 º/s (r= - 0.349 ~ - 0.385, p<0.05).
Conclusion: OA knee with patellar malalignment patients had associated with not only quadriceps weakness but also musculature imbalance in VMO and VL muscle. In addition, OA knee subjects with patellar malalignment had larger sulcus angle of the patellofemoral joint. Morphology of the sulcus angle of patellofemoral joint was negatively correlated with the VMO/VL EMG ratio and patellar tilting. It may be an important factor causing imbalance in muscle activities of VMO and VL during quadriceps contraction.
Subjects: For statistical comparisons, three groups of subjects were studied. Group A comprised of subjects with the bilateral OA knee. Group B comprised subjects with the bilateral OA knee, and also with patellar malalignment on at least one side. Group C comprised of age-matched normal subjects.
Methods: The three groups were compared by using an isokinetic dynamometer with surface electromyography (EMG) recording to measure the maximal muscle activity in terms of the vastus medialis oblique/vastus lateralis ratio (VMO/VL) and by Merchant’s view radiography for the analysis of the bony anatomy of the patellofemoral joint. The recordings were done with three angular velocities which were 80, 120 and 240 º/s.
Results: There was no significant difference in knee extension strengths between groups A and B. However, both groups A and B (knee OA patients with and without patellar malalignment) showed significantly weaker (p<0.05) strength than group C (normal controls). A more noticeable finding involved the VMO/VL EMG activity ratio. There was no difference in the VMO/VL ratio between group A and group C, as they both were close to 1.0. However, a significant difference (p<0.05) was found between group A and B, with group B showing a significant reduction in the VMO/VL ratio.
The morphological findings of the PFJ in subjects of group B had a larger sulcus angle, lateral patellar tilting and lateral patellar displacement when compared to group A and healthy subjects. All of the EMG ratios were negatively correlated with sulcus angle at 80, 120 and 240 º/s (r= - 0.349 ~ - 0.385, p<0.05).
Conclusion: OA knee with patellar malalignment patients had associated with not only quadriceps weakness but also musculature imbalance in VMO and VL muscle. In addition, OA knee subjects with patellar malalignment had larger sulcus angle of the patellofemoral joint. Morphology of the sulcus angle of patellofemoral joint was negatively correlated with the VMO/VL EMG ratio and patellar tilting. It may be an important factor causing imbalance in muscle activities of VMO and VL during quadriceps contraction.