微型電腦斷層效能評估及骨質密度校正假體之發展

Developments of phantoms for performance evaluation of micro-CT and calibration of bone mineral density

檔案

日期

2008

類型

語言

中文

摘要

微型電腦斷層儀有許多特點,例如:極高的影像空間解析度、良好的影像對比、低影像雜訊、直接獲得體積資訊、非侵入式檢查、專為小樣品、小動物設計等特性。因此在近幾年來,微型電腦斷層儀深受研究及產業界的重用,不管是從檢查基因轉殖或剔除的小鼠結構上之變化、生醫材料在樣品上之效用、到工業上電子零件的製造品管及非破壞性檢測,都可以看到微型電腦斷層儀帶來的助益。而如此強力的儀器就如同其他儀器,也需要有可以作規律品質保證的工具。國外許多研究學者針對這個問題,從臨床到微型電腦斷層儀都有許多研究與發表。在本次研究中,我們發展兩套品質保證及效能假體和一套影像分析的程式。藉由將此效能假體於微型電腦斷層儀作影像擷取及重組之後,利用影像分析程式對重組後的斷層影像進行效能分析之後即可提供具參考價值的效能定性及定量參數,包括了空間解析度、雜訊、線性度、骨質密度校正、與硬體校準的評估。此研究中所發展的效能假體考慮到較低製作上的成本、使用方便性的提升、使用材料的合理性、與配合微型電腦斷層儀的特性。除此之外,此效能假體與分析程式更可以應用在其他臨床前研究的造影工具,包括正子斷層掃描儀等,提供更廣的應用價值。
Micro-computed tomography (micro-CT) has many features, such as: high spatial resolution, good image contrast, and low image noise, direct access to the volume information, non-destructive inspection, and specific for the small samples and small animals. Therefore, in recent years, micro-CT plays an important role in preclinical research and industry; whether the inspection of structural changes for transgenic or knock-out mice, the effectiveness of biomaterials on of the sample, industrial electronic components manufacturing quality control and non-destructive testing, all can see micro-CT’s contribution. Such powerful apparatus, like other instruments, needs good quality assurance (QA) tools. Many scholars have addressed this issue, from the clinical to micro-CT, and have numerous published papers. In this study, two sets of quality assurance and performance evaluation phantom and one analysis program were developed. With this performance phantom for micro-CT image acquisition followed by reconstruction, the CT imaging performance evaluation can be conducted to provide a reference value for the performance of qualitative and quantitative parameters, including spatial resolution, noise, linearity, bone mineral density calibration, and hardware alignment. The development of the phantom take into account the lower production cost, easy-to-use and the reasonable use of materials, and micro-CT instrument characteristics. In addition, the performance phantom and analysis programs can be used in other pre-clinical research imaging tools, including positron emission tomography, micro-magnetic resonance imaging, and so on, to provide broader applications.
顯示完整詮釋資料 統計資料

引用此條目

蔡文凱 (2008). 微型電腦斷層效能評估及骨質密度校正假體之發展. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/39274

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/39274