人工椎間盤外型改變對聚乙烯受力情形的影響

The Effects of Changing Artificial Disc Shape on PE Loading Distribution

檔案

全文未公開。

日期

2008

類型

語言

中文

摘要

外科治療下背痛主要有融合術和椎間盤置換兩種。雖然脊椎融合術能直接達到減壓的目的,但也增加了鄰近椎節提早退化的風險。之前人工椎間盤的研究,大多進行椎間融合器和人工椎間盤有限元模擬的生物力學相互比較,但目前仍沒有針對人工椎間盤曲面變化的分析研究。本研究利用CT影像建出L4-L5的三維模型,並用CAD軟體分別建立PE為凸面、凹面、橢圓的人工椎間盤,分別模擬(1)三種形狀PE位置在下方 (2)PE為凹面和凸面且分別置放在上方和下方兩種位置時腰椎屈曲/伸展、側彎和軸向旋轉下,PE所受到剪應力和von Mises應力及其分佈。結果顯示三種設計在屈曲下都有最大的剪應力發生,曲面為凸的剪應力最高,為23.81MPa。曲面為凹的設計在任何情況下都比曲面為凸的應力來得小。橢圓能夠有效抵抗過多的旋轉,但受到61.36MPa的von Mises應力為三者最高,僅次於在屈曲動作下。PE為凸面置放在上方結果顯示PE在上方除了在旋轉時剪應力較小,其他動作下不管是剪應力和von Mises應力都來得大,但差異性不大。PE為凹面置放在上方結果顯示都比置放在下方應力來得大。曲面為凸之剪應力超過降伏應力,有可能發生橫切面的破壞。曲面為凹面有效降低應力集中問題且受力較小,結果顯示曲面為凹面的設計具可行性。橢圓則需要進一步探討長短軸與運動模式之間的關係。
Spinal interbody fusion and disc replacement are the main surgical treatments for low back pain resulted from intervertebral disc degeneration. Spinal interbody fusion is an effective way to achieve the purpose of nerve root decompression, but it also increases risk of accelerating adjacent disc degeneration. Previous coMParative studies about cages and artificial discs in biomechanical performances were mostly done with finite element analyses, but still it has never been analyzed with changing artificial disc curve. Three-dimensional finite element model of human L4-L5 was reconstructed with CT images in this study, and convex, concave and ellipse artificial disc models were also established referring to commercially available products with CAD software. Simulations included:(1) three types of PE were implanted inferiorly (2) concave and convex PE components implanted on superior or inferior sides of lumbar spine in flexion/extension, lateral bending and axial rotation in lumbar spine. Shear stresses and von Mises stresses on PE were evaluated for their loading distributions. The results showed high shear stresses of all types occurred in flexion, and convex PE was 23.81 MPa at best. In all conditions, stresses distributed more evenly and lower than those on the convex sides. The elliptic geometry enabled to confine the rotation of the motion unit. The elliptic geometry enabled to confine the rotation angle. However, the von Mises stress in rotation was 61.36 MPa on ellipse which was larger than other motions excepted flexion. Convex PE placed on superior side resulted in larger shear stress and von Mises stress than on inferior side, excepted for shear stress in rotation, but no significant difference was found. Concave PE placed on superior side resulted in large stress than on inferior side. The shear force on convex design could induce transverse crack because the shear stress exceeded yielding shear stress. The concave design not only decreased loading concentration but had relatively low stress. Such a design may be applicable in the future. Further study will aim at the design about two principal axes of the ellipse shape and its motion patterns.
顯示完整詮釋資料 統計資料

引用此條目

陳裕文 (2008). 人工椎間盤外型改變對聚乙烯受力情形的影響. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/39277

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/39277