根據世界衛生組織2003年的報告顯示,全世界每年有500萬人因吸菸而死亡,吸菸除了導致吸菸者本身之健康危害,也會使週遭的非吸菸者面臨二手菸暴露(Environmental tobacco smoke)的危險。近年來世界衛生組織推動「健康工作環境」,其中即包括職場二手菸防制。國內大型工作職場在菸害防制上多以設置「吸菸室」因應,其效果如何相關研究並不多見,有鑒於此,本研究以北部某高科技廠為例,針對其吸菸室內外空氣中尼古丁濃度做一探討,同時收集該職場內員工尿液,測定其尿中尼古丁與可丁寧濃度作為暴露的生物指標,以評估該限菸職場之二手菸防制效果。
本研究總計採集159人之「上班前」及「下班時」尿液,共318個樣本。尼古丁與可丁寧濃度以GC-MS氣相層析質譜儀定量之。
本研究發現,吸菸室內尼古丁空氣濃度平均值為28.1 μg/m3,最高測值達133.7 μg/m3。吸菸室外及其他辦公場所均未偵測出尼古丁。細微粒部分,吸菸室內空氣PM2.5濃度平均值達697.8 μg/m3,最高測值高達2440.0 μg/m3,吸菸室外各場所的細微粒濃度平均值為25 μg/m3~30 μg/m3。顯示該公司吸菸室隔菸效果良好。
廠內員工尿中尼古丁(nicotine)及其代謝物可丁寧(cotinine)測定結果發現,吸菸者的尼古丁與可丁寧濃度在上班前的濃度均高於下班時濃度。尿中尼古丁與可丁寧濃度與吸菸量呈正比,重度吸菸(每天>1包)者濃度>中度吸菸(每天<1包)者>輕度吸菸(偶爾吸菸)者。
非吸菸員工在下班時仍有尼古丁與可丁寧濃度測出,且非吸菸者的尼古丁與可丁寧濃度在上班前的濃度均低於下班時濃度,顯示工作場所受到的二手菸暴露比起下班後受到的暴露為高。
因此在限菸的工作場所中,若其吸菸室設有獨立的空調設備及完善的隔絕措施,將可避免菸塵的擴散,但若要有效預防職場內員工避免二手菸的危害,吸菸室對於員工的可近性以及平常對於廠內吸菸員工的教育訓練與宣導都需納入考慮。
Cigarette smoking is known to be the cause of several adverse health effects to both active smokers and non-smokers exposed to environmental tobacco smoke (ETS). According to the world health report 2003, about 5 million people die as a result of smoking. ETS exposure is also associated with an increased risk of several respiratory illness and heart disease.
The WHO has tried to carry out healthy work environment in recent years, and how to minimize or eliminating the ETS exposure in the workplace is one of the target task. However, the designated smoking and non-smoking areas could provide how much protection from ETS exposure in the workplace has not yet been concerned in Taiwan.
In this study, we investigated one hi-tech workplace in the north with restricted-smoking policy to compare the airborne nicotine levels and indoor air quality between the smoking room and non-smoking areas. Further, pre- and post-shift urinary nicotine and cotinine levels were determined in identical subjects staying in the restricted smoking environment for 8 hours. The purpose of this study was to assess the effectiveness of smoking control programs in the hi-tech workplace.
In total, 159 subjects provided their urine samples for nicotine and cotinine measurements. Nicotine and cotinine levels were measured by GC-MS.
The results showed the mean levels of airborne nicotine and PM2.5 were much higher in the smoking room compared to non-smoking areas. For nicotine, mean levels were 28.1 μg/m3 in the smoking room and non-detectable in the non-smoking areas. Corresponding PM2.5 levels were 697.8 μg/m3 and 30 μg/m3. This suggest the isolation of smoking room could provide protection from environmental tobacco smoke.
In addition, the geometric mean urinary nicotine and cotinine concentration differed between smokers and non-smokers. For smokers, the nicotine and cotinine levels declined after staying in the restricted smoking environment for 8 hours. The mean values of nicotine and cotinine were highest in heavy (>20 cigarette per day) smokers, followed by moderate (<20 cigarette per day) and light (occasional) smokers. In non-smokers nicotine and cotinine concentrations were much higher for pre-shift samples than those of post-shift samples.
Based on the findings, we concluded that a restricted-smoking policy workplace with isolated smoking room could provide protection from ETS exposure if sufficient attention is given to overall system design, air exchange rates, and directional airflow. Otherwise, the accessibility to the smoking room and the education to the staff should also be taken into consideration to avoid the smoking outside the designated areas.