摘要

乾燥行業需求的日益增長推動了新技術和設備的不斷發展,乾燥機在工業領域中具有廣泛的應用。為了提升設備的節能效果,本研究使用商用計算流體力學軟體Ansys Fluent進行三維暫態模擬,對烘箱的熱交換器進行改進,並分析各種鰭片設計對烘箱升溫速率的影響。由於烘箱具有對稱性且為減少運算時間,本研究使用入口為0.1 m × 0.1 m的矩形流道模擬烘箱內部情況。
在研究過程中,調整了三種熱交換器的關鍵參數,分別為鰭片間距、鰭片厚度和加熱管管徑,並將升溫速率和壓降值的結果製成表格進行比較。研究結果顯示,當鰭片厚度固定為1 mm時,鰭片間距從40 mm縮小至2.5 mm,烘箱的升溫速率從0.317 K/s提升至0.827 K/s。此外,加熱管管徑對壓降具有顯著影響。在鰭片間距固定為10 mm,鰭片厚度固定為1 mm的情況下,加熱管管徑從21 mm減小至7 mm,壓降從7621 Pa降低至835 Pa。
這些結果表明,通過改善鰭片設計和加熱管管徑,可以顯著提高烘箱的升溫速率並減少壓降,從而達到節能效果。這對於乾燥行業的技術提升具有重要意義,為未來設備設計提供了參考依據。
The growing demand in the drying industry has driven the continuous development of new technologies and equipment. Dryers have extensive applications in industrial fields. To enhance the energy efficiency of the equipment, this study uses the commercial computational fluid dynamics software Ansys Fluent to perform three-dimensional transient simulations, aiming to improve the heat exchanger of the oven and analyze the effects of various fin designs on the oven's heating rate. Given the symmetry of the oven and to reduce computation time, a rectangular flow channel with an inlet of 0.1 m × 0.1 m is used to simulate the internal conditions of the oven.
During the study, three key parameters of the heat exchanger were adjusted: fin spacing, fin thickness, and heating tube diameter. The results of heating rate and pressure drop were tabulated for comparison. The results show that when the fin thickness is fixed at 1 mm, reducing the fin spacing from 40 mm to 2.5 mm increases the heating rate of the oven from 0.317 K/s to 0.827 K/s. Additionally, the diameter of the heating tube significantly affects the pressure drop. When the fin spacing is fixed at 10 mm and the fin thickness is fixed at 1 mm, reducing the heating tube diameter from 21 mm to 7 mm decreases the pressure drop from 7621 Pa to 835 Pa.
These results indicate that improving fin design and heating tube diameter can significantly increase the heating rate of the oven and reduce the pressure drop, thereby achieving energy savings. This has important implications for technological advancements in the drying industry and provides a reference for future equipment design.