基於日落黃溶致型液晶的BSA、CA125和SARS-CoV-2核殼蛋白的無標記光學與介電生物感測
Label-Free Optical and Dielectric Biosensing of BSA, CA125, and SARS-CoV-2 Nucleocapsid Protein Based on Sunset Yellow Lyotropic Chromonic Liquid Crystal
摘要
本研究旨在開發出一種基於溶致型呈色液晶的生物傳感平台,以應對新型冠狀病毒株(SARS-CoV-2)肆虐的背景下對於病毒的快速檢測與即時檢測的巨大需求。溶致型呈色液晶以其高靈敏度和優秀的生物相容性而受到關注,被視為一種具有潛力的生物檢測平台。本研究選擇了食品染料日落黃作為檢測媒介。在28 wt.%濃度下,日落黃水溶液形成了向列型液晶結構,並在水中形成聚集體,具有液晶光學各向異性和介電各向異性的特性。筆者分別測量了三種待測物的光學和電學響應,包括牛血清蛋白、癌症標誌物CA125和冠狀病毒珠中的核殼蛋白。
首先,筆者以牛血清蛋白為切入點,使用偏振顯微鏡與光纖光譜儀研究了日落黃液晶在生物分子作用下的光學行為變化。接著,筆者研究了CA125的免疫反應行為和時間關係,並探討了CA125抗體對於抗原的選擇專一性。最後,筆者將CA125與人類血清混合,進行了臨床免疫檢測評估。通過瞭解牛血清蛋白和CA125的免疫反應在溶致型液晶中所造成的光學響應,筆者引入核殼蛋白作為待測物,分析核殼蛋白造成日落黃液晶的光學和電學響應,並探討日落黃液晶對核殼蛋白的即時檢測(real-time detection)行為。
結果顯示,垂直排列的日落黃液晶實現了對核殼蛋白濃度的線性光學響應,光學紋理經ImageJ軟體計算分析後,獲得偵測極限為5.5 x 10^(−11) g/mL;而基於日落黃液晶的核殼蛋白電學生物測定,量測了介電頻譜實部(ε')在低頻時(1 Hz)的變化,顯示其偵測極限為1.17 x 10^(−12) g/mL。
觀察了即時免疫分析時日落黃液晶的行為,高濃度的核殼蛋白分子在日落黃液晶水溶液中有更高的效率被固定的抗體捕獲。並且發生特異性結合干擾日落黃液晶聚集體的排列。基於日落黃液晶的生物傳感免疫測定平台可以實現對核殼蛋白的簡單、低成本、高靈敏性的免疫檢測。這一平台具有潛力應用於病毒臨床檢測和即時檢測,對於疫情的控制和預防具有重要意義。
首先,筆者以牛血清蛋白為切入點,使用偏振顯微鏡與光纖光譜儀研究了日落黃液晶在生物分子作用下的光學行為變化。接著,筆者研究了CA125的免疫反應行為和時間關係,並探討了CA125抗體對於抗原的選擇專一性。最後,筆者將CA125與人類血清混合,進行了臨床免疫檢測評估。通過瞭解牛血清蛋白和CA125的免疫反應在溶致型液晶中所造成的光學響應,筆者引入核殼蛋白作為待測物,分析核殼蛋白造成日落黃液晶的光學和電學響應,並探討日落黃液晶對核殼蛋白的即時檢測(real-time detection)行為。
結果顯示,垂直排列的日落黃液晶實現了對核殼蛋白濃度的線性光學響應,光學紋理經ImageJ軟體計算分析後,獲得偵測極限為5.5 x 10^(−11) g/mL;而基於日落黃液晶的核殼蛋白電學生物測定,量測了介電頻譜實部(ε')在低頻時(1 Hz)的變化,顯示其偵測極限為1.17 x 10^(−12) g/mL。
觀察了即時免疫分析時日落黃液晶的行為,高濃度的核殼蛋白分子在日落黃液晶水溶液中有更高的效率被固定的抗體捕獲。並且發生特異性結合干擾日落黃液晶聚集體的排列。基於日落黃液晶的生物傳感免疫測定平台可以實現對核殼蛋白的簡單、低成本、高靈敏性的免疫檢測。這一平台具有潛力應用於病毒臨床檢測和即時檢測,對於疫情的控制和預防具有重要意義。
This study aims to develop a biosensing platform based on lyotropic chromonic liquid crystals (LCLCs) to address the huge demand for rapid detection and real-time monitoring of viruses in the context of the ravages of a novel coronavirus strain (SARS-CoV-2). LCLCs are considered as a promising bioassay platform due to their high sensitivity and excellent bio-compatibility. In this study, a food dye, sunset yellow (SSY), was selected as the detection medium. At a concentration of 28 wt.%, SSY formed a nematic liquid crystal structure and formed aggregates in water with unique liquid crystal optical anisotropy and dielectric anisotropy properties. We measured the optical and electrical responses of three test substances, including bovine serum albumin (BSA), cancer marker CA125, and nucleocapsid protein (N protein) in coronavirus beads, respectively.
First, we studied the optical behavior of SSY in response to biomolecules using polarization microscopy and fiber-optic spectrometer with BSA as the starting point. Then, we investigated the behavioral and temporal relationships of CA125 immunoreactivity and explored the antigen-selective specificity of anti-CA125 antibody. Finally, we mixed CA125 with human serum and performed a clinical immunoassay. By understanding the optical response of lyotropic liquid crystals in BSA and the immune mechanism of CA125, we introduced N protein as the analyte, analyzed the optical and electrical response of SSY-based N protein, and investigated the real-time detection behavior of SSY on N protein.
The results showed that the linear optical response of the vertically aligned SSY to the N protein concentration was achieved, and the optical texture was calculated and analyzed by ImageJ software, and the detection limit of 5.5 x 10^(−11) g/mL was obtained; and the electrical bioassay of N protein based on SSY measured the real part of the dielectric spectrum (ε') at low frequencies (1 Hz) showed a detection limit of 1.17 x 10^(−12) g/mL.
Observing the behavior of SSY during real-time immunoassay, high concentrations of N protein molecules were more efficiently trapped by immobilized antibodies in SSY solution. Also, specific binding interferes with the SSY aggregates alignment. The SSY-based biosensing immunoassay platform enables simple, low-cost, and highly sensitive immunoassays for N protein. This platform has the potential to be applied to clinical detection and real-time surveillance of viruses, which is important for outbreak control and prevention.
First, we studied the optical behavior of SSY in response to biomolecules using polarization microscopy and fiber-optic spectrometer with BSA as the starting point. Then, we investigated the behavioral and temporal relationships of CA125 immunoreactivity and explored the antigen-selective specificity of anti-CA125 antibody. Finally, we mixed CA125 with human serum and performed a clinical immunoassay. By understanding the optical response of lyotropic liquid crystals in BSA and the immune mechanism of CA125, we introduced N protein as the analyte, analyzed the optical and electrical response of SSY-based N protein, and investigated the real-time detection behavior of SSY on N protein.
The results showed that the linear optical response of the vertically aligned SSY to the N protein concentration was achieved, and the optical texture was calculated and analyzed by ImageJ software, and the detection limit of 5.5 x 10^(−11) g/mL was obtained; and the electrical bioassay of N protein based on SSY measured the real part of the dielectric spectrum (ε') at low frequencies (1 Hz) showed a detection limit of 1.17 x 10^(−12) g/mL.
Observing the behavior of SSY during real-time immunoassay, high concentrations of N protein molecules were more efficiently trapped by immobilized antibodies in SSY solution. Also, specific binding interferes with the SSY aggregates alignment. The SSY-based biosensing immunoassay platform enables simple, low-cost, and highly sensitive immunoassays for N protein. This platform has the potential to be applied to clinical detection and real-time surveillance of viruses, which is important for outbreak control and prevention.