以三軸加速規和心率估測日常活動能量消耗

Assessment of Energy Expenditure in Daily Activities Using Accelerometer and Heart Rate

檔案

日期

2008

類型

語言

中文

摘要

本研究為利用微控制器MSP430分析處理一導程心電圖與三軸加速規的訊號,來估測能量消耗。在使用三軸加速規估測能量消耗的部份,本研究改良Chen於1997年提出的利用三軸加速規的積分值轉化為能量消耗值的非線性模型,並利用心跳儲備率(% heart rate reserve) 與耗氧儲備率( reserve)的關係來推估能量消耗,發展一個判斷式去判斷使用者於日常生活中的活動情形,使之更準確判斷在不同活動狀態下,身體活動所消耗的能量消耗值。本系統可讓使用者瞭解自己每天的活動量,以達到自我運動管理的目的。
本研究對20位受測者(年齡26.75 □ 3.13 歲,體重69.00 □ 13.76 kg,身高170.40 □ 7.86 cm,BMI 23.65 □ 3.91)進行三大類日常生活動作能量消耗的估算。第一類為走路(3.2 km/h、4.0 km/h、4.8 km/h)和跑步(9.6 km/h);第二類為上樓梯和下樓梯;第三類為掃地、拖地及擦窗戶。本研究結果與美國運動醫學會(ACSM)2000年所訂定出來各類活動會消耗的標準值相較,走路(3.2 km/h、4.0 km/h、4.8 km/h)和跑步(9.6 km/h)時與標準值誤差分別為0.03 MET、0.02 MET、0.28 MET及0.47 MET;上樓梯為0.7 MET、下樓梯為0.18 MET;掃地為1.32 METs、拖地為1.23 METs 及擦窗戶為0.87 MET。此誤差均在合理範圍,顯示本系統可以確實估測日常生活活動的能量消耗。
The aim of this study is to integrate one-lead ECG and 3-axis accelerative data to improve energy expenditure assessment. Which wishes to quantify the exercise each day and achieve the goal of self-management.Accurate measurement of physical activity is a prerequisite to determine dose-response relationships between activity and health. The combination of heart rate and mobility holds promise for improving the accuracy of physical activity assessment.
The 3-axis accelerometer to estimate energy expenditure is adopted in the study which was developed by Chen in 1997 using the nonlinear model integration methed of 3 axis acceleration for into energy expenditure.We used the relationship between % HR reserve and reserve to calculate energy expenditure. It is expected that combination HR and accelerative signal for
improve the accuracy of assessing energy expenditure .
A total of 20 men and women (26.75 3.13 yr, 69.00 13.76 kg, 170.40 7.86 cm, 23.65 3.91 kg. ) were recruited for this study.
Participants completed three kinds daily activities to verify the analysis outcome. The first kind include walking a three speeds(3.2 km/h,4.0 km/h,4.8 km/h)and jogging (9.6 km/h). The second kind involved climbing upstairs and downstairs. The third kind is to perform sweeping、mopping、cleaning the window. We compare with the guideline of energy expenditure published by ACSM in 2000.In the first kind, the standard error for walking speeds are 0.03 MET,0.02 MET, and 0.28 MET, respectively. The standard error for jogging is 0.47 MET. In the second kind, the standard error for climbing upstairs and dowstairs is 0.70 MET and 0.28 MET, respectively. In the three kind, the standard error for sweeping is 1.32 MET, mopping is 1.23 METs, and cleaning the window is 0.87 MET. The outcome in the study is which the rational range. It reveals that the system can accurately estimate the energy expenditure of daily activities correctly.
顯示完整詮釋資料 統計資料

引用此條目

林其範 (2008). 以三軸加速規和心率估測日常活動能量消耗. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/42376

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/42376