穿戴式慣性感測網路用於巴金森氏症精準上肢運動功能評量與震顫嚴重程度評分系統

Wearable Inertial Sensing Network for Precise Assessment of Upper Limb Motor Function and Tremor Severity Scoring System in Parkinson's Disease

檔案

日期

2024

類型

語言

英文

摘要

巴金森氏症為常見的神經退化性運動障礙疾病,而患者有可能出現的病徵有: 四肢發抖、無力、軀幹駝背、動作遲緩等。為了能客觀評估病患症狀的嚴重程度,統一巴金森氏症量表被廣泛應用於臨床評估,我們將著重於量表第三部分,即運動檢查。由於前述的症狀會對患者日常生活造成眾多不便,我們將專注於手部的運動分析。
我們使用穿戴式慣性測量單元,以取樣頻率50HZ錄製18名患者資料與9位正常受試者資料,並設計出高準確度和低功耗的演算法。對統一巴金森氏症量表運動檢查中上肢的運動項目進行分類、參數計算,同時評估手部震顫情形,並且透過高速光學捕捉系統進行準確度驗證,其平均準確度為90.79%、95.36% 和94.68% (卡帕係數為0.799)。此外,為了達到低功耗與可穿戴式需求,我們根據該演算法實驗了一個晶片,採用台積電0.18微米CMOS製程,晶片功耗為0.0614毫瓦,晶片面積為1.90631毫米X 1.90598毫米。
我們的研究結果顯示,所提出系統可同時監控雙手的運動行為,並且達到高準確要求,以利提供專業人員進行臨床評估。具有潛力提供患者或年長者隨時隨地進行自我檢測,提早發現症狀並及時治療。
Parkinson's disease is a common neurodegenerative motor disorder, with symptoms that may include tremors in the limbs, weakness, stooped posture, and bradykinesia. To objectively assess the severity of these symptoms, the Unified Parkinson's Disease Rating Scale (UPDRS) is widely used in clinical evaluations. Our focus will be on the third part of the scale, which pertains to motor examination. Given that the aforementioned symptoms can cause significant inconvenience in patients' daily lives, we will concentrate on analyzing hand movements.
We used wearable inertial measurement units (IMUs) with a sampling frequency of 50 Hz to record data from 18 patients and 9 healthy subjects. We developed a high-accuracy, low-power algorithm to classify and calculate parameters for upper limb movement tasks from the motor examination section of the Unified Parkinson's Disease Rating Scale (UPDRS). Additionally, we assessed hand tremors and validated the accuracy using a high-speed optical capture system. The average accuracy rates were 90.79%, 95.36%, and 94.68% (the Kappa coefficient is 0.799.).Additionally, to meet the low-power and wearable requirements, we implemented the algorithm on a chip using TSMC's 0.18-micron CMOS process. The chip has a power consumption of 0.0614 milliwatts and a chip area of 1.90631 mm x 1.90598 mm.
Our research results demonstrate that the proposed system can simultaneously monitor the movement of both hands while achieving high accuracy, facilitating clinical assessments by professionals. It allows patients or the elderly to self-monitor anytime, anywhere, enabling early symptom detection and timely treatment.
顯示完整詮釋資料 統計資料

引用此條目

Chen, Y.-H. (2024). Wearable Inertial Sensing Network for Precise Assessment of Upper Limb Motor Function and Tremor Severity Scoring System in Parkinson's Disease. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/4248

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/4248