電盤內氣霧式滅火系統溫度探測器配置優化
Optimization of Temperature Sensor Configuration for Aerosol Fire Extinguishing Systems in Electrical Cabinet.
摘要
依據內政部消防署近年的火災統計,電氣火災被列管的次數位居首位;其中配電盤火災為電氣火災的類型之一。電氣火災為深層火災,滅火特性相較於一般火災更難控制與滅火,針對此設備與環境應更加重視。在各類場所,尤其是工廠,用電需求大於住宅用電,臺灣眾多的工廠中,存在著數量巨大的配電盤配電盤火災的風險也因而相當高。然而,配電盤火災並不容易被發現,也並不容易撲滅;此外,大多數配電盤的內部或附近,不必然設置火災警報系統與自動滅火系統。本研究探討將「氣霧式滅火系統」設置在配電盤內不同位置之效能差異,藉由實驗結果驗證其有效性並作為訂定裝置規範之參考依據。實驗結果顯示,設備設置於配電盤左上方與右上方這兩種配置最佳;設備設置於配電盤中間左邊與中間右邊為條件下可接受,指可燃物高度低於定溫式探測器時,可接受;設備設置於配電盤左下方與右下方為嚴禁禁止設置,指無效設置因素產生。此外,針對新設配電盤體積在0.4m3~10m3之間時,應預留自動滅火設備體積空間,長20cm~35.5cm、寬18cm、深9.7cm~14.4cm。
In recent years, according to disaster statistics from National Fire Agency, the Ministry of the Interior, electrical fire disasters have been listed first in the number of times. This is an issue that all citizens must pay attention to; it is not something that can be solely managed and controlled by fire departments. Based on the Ministry of the Interior's statistics, from 2020 to 2012, the home fire rate was 0.08%, 0.07%, and 0.06%, respectively; similarly, the factory fire rate for the same period was 0.08%,0.07%, and 0.06%. The fire occurrence rates of these two types are similar. In various places, especially factories, the electricity demand is higher than that of residences, and the number of switchboards is relatively larger. However, not all switchboards are equipped with fire alarm systems and automatic fire suppression systems. Electrical fires are deep-seated fires, and their fire extinguishing characteristics are more difficult to control and extinguish compared to ordinary fires. Therefore, more attention should be paid to this equipment and environment. This study will investigate the effectiveness of "Fire Extinguishing Aerosol Systems" installed at various locations within switchboards. The experimental results will be used to verify its effectiveness and serve as a reference for equipment specifications. Experimental results indicate that the optimal configurations for the equipment are placement at the upper left and upper right corners of the distribution board. Placement of the equipment at the middle left and middle right positions of the distribution board is acceptable, provided that the height of combustible materials is below the fixed temperature detector. Placement of the equipment at the lower left and lower right corners of the distribution board is strictly prohibited due to ineffective installation factors. For new switchboards with volume between 0.4 m³ and 10 m³, a reserved space for equipment with dimensions of 20cm to 35.5cm in length, 18cm in width, and 9.7cm to 14.4 cm in depth Fire Systems should be designated.