結合光流深度學習與斑點追蹤應用於三維心臟超音波應變成像

3-D Ultrasound Strain Imaging Using Integrated Speckle Tracking and Deep Learning Optical Flow Techniques

檔案

日期

2024

類型

語言

中文

摘要

Ultrasound cardiac strain imaging is routinely used to quantitatively analyze myocardial deformation during contraction and relaxation. While two-dimensional (2-D) strain imaging is commonly employed in clinical practice, it cannot fully capture myocardial deformations since the heart moves in 3-D. To address this limitation, we previously proposed a 3-D speckle tracking technique with tilt filtering (TF-ST), which enables high-spatial-resolution and accurate 3-D displacement estimation, compensating for deformation-induced speckle decorrelation. However, due to the nature of the ultrasound beam pattern, lateral and elevational displacement estimation errors remain larger than those in the axial direction. Since strain is calculated as the spatial derivative of displacement, these errors become more pronounced when converted into strain values. Recently, optical-flow-based deep learning models developed in computer vision have shown promise and have been applied to 2-D strain imaging. In our previous work, we developed a modified RAFT model called RAFT-US, trained on a large dataset of ultrasound cardiac images, which improved displacement estimation accuracy by a factor of 1.5 to 3 over conventional 2-D speckle tracking. This thesis aims to develop a new 3-D cardiac strain imaging method that combines 2-D RAFT-US with TF-ST. In this hybrid approach, axial displacement is estimated using TF-ST, while non-axial displacements are estimated using RAFT-US. To achieve this, we align multiple images in the lateral-elevational plane by compensating for the estimated axial displacements, followed by lateral and elevational displacement estimation using RAFT-US. We tested our method using both 3-D simulation data and ischemic disease data from adult dogs. Compared to TF-ST, the proposed hybrid 3-D method improves non-axial displacement accuracy by a factor of 1.9 and enhances strain accuracy by 1.3. The results demonstrate significant improvements in both radial strain and principal stretch imaging compared to TF-ST.
心臟超音波應變影像技術用於定量分析心肌在收縮與舒張過程中的形變程度。目前臨床上普遍採用二維(2-D)應變影像來診斷局部病變,由於心臟在三維空間中運動,2-D 技術無法全面捕捉心肌的變形。為了解決這一限制,我們此前提出了三維傾斜濾波器的斑點追蹤技術(TF-ST),技術通過補償變形引起的斑點去相關性,能夠實現高空間解析度和精確的三維位移估計。然而,由於三維影像的幀率較低,加上超音波繞射效應的影響,橫向與仰向位移估計誤差較大。由於應變是位移的空間梯度,這些位移誤差轉換成應變數值時將更加嚴重。近年來,電腦視覺領域的光流深度學習模型已應用於二維應變成像,在我們團隊先前的研究中,開發了一種名為 RAFT-US 的改良 RAFT 模型,該模型在大量超音波心臟影像數據集上進行訓練。在模擬數據的位移估計中,RAFT-US 相較於二維斑點追蹤技術提升了1.5-3倍的準確度。然而,由於尚未開發出三維光流模型,深度學習仍無法完全取代三維斑點追蹤。因此,本研究旨在開發一種新的三維心肌應變成像方法,將二維 RAFT-US 與 TF-ST 結合。在這種混合方法中,軸向位移由 TF-ST 估計,而非軸向位移由 RAFT-US 估計。為此,我們通過補償已估計的軸向位移來對橫向-仰向平面中的多張影像進行對齊,隨後使用 RAFT-US 進行橫向和仰向方向的位移估計。我們使用三維模擬資料以及來自成年犬的缺血性疾病數據測試了我們的方法。與 TF-ST 相比,所提出的混合三維位移估計技術在非軸向位移準確度上提升了1.9倍,而應變精確度則提升1.3倍。透過徑向應變與主應變影像,能以高空間解析度的方式,精確定位局部缺血區域。

所屬典藏

電子研究所
顯示完整詮釋資料 統計資料

引用此條目

謝旻諺 (2024). 結合光流深度學習與斑點追蹤應用於三維心臟超音波應變成像. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/4481

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/4481