評估不同的腦磁振灌流影像後處理演算法所計算出之腦血流流量和平均穿流時間
Evaluation of different Postprocessing Methods for Determination of Cerebral Blood Flow and Mean Transit Time by MR Perfusion Imaging
摘要
血流灌注影像藉由注入顯影劑來觀察血液在腦組織的流動情形,取得顯影劑濃度對連續時間的變化曲線後,計算腦血流動力參數,常使用腦血流體積( CBV )、腦血流流量( CBF ) 、平均穿流時( MTT )…等參數來評估真實腦組織的血流灌注情形,藉此來診斷腦血管狹窄及急性缺血性中風的病灶區域。
本研究目的在於探討不同的演算方法,所計算出之CBF、MTT的正確性,以電腦模擬實驗模擬當對比劑延遲效應( delay effect )存在時,使用最大斜率法( Maximum slope ) 、最大濃度法( Maximum concentration );傅立葉轉換法( Fourier transform ) 、標準奇異值分解法( standard singular value decomposition, sSVD )及環狀奇異值分解法( circular singular value decomposition, cSVD ),所計算出之CBF及MTT數值,以獨立成份分析法(independent component analysis, ICA )將ROI圈選於正常動脈、正常腦實質、不正常動脈、不正常腦實質四個區域,以二維散佈圖來評估各種演算法在臨床血管狹窄病人診斷上之價值。
模擬結果顯示:1) 平均穿流時間短時所有演算方法所計算出的CBF都會有低估的現象;2) sSVD法在有延遲效應存在時低估的情形更為顯著;3) sSVD法所計算之MTT在影像中能提供較佳的對比,利於臨床病灶診斷;4) Maximum slope、Maximum concentration兩種演算法所運算出之CBF、MTT數值和cSVD演算法所計算出之數值相似,且Maximum concentration法受雜訊的影響最小,加上又不需要使用任何繁複的數學運算即可求出,為一簡單又省時的演算方法。臨床影像二維散佈圖結果顯示:1) 正常端動脈及腦實質所計算出之CBF_sSVD數值較不正常端動脈及腦實質所計算出之CBF_cSVD數值來的大;2) 不正常端動脈及腦實質所計算出之MTT _sSVD數值較正常端動脈及腦實質所計算出之MTT _cSVD數值來的長;3) MTT _sSVD在臨床狹窄病人影像上提供較佳的正常側與異常側影像對比。
本研究目的在於探討不同的演算方法,所計算出之CBF、MTT的正確性,以電腦模擬實驗模擬當對比劑延遲效應( delay effect )存在時,使用最大斜率法( Maximum slope ) 、最大濃度法( Maximum concentration );傅立葉轉換法( Fourier transform ) 、標準奇異值分解法( standard singular value decomposition, sSVD )及環狀奇異值分解法( circular singular value decomposition, cSVD ),所計算出之CBF及MTT數值,以獨立成份分析法(independent component analysis, ICA )將ROI圈選於正常動脈、正常腦實質、不正常動脈、不正常腦實質四個區域,以二維散佈圖來評估各種演算法在臨床血管狹窄病人診斷上之價值。
模擬結果顯示:1) 平均穿流時間短時所有演算方法所計算出的CBF都會有低估的現象;2) sSVD法在有延遲效應存在時低估的情形更為顯著;3) sSVD法所計算之MTT在影像中能提供較佳的對比,利於臨床病灶診斷;4) Maximum slope、Maximum concentration兩種演算法所運算出之CBF、MTT數值和cSVD演算法所計算出之數值相似,且Maximum concentration法受雜訊的影響最小,加上又不需要使用任何繁複的數學運算即可求出,為一簡單又省時的演算方法。臨床影像二維散佈圖結果顯示:1) 正常端動脈及腦實質所計算出之CBF_sSVD數值較不正常端動脈及腦實質所計算出之CBF_cSVD數值來的大;2) 不正常端動脈及腦實質所計算出之MTT _sSVD數值較正常端動脈及腦實質所計算出之MTT _cSVD數值來的長;3) MTT _sSVD在臨床狹窄病人影像上提供較佳的正常側與異常側影像對比。
Dynamic susceptibility contrast magnetic resonance imaging is a technique for measuring cerebral blood perfusion. Quantitative calculations on the hemodynamic parameters such as cerebral blood volume ( CBV ) 、 cerebral blood flow ( CBF ) 、and mean transit time ( MTT ) are used for the diagnosis of cerebral vascular diseases, such as stenosis and acute ischemic stroke.
Computer simulation was used to evaluate the effect of tracer delay on the quantification of CBF and MTT using different calculation techniques, including : Maximum slope、Maximum concentration、Fourier transform、standard singular value decomposition ( sSVD ), and circular singular value decomposition ( cSVD ). Scatter plots were used to evaluate parameters calculated for different tissues using these algorithms from clinical images in patients with stenosis. The four tissue types determined from the independent component analysis segmentation were artery on the normal and stenosis sides, and brain parenchyma on the normal and stenosis sides.
Our simulation results indicate that:1) CBF were underestimated for short MTTs in all calculation techniques;2) sSVD is sensitive to tracer time delay;3) MTT_sSVD may provide high contrast for clinical diagnosis;4) CBF and MTT calculated by Maximum slope and Maximum concentration algorithms are similar to cSVD. The Maximum concentration algorithm is not only less sensitive to noise, but also easy to calculate without any complicated calculation. Scatter plot analysis of clinical images indicate that:1) the CBF_sSVD values for artery and brain parenchyma at the normal side were higher than CBF_cSVD values; 2) the MTT _sSVD values for artery and brain parenchyma at the abnormal side were longer than MTT _cSVD values; 3) MTT _sSVD may provide high contrast for clinical images in patients with stenosis.
Computer simulation was used to evaluate the effect of tracer delay on the quantification of CBF and MTT using different calculation techniques, including : Maximum slope、Maximum concentration、Fourier transform、standard singular value decomposition ( sSVD ), and circular singular value decomposition ( cSVD ). Scatter plots were used to evaluate parameters calculated for different tissues using these algorithms from clinical images in patients with stenosis. The four tissue types determined from the independent component analysis segmentation were artery on the normal and stenosis sides, and brain parenchyma on the normal and stenosis sides.
Our simulation results indicate that:1) CBF were underestimated for short MTTs in all calculation techniques;2) sSVD is sensitive to tracer time delay;3) MTT_sSVD may provide high contrast for clinical diagnosis;4) CBF and MTT calculated by Maximum slope and Maximum concentration algorithms are similar to cSVD. The Maximum concentration algorithm is not only less sensitive to noise, but also easy to calculate without any complicated calculation. Scatter plot analysis of clinical images indicate that:1) the CBF_sSVD values for artery and brain parenchyma at the normal side were higher than CBF_cSVD values; 2) the MTT _sSVD values for artery and brain parenchyma at the abnormal side were longer than MTT _cSVD values; 3) MTT _sSVD may provide high contrast for clinical images in patients with stenosis.