放射線標誌微粒體與聚合血清白蛋白

Characterization of 68Ga/111In-SIR-Spheres® as a novel PET/SPECT imaging surrogate of 90Y-SIR-Spheres® and compared with 99mTc-MAA in an orthotopic hepatoma animal model

檔案

日期

2010

類型

語言

中文

摘要

目的:釔-90 SIR-Spheres®配合選擇性體內放射療法(SIRT)可以提高肝癌病人存活率甚至消滅腫瘤。釔-90為純貝他粒子放射核種,不易偵測其在體內之分布。臨床上常用鎝-99m標幟聚集血清白蛋白(99mTc-MAA)預測釔-90 SIR-Spheres®於人體內之分布,並據以評估腫瘤及正常器官之輻射劑量。本研究發展銦-111/鎵-68-SIR-Spheres®(111In/68Ga-SIR-Spheres®)作為釔-90 SIR-Spheres®(90Y-SIR-Spheres®)的正子及加馬閃爍造影替代劑,評估SIR-Spheres®於荷肝腫瘤大鼠之生物特性,並比較其與99mTc-MAA之差異。
方法與材料:已衰變無活性的釔-90 SIR-Spheres®加入銦-111及鎵-68後於室溫下反應30 分鐘,經溼熱滅菌後可得到高標誌效率與高放射化學純度(皆>95%)的111In/68Ga-SIR-Spheres®。將N1-S1細胞株植入SD大鼠10天後(肝腫瘤直徑約1公分),開始進行後續生物實驗。將健康大鼠經尾靜脈注射111In/68Ga-SIR-Spheres®後進行微型正子造影,測量放射藥物在體內穩定度。荷肝腫瘤大鼠經肝動脈混合注射68Ga-SIR-Spheres®與99mTc-MAA或是111In-SIR-Spheres®後,進行生物分布、微型正子放射斷層影像、平面加馬攝影及自動放射攝影術(autoradiography)等實驗,評估其生物特性。
結果:111In/68Ga-SIR-Spheres®的放射化學產率與純度皆大於95%,標幟及滅菌過程可在1個小時內完成,標幟前後微球體之粒徑大小無顯著性差異(標幟前:30.1±9.1□m vs.標幟後:30.1±6.0 □m)。 111In/68Ga- SIR-Spheres®在胎牛血清中穩定度(in vitro stability)於52及3小時皆仍大於90%;兩藥物於大鼠體內各經過24及1小時後,穩定度(in vivo stability)皆仍大於90%。經由肝動脈將68Ga-SIR-Spheres®與99mTc-MAA一起注入荷肝腫瘤大鼠後,生物分布實驗結果顯示兩者之腫瘤/肝臟比(tumor/liver ratio, r2=0.35, n=8)與腫瘤/肺臟比(tumor/lung ratio, r2=0.31, n=8)皆無顯著相關性。相對於一起注射68Ga-SIR-Spheres®與111In-SIR-Spheres®之對照組,腫瘤/肝臟比值呈現極高度相關(r2=0.99, n=6),此結果顯示SIR-Spheres®與99mTc-MAA在荷肝腫瘤大鼠體內的生物特性並不一致。顯微鏡觀察與粒徑分析檢測(99mTc-MAA 顆粒大小26.6±18.2 μm),兩藥物顆粒大小與形狀明顯不同,可能是造成生物體內分布差異的主因。
結論:本研究發展之111In/68Ga-SIR-Spheres®有良好的體內穩定度,可作為釔-90 SIR-Spheres®的PET與SPECT/Planar gamma 造影替代劑。若與釔-90 SIR-Spheres®混合施打,可於注射後短時間內評估釔-90 SIR-Spheres®於肝腫瘤與正常組織實際分布狀態,使SIRT治療更為安全,劑量估算更精確。
Objectives: 90Y-SIR-Spheres® are currently used in the treatment of solid liver tumors. However, they cannot be clearly imaged in vivo post injection. Gamma imaging with 99mTc-MAA is currently adopted to predict the distribution of 90Y-SIR-Spheres® in vivo. This study aims to develop a novel 68Ga/111In-SIR-Spheres® as PET/SPECT imaging surrogate for distribution assessment and radiation dose estimation of 90Y-SIR-Spheres®. The distribution pattern of 68Ga-SIR-Spheres® and 99mTc-MAA was also evaluated.
Methods: 68Ga/111In-SIR-Spheres® were prepared with high radiochemical yield and radiochemical purity (both >95%) after incubating 90Y-SIR-Spheres® with 68GaCl3 or 111InCl3. The in-vivo stability of 68Ga/111In-SIR-Spheres® was assessed based on the small animal PET/gamma imaging of normal SD rats after i.v. injection of radiotracers. The biodistribution study and PET/SPECT/CT imaging were performed in N1S1 hepatoma-bearing SD rats after intra-hepatic artery (i.a.) co-injection of 68Ga-SIR-Spheres® and 99mTc-MAA.
Results: 68Ga- and 111In-SIR-Spheres® has the same size distribution (30.1±6.0 μm), similar to that of 90Y-SIR-Spheres® (30.1±9.1μm), and both showed good in vivo stability (> 90% at 1 h and 80% at 78 h, respectively). The tumor-to-liver ratios determined in biodistribution studies of 68Ga-SIR-Spheres® and 99mTc-MAA showed only weak correlation (r2=0.35, n=8). Similar results were found for the tumor-to-lung ratio (r2=0.31, n=8) after i.a. co-injection of 68Ga-SIR-Spheres® and 99mTc-MAA. However, co-injection of 68Ga-SIR-Spheres® and 111In-SIR-Spheres® resulted in highly correlated particle distribution in tumor and liver with a r2 of 0.997 (tumor-to-liver ratio).
Conclusion: Significantly different distribution pattern between 68Ga-SIR-Spheres® and 99mTc-MAA (size distribution 26.6±18.2 μm) were observed, probably due to the difference in the size and the shape between radiolabeled SIR-Spheres® and 99mTc-MAA. Our study clearly indicated that 99mTc-MAA is not an ideal imaging surrogate of 90Y-SIR-Spheres® in the orthotopic hepatoma animal model.
顯示完整詮釋資料 統計資料

引用此條目

張添貴 (2010). 放射線標誌微粒體與聚合血清白蛋白. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/44971