非對稱硬度氣墊鞋底於正常膝關節內收力矩之影響
Effect of air-cushion shoe sole with asymmetric stiffness on knee adduction moment in healthy subjects
摘要
背景與目的:。退化性膝關節炎患者由於其內側膝關節局部受力過大、軟骨磨損、膝內翻變形、造成疼痛及影響日常活動。生物力學研究以膝內收力矩來代表膝關節內側受力大小,並應用於臨床上用以改善退化性膝關節炎症狀之矯具,如膝外翻支架及外側楔形鞋墊。然而此類矯具僅減少地面反作用力到膝關節中心的距離,未有同時考量降低地面反作用力衝擊及負載速率之設計。因此,此實驗的目的為探討氣墊鞋底之吸震特性,以及提高外側硬度後對膝關節內收力矩之影響。實驗設計與方法:控制組鞋具為EVA鞋底、氣墊組鞋具為全氣墊鞋底、非對稱組鞋具為提高外側硬度之氣墊鞋底。三款鞋具皆以材料測試機給予週期性壓縮,計算內外側鞋底之能量散失率。受試者共二十六位健康年輕人(十三位男性、十三位女性)。以光學反射式三維動作分析系統紀錄受試者之步態參數、地面反作用力,並估算膝關節、踝關節於額狀面之力矩。測量結果利用獨立t檢定來比較受試者之間步態參數有無異同;及以重複變異數分析來檢定穿著不同款鞋具時步態參數有無差異。結果:週期性壓縮測試顯示非對稱硬度氣墊鞋之外側硬度接近於控制組鞋具、內側能量散失率接近於全氣墊鞋具。步態分析結果顯示非對稱硬度氣墊鞋底和全氣墊鞋底與控制組相比皆能顯著降低膝內收力矩峰值及衝量,而非對稱硬度氣墊鞋降低效果更為顯著。穿著控制組鞋具時膝內收力矩峰值愈高之受試者在穿著非對稱硬度氣墊鞋後峰值降低得愈多。討論與結論: 本實驗的材料測試結果證明氣墊鞋底在提高外側硬度之後,仍保有高能量散失率之特性及提供外側楔形鞋底之效果。步態分析亦支持非對稱硬度氣墊鞋底能降低內側膝關節受力,並且不會造成步頻及地面反作用力負載速率的改變。而介入之前的膝內收力矩峰值可成為未來篩選受試者的參考因素。本實驗結果顯示氣墊鞋底在改變硬度後可降低膝內收力矩峰值及衝量,可成為降低行走時內側膝關節受力之介入工具之一。
Background and purpose: Medial tibiofemoral osteoarthritis is a major medical and economic problem among elderly. To reduce the side-effect of lateral wedge, a shoe modification was proposed for decreasing the loading of medial tibiofemoral compartment by elevating the stiffness of lateral outsoles. However, no study was found to investigate the effect of shock absorptive material combined with asymmetric stiffness on the medial compartment loading. We therefore aimed to examine the efficiency of modified air-cushion outsole with elevated lateral heel stiffness in reducing medial knee loading during normal walking. Methods: Twenty-six healthy subjects were recruited for gait analysis. Three-dimensional kinetic and kinematic data of lower extremity were collected. Testing shoes included a sneaker with EVA shoe sole as control shoes, an air-cushion shoe sole, and an air-cushion shoe sole with the lateral air-sacs injected with hot melt adhesive to elevate the stiffness. The stiffness of the lateral and medial shoe sole was examined by using a material testing machine. One-way ANOVA was used to compare the variables among the testing shoes. Results: The load-unload curves revealed that the air-cushion shoe sole with asymmetric stiffness had higher lateral stiffness, which was similar to the control shoes; and greater energy dissipation ratio in the medial heel, which was similar to the total air-cushion shoes. The peak knee adduction moment and impulse were significantly reduced in wearing the air-cushion with asymmetric stiffness shoe sole compared to the control and the air-cushion groups. A negative correlation between peak knee adduction moment in control shoes and the reduction of the peak knee adduction moment in wearing air-cushion with asymmetric stiffness shoes was found. Discussion and conclusion: The material testing proved that the modification of air-cushion shoe sole remained the features of high energy dissipation ration and provided lateral wedge effect via the elevated lateral stiffness. In gait analysis, the air-cushion shoe sole with asymmetric stiffness reduced the loading of the medial knee joint without altered cadence and ground reaction loading rate. The peak knee adduction moment prior to wearing intervention shoes could be a consideration of subject screening. Our results indicated that the air-cushion shoe sole with altered stiffness could be a useful intervention for reducing the peak adduction moment in medial compartment of knee joint during level walking.