主動式惠斯通電橋電路補償設計

An Active Compensation Design for Wheatstone Bridge Circuit

檔案

日期

2024

類型

語言

中文

摘要

本研究針對先前實驗室設計製作的微共振器系統中的干擾問題,提出一套主動補償電路設計。此干擾問題來自於惠斯通電橋電阻不匹配,導致系統內部的干擾訊號振幅遠大於共振器訊號60dB。因此,本研究利用比例-積分(PI)控制器的積分特性,主動追蹤電橋兩臂之間的分壓比例,並透過全差動運算放大器進行補償,從而減少電阻不匹配所造成的干擾。該設計的挑戰在於需使用乘法器,而乘法器的操作點又必須滿足製程的供應電壓條件,進一步增加了設計的複雜性。
經Simulink模擬與市售元件驗證,補償電路都能夠將電阻不匹配引起的干擾訊號縮小。然而,在台積電0.35μm製程下線後,部分補償電路功能正常,但因製程變異,乘法器的操作點難以實現精確控制,且全差動運算放大器在輸入高頻訊號時,出現相位落後現象,導致部分電路性能未達預期。
因此,本研究設計的補償電路在模擬與初步驗證階段成功降低了干擾訊號,但在實際應用和製程下線後仍需針對乘法器進行優化與調整,以確保其在實際應用中的穩定性與準確性。
This research proposes an active compensation circuit design to address interference issues in a resonator system. The interference arises from mismatched resistors in the Wheatstone bridge, causing the amplitude of the interference signal within the system to exceed the resonator signal by 60dB. Therefore, this study uses a proportional-integral (PI) controller to actively track the voltage division ratio between the two arms of the bridge and compensates through a fully differential operational amplifier to reduce the interference caused by resistor mismatch. A design challenge arises in the need for a multiplier, whose operating point must also satisfy the process supply voltage conditions, adding further complexity to the design.
After verification by Simulink simulation and commercially available components, the compensation circuit successfully reduced the interference signal caused by resistor mismatch. However, following tape-out with the TSMC 0.35μm process, while certain compensation circuit functions operated as intended, process variations introduced challenges in achieving precise control of the multiplier's operating point. Additionally, the fully differential operational amplifier exhibited phase lag when subjected to high-frequency input signals, resulting in some circuit performance not meeting the expected standards.
Therefore, the compensation circuit designed in this research successfully reduced interference signals during simulation and initial validation stages. but the multiplier still needs to be optimized and adjusted to ensure its stability and accuracy in practical applications.