局部排氣裝置對粉塵作業環境之效益分析–以某橡膠製造工廠為例
Analysis of The Benefits of Local Exhaust Ventilation on Dust Working Environments–A Case Study of One Rubber Manufacturing Factory
摘要
事業單位在製程中產生的有害物在工作環境累積、未妥善排除,勞工將會暴露在過量有害物質環境中,造成健康危害。本研究以工程控制方法,對研究對象南部地區某橡膠製造工廠之工廠原料加工等粉塵作業區域,裝設局部排氣裝置及改良既有局部排氣裝置,並比較改善前後之第四種總粉塵作業環境監測結果、作業環境風速、煙流測試結果,分析局部排氣裝置對粉塵作業環境之改善效益。
研究結果發現在碳酸鈣、橡膠粉塵作業環境中裝設局部排氣裝置,開練機處粉塵濃度自平均0.726 mg/m3降低至平均0.394 mg/m3,開練機操作人員粉塵吸入濃度自平均1.43 mg/m3降低至平均0.216 mg/m3,能夠有效降低作業環境中的粉塵濃度,並使作業勞工吸入之粉塵量也降低;在既有局部排氣裝置外圍環境加裝垂簾,將作業環境流場與周圍環境區域流場隔開後,密練機處粉塵濃度自平均2.055 mg/m3降低至平均0.231 mg/m3,密練機操作人員粉塵吸入濃度自平均1.5 mg/m3降低至平均0.138 mg/m3,可優化局部排氣裝置效果,將作業環境中的粉塵濃度及作業勞工的吸入粉塵量降至更低。使用作業環境監測方法做為風險評估工具,可判斷作業環境中的汙染物濃度,及勞工暴露於汙染物之程度;使用煙流測試方法,對事業單位成本壓力較小,又可明確判斷作業環境中的流場流動方向、流動情形,可做為實務上檢視局部排氣裝置效果之簡易可視化工具;使用風速測量方法,測量數值跳動區間較大、易受位置影響,且只能記錄瞬間數值,無法得出長時間之平均值,故實務上僅能輔助檢視局部排氣裝置裝設過程中及裝設後的結果是否有未符合預期設計之情形。
研究結果發現在碳酸鈣、橡膠粉塵作業環境中裝設局部排氣裝置,開練機處粉塵濃度自平均0.726 mg/m3降低至平均0.394 mg/m3,開練機操作人員粉塵吸入濃度自平均1.43 mg/m3降低至平均0.216 mg/m3,能夠有效降低作業環境中的粉塵濃度,並使作業勞工吸入之粉塵量也降低;在既有局部排氣裝置外圍環境加裝垂簾,將作業環境流場與周圍環境區域流場隔開後,密練機處粉塵濃度自平均2.055 mg/m3降低至平均0.231 mg/m3,密練機操作人員粉塵吸入濃度自平均1.5 mg/m3降低至平均0.138 mg/m3,可優化局部排氣裝置效果,將作業環境中的粉塵濃度及作業勞工的吸入粉塵量降至更低。使用作業環境監測方法做為風險評估工具,可判斷作業環境中的汙染物濃度,及勞工暴露於汙染物之程度;使用煙流測試方法,對事業單位成本壓力較小,又可明確判斷作業環境中的流場流動方向、流動情形,可做為實務上檢視局部排氣裝置效果之簡易可視化工具;使用風速測量方法,測量數值跳動區間較大、易受位置影響,且只能記錄瞬間數值,無法得出長時間之平均值,故實務上僅能輔助檢視局部排氣裝置裝設過程中及裝設後的結果是否有未符合預期設計之情形。
In workplaces, harmful substances generated during processes can accumulate in the work environment and, if not properly removed, expose workers to excessive harmful substances, resulting in health hazards. This study employs engineering control methods to install local exhaust ventilation and improve the existing exhaust system in the raw material processing and dust operation areas of a rubber manufacturing plant in southern Taiwan. By comparing the monitored results of total dust concentrations, airspeed in the working environment, and smoke test results before and after improvements, this study analyzes the effectiveness of local exhaust ventilation in enhancing the dust operation environment.
Research results have found that installing local exhaust ventilation in work environments with calcium carbonate and rubber dust reduced dust concentrations around the open mill from an average of 0.726 mg/m³ to 0.394 mg/m³, while the inhaled dust concentration for open mill operators decreased from an average of 1.43 mg/m³ to 0.216 mg/m³. This indicates that the device effectively reduces dust concentrations in the work environment and minimizes the amount of dust inhaled by workers. By adding curtains around the existing local exhaust ventilation system to separate the airflow of the work environment from that of the surrounding area, dust concentration at the closed plastic mixer was reduced from an average of 2.055 mg/m³ to 0.231 mg/m³, and the dust inhalation concentration for closed plastic mixer operators decreased from an average of 1.5 mg/m³ to 0.138 mg/m³. This approach further optimizes the effectiveness of the local exhaust system, significantly reducing dust concentrations in the work environment and the amount of dust inhaled by workers.
Using workplace environmental monitoring methods as a risk assessment tool can determine the concentration of pollutants in the work environment and the extent of workers’ exposure to these pollutants. Smoke flow testing is a cost-effective method for businesses, providing a clear assessment of the airflow direction and movement within the workplace and serving as a simple, visual tool for evaluating the effectiveness of local exhaust ventilation. However, air velocity measurement methods show considerable fluctuations, are easily affected by position, and only record instantaneous values, making it difficult to obtain long-term averages. Therefore, practically, it can only serve as an auxiliary check during and after the installation of local exhaust systems to ensure alignment with the intended design.
Research results have found that installing local exhaust ventilation in work environments with calcium carbonate and rubber dust reduced dust concentrations around the open mill from an average of 0.726 mg/m³ to 0.394 mg/m³, while the inhaled dust concentration for open mill operators decreased from an average of 1.43 mg/m³ to 0.216 mg/m³. This indicates that the device effectively reduces dust concentrations in the work environment and minimizes the amount of dust inhaled by workers. By adding curtains around the existing local exhaust ventilation system to separate the airflow of the work environment from that of the surrounding area, dust concentration at the closed plastic mixer was reduced from an average of 2.055 mg/m³ to 0.231 mg/m³, and the dust inhalation concentration for closed plastic mixer operators decreased from an average of 1.5 mg/m³ to 0.138 mg/m³. This approach further optimizes the effectiveness of the local exhaust system, significantly reducing dust concentrations in the work environment and the amount of dust inhaled by workers.
Using workplace environmental monitoring methods as a risk assessment tool can determine the concentration of pollutants in the work environment and the extent of workers’ exposure to these pollutants. Smoke flow testing is a cost-effective method for businesses, providing a clear assessment of the airflow direction and movement within the workplace and serving as a simple, visual tool for evaluating the effectiveness of local exhaust ventilation. However, air velocity measurement methods show considerable fluctuations, are easily affected by position, and only record instantaneous values, making it difficult to obtain long-term averages. Therefore, practically, it can only serve as an auxiliary check during and after the installation of local exhaust systems to ensure alignment with the intended design.