地下水抽出及處理法整治效率評估
Assessment of Efficiency of Groundwater Remediation by Pump And Treat Method
摘要
本研究以國內某氯乙烯污染場址為例,運用地下水污染傳輸的數值模式模擬,探討水力控制對於整治效率的影響。該場址的污染物涵蓋第一含水層、滯水層及第二含水層,且逐漸擴散至場址外圍。為了解場址地下水污染的傳輸概況,使用GMS MODFLOW 搭配 MT3DMS 數值模擬模式進行建模,並研討不同抽水井以及注水井配置對於整治效率的影響。研究結果顯示,在未進行整治的情況下,污染物持續擴散至場址外圍及滲透至更深的地層中。接著,透過模擬評估地下水抽出及處理法和搭配注水優化水力控制之整治效率。研究結果顯示,若僅利用抽水處理整治,在各層均進行抽水整治效率較佳。此外,利用注水井提升整治效率的方案中,在滯水層中加入注水井時,搭配原先該層的抽水井,能更有效提高整治效率。
In this research, the efficiency of groundwater remediation by pump-and-treat method at a specific known site whose groundwater had been contaminated by chlorinated solvents was assessed by numerical simulation. The contaminants at the site had been released into the uppermost aquifer, then to the aquitard, and lastly to another aquifer underneath. The contaminant plume slowly migrated away from the site due to natural flow. The groundwater simulation program GMS MODFLOW along with the MT3DMS package was utilized to simulate and analyze various conditions of groundwater flow. Furthermore, the efficiency of remediation schemes by setting up of pumping well and injection well at different locations and flow rate was evaluated. According to the result, the contaminants that remained in the areas flowed out of the site and penetrated deeper into the subsurface layers if no remedial action had been impleneuted. However, through pump-and-treat of the contaminated groundwater, effective cleanup could be achieved as demonstrated by simulations. Furthermore, the pumping and injection in the aquitard significantly improved the efficiency of remediation.