The Chemical Composition and Oxidative Potential in Different Sizes of Atmospheric Particles in Northern and Central Taiwan
臺灣北部及中部不同粒徑大氣懸浮微粒化學組成及氧化潛勢探討
Abstract
根據污染來源及粒徑大小尺寸的不同,懸浮微粒具有不同的成分組成及化學特性,粒徑較小之懸浮微粒容易吸附更多的有毒物種,對人體造成健康危害,然而對於PM1.0之研究與相關調查相對較少,且PM1.0也無相對應之排放濃度建議值。故本研究主要針對臺灣工業區進行不同粒徑大氣懸浮微粒(PM1.0、PM2.5及TSP)中化學成分的探討,同時比較北部、中部工業測站及交通測站細懸浮微粒(PM2.5)中化學成分的變化,使用正矩陣因子法解析潛在貢獻源,最後利用「全時細胞分析系統」 (Real time cellular analysis system, RTCA) 測量細胞存活率,以及使用化學氧化壓力方法「二硫蘇糖醇測定」(Dithiothreitol assay) 評估不同粒徑懸浮微粒所造成之氧化潛勢 (OPV及OPM)。
研究結果顯示,北部工業測站中PM1.0、PM2.5及TSP微粒質量濃度範圍分別為8.33-16.2 μg/m3、21.4-30.3 μg/m3及37.5-96.5 μg/m3,PM1.0/PM2.5比率範圍介於0.399-0.526之間。不同粒徑微粒中化學成分濃度冬季皆大於夏季,冬季PM1.0、PM2.5及TSP戴奧辛毒性當量濃度分別為16.6 ± 12.1、14.2 ± 10.8及8.34 ± 6.51 fg TEQWHO/m3,每克微粒中的戴奧辛毒性含量則是以PM1.0 (526.3 ± 422.1 pg TEQWHO/g)最高,其次為PM2.5及TSP。戴奧辛在固態樣品(Particle phase)中皆以高氯數之OCDF及1,2,3,4,6,7,8-HpCDF為主,而氣態樣品(Vapor phase)中則是以低氯數PCDF為主;在中部工業及交通測站中發現PM2.5中戴奧辛以OCDD為主要物種。冬季PM1.0、PM2.5及TSP金屬濃度分別為773±384、2,115±696及12,069±1,637 ng/m3,粗微粒及細微粒中金屬特徵物種不同,在TSP中以地殼元素Na為特徵物種,細微粒中則係Zn、K等金屬元素有較高的佔比。冬季水溶性陰、陽離子濃度分別為5.67±1.26、7.02±1.55及22.9±3.69 μg/m3,且粗微粒及細微粒中離子成分有不同的組成分布,粗微粒中以Cl-及Na+為主,而PM1.0及PM2.5中則是以nss-SO42-、NH4+及NO3-為主;在中部測站比較中發現PM2.5中離子以NH4+為同樣為工業測站的主要物種之一,而交通測站nss-K+含量則明顯較工業測站高。使用PMF進行不同粒徑懸浮微粒中戴奧辛之潛在貢獻源解析,PM1.0主要貢獻為固定污染源,分別為焚化廠(20.0%)、電弧爐煉鋼廠(25.0%)及工業鍋爐(55.0%),PM2.5潛在貢獻源分別為露天燃燒(30.0%)、交通源排放(40.0%)及工業鍋爐(30.0%),而TSP三中潛在貢獻源則分別為焚化廠(32.0%)、工業鍋爐(57.0%)及交通源排放(11.0%);中部工業測站中PM2.5中戴奧辛解析出四種潛在貢獻源,分別為二次練鋅廠(35.0%)、電弧爐煉鋼廠(20.0%)、焚化廠(27.0%)及火葬場(17.0%),交通測站解析出三種潛在貢獻源,分別為露天燃燒(37.0%)、焚化廠(46.0%)及交通排放(16.0%)。
利用A549細胞進行RTCA試驗,所得出結果趨勢為微粒質量越高所造成之細胞存活率越低。進一步使用化學氧化壓力方式評估不同粒徑懸浮中氧化潛勢,結果顯示TSP中OPV值最高,而PM1.0約等同於PM2.5;OPM結果則是顯示粒徑愈小之微粒每單位微粒質量所造成之氧化潛勢愈高(PM1.0>PM2.5>TSP)。不同污染源PM2.5中OPV並無明顯差異,OPM結果則為交通測站較工業測站高。不同粒徑之懸浮微粒質量濃度皆和OPM呈現負相關,說明OPM主要與微粒中污染來源成分有關,而非單純受質量濃度影響。金屬成分與氧化潛勢之相關性比較中,OPV與不同粒徑微粒中Cu皆呈現正相關,其主要原因為Cu為主要造成DTT氧化還原的物種之一,而Fe則因為在大氣環境中濃度較高,故與粒徑大於2.5 μm之微粒中氧化潛勢呈現中度至高度正相關。水溶性陰陽離子與氧化潛勢相關性比較中發現,細微粒(PM1.0及PM2.5)中之氧化潛力主要由NO3-所貢獻,並從結果中推論TSP中造成氧化潛勢之物種可能主要由細懸浮微粒所貢獻;由不同PM2.5測站中比較得出北部工業測站PM2.5氧化潛勢中主要氧化潛勢貢獻物種為nss-Ca2+、nss-Mg2+及NO3-,而中部污染源(工業及交通測站)之氧化潛勢主要貢獻則為nss-SO42-。
研究結果顯示,北部工業測站中PM1.0、PM2.5及TSP微粒質量濃度範圍分別為8.33-16.2 μg/m3、21.4-30.3 μg/m3及37.5-96.5 μg/m3,PM1.0/PM2.5比率範圍介於0.399-0.526之間。不同粒徑微粒中化學成分濃度冬季皆大於夏季,冬季PM1.0、PM2.5及TSP戴奧辛毒性當量濃度分別為16.6 ± 12.1、14.2 ± 10.8及8.34 ± 6.51 fg TEQWHO/m3,每克微粒中的戴奧辛毒性含量則是以PM1.0 (526.3 ± 422.1 pg TEQWHO/g)最高,其次為PM2.5及TSP。戴奧辛在固態樣品(Particle phase)中皆以高氯數之OCDF及1,2,3,4,6,7,8-HpCDF為主,而氣態樣品(Vapor phase)中則是以低氯數PCDF為主;在中部工業及交通測站中發現PM2.5中戴奧辛以OCDD為主要物種。冬季PM1.0、PM2.5及TSP金屬濃度分別為773±384、2,115±696及12,069±1,637 ng/m3,粗微粒及細微粒中金屬特徵物種不同,在TSP中以地殼元素Na為特徵物種,細微粒中則係Zn、K等金屬元素有較高的佔比。冬季水溶性陰、陽離子濃度分別為5.67±1.26、7.02±1.55及22.9±3.69 μg/m3,且粗微粒及細微粒中離子成分有不同的組成分布,粗微粒中以Cl-及Na+為主,而PM1.0及PM2.5中則是以nss-SO42-、NH4+及NO3-為主;在中部測站比較中發現PM2.5中離子以NH4+為同樣為工業測站的主要物種之一,而交通測站nss-K+含量則明顯較工業測站高。使用PMF進行不同粒徑懸浮微粒中戴奧辛之潛在貢獻源解析,PM1.0主要貢獻為固定污染源,分別為焚化廠(20.0%)、電弧爐煉鋼廠(25.0%)及工業鍋爐(55.0%),PM2.5潛在貢獻源分別為露天燃燒(30.0%)、交通源排放(40.0%)及工業鍋爐(30.0%),而TSP三中潛在貢獻源則分別為焚化廠(32.0%)、工業鍋爐(57.0%)及交通源排放(11.0%);中部工業測站中PM2.5中戴奧辛解析出四種潛在貢獻源,分別為二次練鋅廠(35.0%)、電弧爐煉鋼廠(20.0%)、焚化廠(27.0%)及火葬場(17.0%),交通測站解析出三種潛在貢獻源,分別為露天燃燒(37.0%)、焚化廠(46.0%)及交通排放(16.0%)。
利用A549細胞進行RTCA試驗,所得出結果趨勢為微粒質量越高所造成之細胞存活率越低。進一步使用化學氧化壓力方式評估不同粒徑懸浮中氧化潛勢,結果顯示TSP中OPV值最高,而PM1.0約等同於PM2.5;OPM結果則是顯示粒徑愈小之微粒每單位微粒質量所造成之氧化潛勢愈高(PM1.0>PM2.5>TSP)。不同污染源PM2.5中OPV並無明顯差異,OPM結果則為交通測站較工業測站高。不同粒徑之懸浮微粒質量濃度皆和OPM呈現負相關,說明OPM主要與微粒中污染來源成分有關,而非單純受質量濃度影響。金屬成分與氧化潛勢之相關性比較中,OPV與不同粒徑微粒中Cu皆呈現正相關,其主要原因為Cu為主要造成DTT氧化還原的物種之一,而Fe則因為在大氣環境中濃度較高,故與粒徑大於2.5 μm之微粒中氧化潛勢呈現中度至高度正相關。水溶性陰陽離子與氧化潛勢相關性比較中發現,細微粒(PM1.0及PM2.5)中之氧化潛力主要由NO3-所貢獻,並從結果中推論TSP中造成氧化潛勢之物種可能主要由細懸浮微粒所貢獻;由不同PM2.5測站中比較得出北部工業測站PM2.5氧化潛勢中主要氧化潛勢貢獻物種為nss-Ca2+、nss-Mg2+及NO3-,而中部污染源(工業及交通測站)之氧化潛勢主要貢獻則為nss-SO42-。
Suspended particulate matter (PM) varies in composition and chemical properties based on its sources and particle size. Fine particle matters with smaller particle sizes tends to carry more toxic substances, posing health hazards to humans. However, research and investigations regarding PM1.0 were relatively limited, and there is no emission standard for PM1.0. This study focused on investigating the chemical components of atmospheric PM (including PM1.0, PM2.5, and TSP) in local industrial areas, and compared the chemical composition variations of fine particulates (PM2.5) between northern and central industrial site and traffic site. Using positive matrix factorization (PMF) to identify potential sources of pollutants, and took the Real-Time Cell Analysis (RTCA) to measure cell viability. Additionally, using the Dithiothreitol (DTT) assay to assess the oxidative potential (OPV and OPM) of different size particles.
The results revealed that the mass concentrations of PM1.0, PM2.5, and TSP in the northern industrial site range from 8.33 to 16.2 μg/m3, 21.4 to 30.3 μg/m3, and 37.5 to 96.5 μg/m3, respectively, with a PM1.0/PM2.5 ratio ranging from 0.399 to 0.526. The chemical component concentrations in different size particles were higher in winter compared to summer. The concentrations of PCDD/Fs in PM1.0, PM2.5, and TSP were 16.6 ± 12.1, 14.2 ± 10.8, and 8.34 ± 6.51 fg TEQWHO/m3, respectively in winter. The highest dioxin toxicity per gram of particles was in PM1.0 (526.3 ± 422.1 pg TEQWHO/g), followed by PM2.5 and TSP. PCDD/Fs in particle phase were mainly OCDF and 1,2,3,4,6,7,8-HpCDF with high chlorine numbers, while vapor phase predominantly contain low chlorinated PCDF. In the central industrial site and traffic site, OCDD is the main PCDD/Fs species in PM2.5. The metal concentrations in winter were 773.4 ± 384.1 ng/m3 for PM1.0, 2,115 ± 696 ng/m3 for PM2.5, and 12,069 ± 1,637 ng/m3 for TSP. Different metal characteristic species are observed in coarse and fine particles, with Na as the characteristic species in TSP, while K and Zn were having a higher proportion in fine particles. Water-soluble ion concentrations in winter were 5.67 ± 1.26, 7.02 ± 1.55, and 22.9 ± 3.69 μg/m3, respectively, with different composition distributions in coarse and fine particles. Cl- and Na+ were predominant in coarse particles, while nss-SO42-, NH4+, and NO3- were dominant in PM1.0 and PM2.5. A comparison between central sites revealed that NH4+ was a significant ion species in PM2.5, particularly in the industrial site, while nss-K+ concentration was notably higher in the traffic site. Using the source apportionment model PMF indicated that possible emission sources. For PM1.0, including municipal waste incinerators (MWIs) (20.0%), electric arc furnace (EAF) (25.0%), and industrial boilers (55.0%), respectively; for PM2.5, including open burning (30.0%), traffic-related (40.0%), and industrial boilers (30.0%); for TSP, including MWIs (32.0%), industrial boilers (57.0%), and traffic-related (11.0%). For PM2.5 in central industrial site, including secondary zinc smelting (35.0%), EAF (20.0%), MWIs (27.0%), and crematoriums (17.0%). The PM2.5 in central traffic site, including open burning (37.0%), MWIs (46.0%), and traffic-related (16.0%).
The RTCA experiments conducted on A549 cells indicated a trend where higher particulate mass results in lower cell viability. And oxidative potential result using Dithiothreitol assay showed that TSP had the highest OPV value, with PM1.0 roughly equivalent to PM2.5. The results for OPM indicated that the oxidative potential increases with decreasing particle size (PM1.0 > PM2.5 > TSP). There was no significant difference in OPV among different site in PM2.5, while the OPM results showed higher values for the traffic sites compared to the industrial sites. The concentrations of PM with different particle sizes were negatively correlated with OPM, indicating that OPM were primarily related to particle composition rather than mass concentration. In terms of the correlation between metal components and oxidative potential, OPV is positively correlated with Cu in different sized particles. This was mainly due to Cu being one of the species responsible for DTT oxidation-reduction reactions. Additionally, Fe, which has a higher concentration in the atmospheric environment, exhibits a moderate to high positive correlation with OPM in particles larger than 2.5 μm. Comparing the correlation between water-soluble ions and oxidative potential, the results showed that NO3- mainly contributed to the oxidative potential in fine particles (PM1.0 and PM2.5). The findings suggested that species from fine PM likely contributed more to the oxidative potential in TSP. Comparing PM2.5 in different sites, the major species contributing to PM2.5 oxidative potential in the northern industrial sites were nss-Ca2+, nss-Mg2+, and NO3-, while in the central sites (industrial and traffic sites), nss-SO42- was the main contributor.
The results revealed that the mass concentrations of PM1.0, PM2.5, and TSP in the northern industrial site range from 8.33 to 16.2 μg/m3, 21.4 to 30.3 μg/m3, and 37.5 to 96.5 μg/m3, respectively, with a PM1.0/PM2.5 ratio ranging from 0.399 to 0.526. The chemical component concentrations in different size particles were higher in winter compared to summer. The concentrations of PCDD/Fs in PM1.0, PM2.5, and TSP were 16.6 ± 12.1, 14.2 ± 10.8, and 8.34 ± 6.51 fg TEQWHO/m3, respectively in winter. The highest dioxin toxicity per gram of particles was in PM1.0 (526.3 ± 422.1 pg TEQWHO/g), followed by PM2.5 and TSP. PCDD/Fs in particle phase were mainly OCDF and 1,2,3,4,6,7,8-HpCDF with high chlorine numbers, while vapor phase predominantly contain low chlorinated PCDF. In the central industrial site and traffic site, OCDD is the main PCDD/Fs species in PM2.5. The metal concentrations in winter were 773.4 ± 384.1 ng/m3 for PM1.0, 2,115 ± 696 ng/m3 for PM2.5, and 12,069 ± 1,637 ng/m3 for TSP. Different metal characteristic species are observed in coarse and fine particles, with Na as the characteristic species in TSP, while K and Zn were having a higher proportion in fine particles. Water-soluble ion concentrations in winter were 5.67 ± 1.26, 7.02 ± 1.55, and 22.9 ± 3.69 μg/m3, respectively, with different composition distributions in coarse and fine particles. Cl- and Na+ were predominant in coarse particles, while nss-SO42-, NH4+, and NO3- were dominant in PM1.0 and PM2.5. A comparison between central sites revealed that NH4+ was a significant ion species in PM2.5, particularly in the industrial site, while nss-K+ concentration was notably higher in the traffic site. Using the source apportionment model PMF indicated that possible emission sources. For PM1.0, including municipal waste incinerators (MWIs) (20.0%), electric arc furnace (EAF) (25.0%), and industrial boilers (55.0%), respectively; for PM2.5, including open burning (30.0%), traffic-related (40.0%), and industrial boilers (30.0%); for TSP, including MWIs (32.0%), industrial boilers (57.0%), and traffic-related (11.0%). For PM2.5 in central industrial site, including secondary zinc smelting (35.0%), EAF (20.0%), MWIs (27.0%), and crematoriums (17.0%). The PM2.5 in central traffic site, including open burning (37.0%), MWIs (46.0%), and traffic-related (16.0%).
The RTCA experiments conducted on A549 cells indicated a trend where higher particulate mass results in lower cell viability. And oxidative potential result using Dithiothreitol assay showed that TSP had the highest OPV value, with PM1.0 roughly equivalent to PM2.5. The results for OPM indicated that the oxidative potential increases with decreasing particle size (PM1.0 > PM2.5 > TSP). There was no significant difference in OPV among different site in PM2.5, while the OPM results showed higher values for the traffic sites compared to the industrial sites. The concentrations of PM with different particle sizes were negatively correlated with OPM, indicating that OPM were primarily related to particle composition rather than mass concentration. In terms of the correlation between metal components and oxidative potential, OPV is positively correlated with Cu in different sized particles. This was mainly due to Cu being one of the species responsible for DTT oxidation-reduction reactions. Additionally, Fe, which has a higher concentration in the atmospheric environment, exhibits a moderate to high positive correlation with OPM in particles larger than 2.5 μm. Comparing the correlation between water-soluble ions and oxidative potential, the results showed that NO3- mainly contributed to the oxidative potential in fine particles (PM1.0 and PM2.5). The findings suggested that species from fine PM likely contributed more to the oxidative potential in TSP. Comparing PM2.5 in different sites, the major species contributing to PM2.5 oxidative potential in the northern industrial sites were nss-Ca2+, nss-Mg2+, and NO3-, while in the central sites (industrial and traffic sites), nss-SO42- was the main contributor.