侷域表面電漿子耦合螢光技術及其在生物醫學上的應用
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
周晟 | |
dc.contributor.advisor |
Chien Chou | |
dc.contributor.author |
張英風 | |
dc.contributor.author |
Ying-Feng Chang | |
dc.contributor.college |
生物醫學暨工程學院 | |
dc.contributor.committee |
||
dc.contributor.committee |
||
dc.contributor.department |
生醫光電研究所 | |
dc.contributor.studentid |
49626003 | |
dc.date.NCLavailable |
不公開 | |
dc.date.USTavailable |
2016/09/19 | |
dc.date.issued |
2011 | |
dc.date.issuedROC |
100 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
100 | |
dc.description.abstract |
當金屬奈米粒子受到入射光源激發後,會在表面產生侷域表面電漿子(localized surface plasmon),而此侷域表面電漿子產生的電磁場會被限制在一個極微小的空間區域當中,具有侷域增強的現象。本研究即利用金奈米粒子(gold nanoparticle)此一光學特性結合螢光技術,提出一種新穎且具高靈敏度的偵測方式,稱為侷域表面電漿子耦合螢光(localized surface plasmon coupled fluorescence)技術,並建立一種新型的光纖生物感測器。實驗上利用老鼠免疫球蛋白G (mouse IgG)及其抗體之間的免疫反應來驗證系統之靈敏度(∼ 1 pg/mL),並將此技術成功地運用於甲型胎兒蛋白(Alpha-fetoprotein,AFP)的檢測、乳癌的鑑別、新型流感病毒的偵測、以及SARS的診斷上。除此之外,鑒於光纖生物感測器不易量測大量之臨床檢體,故本研究亦發展出一套高通量的侷域表面電漿子耦合螢光免疫感測器,可應用於大量的臨床檢體。實驗上我們利用老鼠免疫球蛋白G測試,顯示本系統不但擁有高通量的能力同時還擁有高靈敏度(∼ 1 pg/mL)。 | |
dc.description.abstract |
In this study, based on the optical property of localized surface plasmons (LSPs) on gold nanoparticles (GNPs), we propose a GNP-based fiber-optic biosensor (FOB) which combines fluorescence detection technology with sandwich immunoassay as a localized surface plasmon coupled fluorescence fiber-optic biosensor (LSPCF-FOB), to study protein-protein interactions at ultralow concentration (pg/mL). Experimentally, the LSPCF-FOB has been demonstrated to detect mouse immunoglobulin G (IgG) at 1 pg/mL interacting with anti-mouse IgG in PBS. In addition, LSPCF-FOB is also applied for measurement of alpha-fetoprotein (AFP) in human serum and total prostate-specific antigen (t-PSA) to discriminate breast cancer in human serum, too. Moreover, the biosensor is capable of detecting SARS-CoV, and influenza A virus (S-OIV) infection. However, LSPCF-FOB is unable to show the high-throughput capability for clinical purpose. Thus, the development of high-throughput scanning immunosensor (HT-LSPCF-SI) has been designed and demonstrated. Experimentally, HT-LSPCF-SI is able to detect anti-mouse IgG interacting with mouse IgG at 1 pg/mL in concentration. This indicates that the proposed HT-LSPCF-SI not only presents high-throughput ability but also shows high detection sensitivity and high specificity to measure bio-specimens at low concentration at pg/mL level. As a result, the HT-LSPCF-SI can be anticipated to be a early diagnosis and detection tool in clinical applications. | |
dc.description.abstractopendate |
||
dc.description.degree |
博士 | |
dc.description.tableofcontents |
ContentsSignature Page iThesis Approval Form iiAcknowledgments iiiChinese Abstract ivEnglish Abstract vTable of Contents viList of Figures ixList of Tables xiiChapter 1 Introduction 1Chapter 2 Theory of local-field enhancement and fluorescence amplification 42.1 Localized surface plasmons in metallic nanoparticles…………… 42.2 Local-field enhancement of metallic nanoparticles and fluorescence amplification 7Chapter 3 Experiment 103.1 Experimental setup 103.2 Surface modification of the PMMA fiber 113.3 Fabrication of sandwich immunocomplexes 123.4 Preparation of the LSPCF probe 133.5 Optical setup of high-throughput LSPCF scanning immunosensor 143.6 Detection limit based on International Union of Pure and Applied Chemistry (IUPAC) definition 15Chapter 4 LSPCF-FOB detection limit test 164.1 Comparison of different fluorescence probes 164.2 Mouse IgG detection using LSPCF-FOB 18Chapter 5 LSPCF-FOB for alpha-fetoprotein (AFP) detection in human serum 245.1 Motivation 245.2 Reagents and Materials 255.3 Results and discussion 255.4 Conclusions 31Chapter 6 Discrimination of breast cancer by measuring prostate-specific antigen levels in women serum 326.1 Motivation 326.2 Reagents and Materials 346.3 Results and discussion 346.4 Conclusions 42Chapter 7 Detection of severe acute respiratory syndrome (SARS) coronavirus nucleocapsid protein in human serum 447.1 Motivation 447.2 Reagents and Materials 467.3 Results and discussion 477.4 Conclusions 55Chapter 8 Detection of Swine-origin Influenza A (H1N1) Viruses 578.1 Motivation 578.2 Reagents and Materials 598.3 Results and discussion 608.4 Conclusions 73Chapter 9 High-throughput scanning immunosensor based on LSPCF technique 759.1 Motivation 759.2 Reagents and Materials 759.3 Mouse IgG detection using HT-LSPCF-SI 76Chapter 10 Summary 83References 84 | |
dc.identifier.citation |
REFERENCESChapter 1.1. Chang, Y.-H.; Chang, T.-C.; Kao, E.-F.; Chou, C. “Detection of protein A produced by staphylococcus aureus with a fiber-optic-based biosensor,” Biosci. Biotech. Bioch. 1996, 60, 1571-1574.2. Taitt, C. R.; Anderson, G. P., Ligler F. S. “Evanescent wave fluorescence biosensors,” Biosens. Bioelectron. 2005, 20, 2470-2487.3. Marazuela, M. D.; Moreno-Bondi, M. C. “Fiber-optic biosensors - an overview,” Anal. Bioanal. Chem. 2002, 372, 664-682.4. Mehrvar, M.; Bis, C.; Scharer, J. M.; Moo-Young, M.; Luong, J. H. “Fiber-optic biosensors-trends and advances,” Anal. Sci. 2000, 16, 677-692.5. Wolfbeis, O. S. “Fiber-optic chemical sensors and biosensors,” Anal. Chem. 2002, 74, 2663-2678.6. Narang, U.; Anderson, G. P.; Ligler F. S.; Burans, J. “Fiber optic-based biosensor for ricin,” Biosens. Bioelectron. 1997, 12, 937-945.7. Pergande, M.; Jung, K. “Sandwich enzyme immunoassay of cystatin C in serum with commercially available antibodies,” Clin. Chem. 1993, 39, 1885-1890.8. Benkert, A.; Scheller, F.; Schossler, W. et al. “Development of a creatinine ELISA and an amperometric antibody-based creatinine sensor with a detection limit in the nanomolar range,” Anal. Chem. 2000, 72, 916-921.9. Monaci, L.; Tregoat, V.; Hengel, A. J.; Anklam, E. “Milk allergens, their characteristics and their detection in food: A review,” Eur. Food Res. Technol. 2006, 223, 149-179.10. Bellet, D. H. ; Wands, J. R. ; Isselbacher, K. J. ; Bohuon, C. “Serum alpha-fetoprotein levels in human disease: perspective from a highly specific monoclonal radioimmunoassay,” Proc. Natl. Acad. Sci. U. S. A. 1984, 81, 3869-3873.11. Stone, R. T.; Maurer, R. R. “Radioimmunoassay of porcine alpha fetoprotein,” Biol. Reprod. 1979, 20, 947-953.12. Ho, J.-A. A.; Chang, H.-C.; Shih, N.-Y. et al. “Diagnostic detection of human lung cancer-associated antigen using a gold nanoparticle-based electrochemical immunosensor,” Anal. Chem. 2010, 82, 5944-5950.13. Saxena, U.; Chakraborty, M.; Goswami, P. “Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples,” Biosens. Bioelectron. 2010, 26, 3037-3043.14. Stewart, M. E.; Anderton, C. R.; Thompson, L. B. et al. “Nanostructured plasmonic sensors,” Chem. Rev. 2008, 108, 494-521.15. Anker, J. N.; Hall, W. P.; Lyandres, O. et al. “Biosensing with plasmonic nanosensors,” Nat. Mater. 2008, 7, 442-453.16. Willets, K. A.; Van Duyne, R. P. “Localized surface plasmon resonance spectroscopy and sensing,” Annu. Rev. Phys. Chem. 2007, 58, 267-297.17. Zhao, J.; Zhang, X. Y.; Yonzon, C. R.; Haes, A. J.; Van Duyne, R. P. “Localized surface plasmon resonance biosensors,” Nanomedicine 2006, 1, 219-22818. Hsieh, B.-Y.; Chang, Y.-F.; Ng, M.-Y. et al. “Localized surface plasmon coupled fluorescence fiber-optic biosensor with gold nanoparticles,” Anal. Chem. 2007, 79, 3487-3493.19. Chang, Y.-F.; Chen, R.-C.; Lee, Y.-J. et al. “Localized surface plasmon coupled fluorescence fiber-optic biosensor for alpha-fetoprotein detection in human serum,” Biosens. Bioelectron. 2009, 24, 1610-1614.20. Chang, Y.-F.; Hung, S.-H.; Lee, Y.-J. et al. “Discrimination of breast cancer by measuring prostate-specific antigen levels in women's serum,” Anal. Chem. 2011, 83, 5324-5328.21. Huang, J.-C.; Chang, Y.-F.; Chen, K.-H. et al. “Detection of severe acute respiratory syndrome (SARS) coronavirus nucleocapsid protein in human serum using a localized surface plasmon coupled fluorescence fiber-optic biosensor,” Biosens. Bioelectron. 2009, 25, 320-325.22. Chang, Y.-F.; Wang, S.-F.; Huang, J.-C. et al. “Detection of swine-origin influenza A (H1N1) viruses using a localized surface plasmon coupled fluorescence fiber-optic biosensor,” Biosens. Bioelectron. 2010, 26, 1068-1073.Chapter 2.1. Ghosh, S. K.; Pal, T. “Interparticle coupling effect on the surface plasmon resonance of gold nanoparticles: from theory to applications,” Chem. Rev. 2007, 107, 4797-4862.2. Ng, M.-Y.; Liu, W.-C. “Fluorescence enhancements of fiber-optic biosensor with metallic nanoparticles,” Opt. Express 2009, 17, 5867-5878.3. Stewart, M. E.; Anderton, C. R.; Thompson, L. B. et al. “Nanostructured plasmonic sensors,” Chem. Rev. 2008, 108, 494-521.4. Rycenga, M.; Cobley, C. M.; Zeng, J. et al. “Controlling the synthesis and assembly of silver nanostructures for plasmonic applications,” Chem. Rev. 2011, 111, 3669-3712.5. Hartland, G. V. “Optical studies of dynamics in noble metal nanostructures,” Chem. Rev. 2011, 111, 3858-3887.6. Jones, M. R.; Osberg, K. D.; Macfarlane, R. J.; Langille, M. R. and Mirkin, C. A. “Templated techniques for the synthesis and assembly of plasmonic nanostructures,” Chem. Rev. 2011, 111, 3736-3827.7. Mayer, K. M. and Hafner, J. H. “Localized surface plasmon resonance sensors,” Chem. Rev. 2011, 111, 3828-3857.8. Anker, J. N.; Hall, W. P.; Lyandres, O. et al. “Biosensing with plasmonic nanosensors,” Nat. Mater. 2008, 7, 442-453.9. Willets, K. A.; Van Duyne, R. P. “Localized surface plasmon resonance spectroscopy and sensing,” Annu. Rev. Phys. Chem. 2007, 58, 267-297.10. Zhao, J.; Zhang, X. Y.; Yonzon, C. R.; Haes, A. J.; Van Duyne, R. P. “Localized surface plasmon resonance biosensors,” Nanomedicine 2006, 1, 219-228.11. Bohren, C. F.; Huffman, D. R.: Absorption and Scattering of Light by SmallParticles, Wiley, New York, 1983.12. Kreibig, U.; Vollmer, M.: Optical Properties of Metal Clusters, Springer, Berlin, 1995.13. Geddes, C. D.: Metal-Enhanced Fluorescence Wiley, New York, 2010.14. Weitz, D. A.; Garoff, S.; Gersten, J. I.; Nitzan, A. “The enhancement of Raman scattering, resonance Raman scattering, and fluorescence from molecules adsorbed on a rough silver surface,” J. Chem. Phys. 1983, 78, 5324-5338.15. Dulkeith, E.; Morteani, A. C.; Niedereichholz, T. et al. “Fluorescence quenching of dye molecules near gold nanoparticles: radiative and nonradiative effects,” Phys. Rev. Lett. 2002, 89, 203002.16. Chance, R. R.; Prock, A.; Silbey, R. “Molecular fluorescence and energy transfer near interfaces,” Adv. Chem. Phys. 1978, 37, 1-65.17. Baffou, G.; Girard, C.; Dujardin, E.; des Francs, G. C.; Martin, O. J. F. “Molecular quenching and relaxation in a plasmonic tunable system,” Phys. Rev. B 2008, 77, 121101.18. Stoller, P.; Jacobsen, V.; Sandoghdar, V. “Measurement of the complex dielectric constant of a single gold nanoparticle,” Opt. lett. 2006, 31, 2474-2476.19. Chien, F.-C.; Chen, S.-J. “Direct determination of the refractive index and thickness of a biolayer based on coupled waveguide-surface plasmon resonance mode,” Opt. lett. 2006, 31, 187-189.20. Roth, J. “The preparation of protein A-gold complexes with 3 nm and 15 nm gold particles and their use in labelling multiple antigens on ultra-thin sections,” Histochemical J. 1982, 14, 791-801.Chapter 3.1. Fu, C., 2009 / 07. The master thesis of department of chemistry, National Tsing Hua University, Hsinchu, Taiwan.2. Thomsen, V.; Schatzlein, D.; Mercuro, D. “Limits of detection in spectroscopy,” Spectroscopy 2003, 18, 112-114.Chapter 4.1. Sugunan, A.; Thanachayanont, C.; Dutta, J.; Hilborn, J. G. “Heavy-metal ion sensors using chitosan-capped gold nanoparticles,” Sci. Technol. Adv. Mater. 2005, 6, 335-340.2. Chhabra, R.; Sharma, J.; Wang, H. et al. “Distance-dependent interactions between gold nanoparticles and fluorescent molecules with DNA as tunable spacers,” Nanotechnology 2009, 20, 485201.3. Cheng, S. F.; Chau, L. K. “Colloidal gold-modified optical fiber for chemical and biochemical sensing,” Anal. Chem. 2003, 75, 16-21.4. Malinsky, M. D.; Kelly, K. L.; Schatz, G. C.; Van Duyne, R. P. “Chain length dependence and sensing capabilities of the localized surface plasmon resonance of silver nanoparticles chemically modified with alkanethiol self-assembled monolayers,” J. Am. Chem. Soc. 2001, 123, 1471-1482.5. Anderson, G. P.; Jacoby, M. A.; Ligler, F. S.; King, K. D. “Effectiveness of protein A for antibody immobilization for a fiber optic biosensor,” Biosens. Bioelectron. 1997, 12, 329-336.6. Hong, B.; Kang, K. A. “Biocompatible, nanogold-particle fluorescence enhancer for fluorophore mediated, optical immunosensor,” Biosens. Bioelectron. 2006, 21, 1333-1338.7. Borejdo, J.; Gryczynski, Z.; Calander, N.; Muthu, P.; Gryczynski, I. “Application of surface plasmon coupled emission to study of muscle,” Biophys. J. 2006, 91, 2626-2635.Chapter 5.1. Fu, Z. F.; Hao, C.; Fei, X. G.; Ju, H. X. J. “Flow-injection chemiluminescent immunoassay for α-fetoprotein based on epoxysilane modified glass microbeads,” Immunol. Methods 2006, 312, 61-67.2. Tsai, W. C.; Lin. I. C. “Development of a piezoelectric immunosensor for the detection of alpha-fetoprotein,” Sens. Actuator B-Chem. 2005, 106, 455-460.3. Xu, Y. Y.; Bian, C.; Chen, S. F.; Xia, S. H. “A microelectronic technology based amperometric immunosensor for α-fetoprotein using mixed self-assembled monolayers and gold nanoparticles,” Anal. Chim. Acta 2006, 561, 48-54.4. Zhu, Q.; Ruo, Y.; Yaqin, C. et al. “A new potentiometric immunosensor for determination of α-fetoprotein based on improved gelatin–silver complex film,” Electrochim. Acta 2006, 51, 3763-3768.5. Chou, S. F.; Hsu, W. L.; Hwang, J. M.; Chen, C. Y. “Determination of α-fetoprotein in human serum by a quartz crystal microbalance-based immunosensor,” Clin. Chem. 2002, 48, 913-918.6. Zhang, B. ; Zhang, X. ; Yan, H. H. et al. “A novel multi-array immunoassay device for tumor markers based on insert-plug model of piezoelectric immunosensor,” Biosens. Bioelectron. 2007, 23, 19-25.7. Ao, L. M.; Gao, F.; Pan, B. F.; He, R.; Cui, D. X. “Fluoroimmunoassay for antigen based on fluorescence quenching signal of gold nanoparticles,” Anal. Chem. 2006, 78, 1104-1106.8. Ye, Z.; Tan, M.; Wang, G.; Yuan, J. “Development of functionalized terbium fluorescent nanoparticles for antibody labeling and time-resolved fluoroimmunoassay application,” Talanta 2005, 65, 206-210.9. Master, S. R.; Bierl, C.; Kricka, L. J. “Diagnostic challenges for multiplexed protein microarrays,” Drug Discov. Today 2006, 11, 1007-1011.10. Weiss, H. S.; Stemmer, S. M.; Liberzon, E. et al. “Quantitation of alpha-fetoprotein messenger RNA for early detection of recurrent hepatocellular carcinoma: A prospective pilot study,” Cancer Detect. Prev. 2006, 30, 204-209.11. Stoeva, S. I.; Lee, J. S.; Smith, J. E.; Rosen, S. T.; Mirkin, C. A. “Multiplexed detection of protein cancer markers with biobarcoded nanoparticle probes,” J. Am. Chem. Soc. 2006, 128, 8378-8379.12. Lin, J. H.; Ju, H. X. “Electrochemical and chemiluminescent immunosensors for tumor markers,” Biosens. Bioelectron. 2005, 20, 1461-1470.13. Cheng, S. F.; Chau, L. K. “Colloidal gold-modified optical fiber for chemical and biochemical sensing,” Anal. Chem. 2003, 75, 16-21.14. Malinsky, M. D.; Kelly, K. L.; Schatz, G. C.; Van Duyne, R. P. “Chain length dependence and sensing capabilities of the localized surface plasmon resonance of silver nanoparticles chemically modified with alkanethiol self-assembled monolayers,” J. Am. Chem. Soc. 2001, 123, 1471-1482.15. Yu, F.; Persson, B.; Lőfås, S; Knoll, W. “Surface plasmon fluorescence immunoassay of free prostate-specific antigen in human plasma at the femtomolar level,” Anal. Chem. 2004, 76, 6765-6770.16. Kingsmore, S. F. “Multiplexed protein measurement: technologies and applications of protein and antibody arrays,” Nat. Rev. Drug Discov. 2006, 5, 310-320.Chapter 6.1. Mbeunkui, F.; Metge, B. J.; Shevde, L. A.; Pannell, L. K. “Identification of differentially secreted biomarkers using LC-MS/MS in isogenic cell lines representing a progression of breast cancer,” J. Proteome Res. 2007, 6, 2993-3002.2. Dua, R. S.; Isacke, C. M.; Gui, G. P. H. “The intraductal approach to breast cancer biomarker discovery,” J. Clin. Oncol. 2006, 24, 1209-1216.3. Ciatto, S.; Rosselli, D. T. M.; Zappa, M. “The detectability of breast cancer by screening mammography,” Br. J. Cancer 1995, 71, 337-339.4. Esserman, L.; Cowley, H.; Eberle, C. et al. “Improving the accuracy of mammography: volume and outcome relationships,” J. Natl. Cancer Inst. 2002, 94, 369-375.5. Bernstein, J. L.; Godbold, J. H.; Raptis, G. et al. “Identification of mammaglobin as a novel serum marker for breast cancer,” Clin. Cancer Res. 2005, 11, 6528-6535.6. Panini, N. V.; Messina, G. A.; Salinas, E.; Fernandez, H.; Raba, J. “Integrated microfluidic systems with an immunosensor modified with carbon nanotubes for detection of prostate specific antigen (PSA) in human serum samples,” Biosens. Bioelectron. 2008, 23, 1145-1151.7. Narita, D.; Raica M.; Suciu C.; Cîmpean, A.; Anghel A. “Immunohistochemical expression of androgen receptor and prostate-specific antigen in breast cancer,” Folia Histochem. Cytobiol. 2006, 44, 165-172.8. Diamandis, E. P.; Yu, H.; Sutherland, D. J. A. “Detection of prostate-specific antigen immunoreactivity in breast tumors,” Breast Cancer Res. Treat. 1994, 32, 301-310.9. Monne, M.; Croce, C. M.; Yu, H.; Diamandis, E. P. “Molecular characterization of prostate-specific antigen messenger RNA expressed in breast tumors,” Cancer Res. 1994, 54, 6344-6347.10. Yu, H.; Levesque, M. A.; Clark, G. M.; Diamandis, E. P. “Prognostic value of prostate-specific antigen for women with breast cancer: a large United States cohort study,” Clin. Cancer Res. 1998, 4, 1489-1497.11. Carder, P. J.; Speirs, V.; Ramsdale, J.; Lansdown, M. R. J. “Expression of prostate specific antigen in male breast cancer,” J. Clin. Pathol. 2005, 58 (1), 69-71.12. Sauter, E. R.; Lininger, J.; Magklara, A.; Hewett, J. E.; Diamandis, E. P. “Association of kallikrein expression in nipple aspirate fluid with breast cancer risk,” Int. J. Cancer 2004, 108, 588-591.13. Sauter, E. R.; Tichansky, D. S.; Chervoneva, I.; Diamandis, E. P. “Circulating testosterone and prostate-specific antigen in nipple aspirate fluid and tissue are associated with breast cancer,” Environ. Health Perspect. 2002, 110, 241-246.14. Sauter, E. R.; Chervoneva, I.; Diamandis, A. et al. “Prostate-specific antigen and insulin-like growth factor binding protein-3 in nipple aspirate fluid are associated with breast cancer,” Cancer Detect. Prev. 2002, 26, 149-157.15. Sauter, E. R.; Klein, G.; Wagner-Mann, C.; Diamandis, E. P. “Prostate-specific antigen expression in nipple aspirate fluid is associated with advanced breast cancer,” Cancer Detect. Prev. 2004, 28, 27-31.16. Radowicki, S.; Kunicki, M.; Bandurska-Stankiewicz, E. “Prostate-specific antigen in the serum of women with benign breast disease,” Eur. J. Obstet. Gynecol. Reprod. Biol. 2008, 138, 212-216.17. Black, M. H.; Giai, M.; Ponzone, R. et al. “Serum total and free prostate-specific antigen for breast cancer diagnosis in women,” Clin. Cancer Res. 2000, 6, 467-473.18. Narita, D.; Anghel, A.; Motoc, M. “Prostate-specific antigen may serve as a pathological predictor in breast cancer,” Rom. J. Morphol. Embryol. 2008, 49, 173-180.19. Yang, Q. F.; Nakamura, M.; Nakamura, Y. et al. “Correlation of prostate-specific antigen promoter polymorphisms with clinicopathological characteristics in breast cancer,” Anticancer Res. 2002, 22, 1825-1828.20. Yang, Q. F.; Sakurai, T.; Shan, L. et al. “Novel polymorphisms of prostate-specific antigen (PSA) gene associated with PSA mRNA expression in breast cancer,” J. Hum. Genet 2000, 45, 363-366.21. Miller, M. K.; Unger, P. D.; Bleiweiss, I. J. “Immunohistochemical analysis of prostate specific antigen in breast cancer,” Breast Cancer Res. Treat. 2001, 68, 111-116.22. Ho, J.-A. A.; Chang, H.-C.; Shih, N.-Y. et al. “Diagnostic detection of human lung cancer-associated antigen using a gold nanoparticle-based electrochemical immunosensor,” Anal. Chem. 2010, 82, 5944-5950.23. de la Escosura-Muniz A.; Sanchez-Espinel, C.; Diaz-Freitas, B. et al. “Rapid identification and quantification of tumor cells using an electrocatalytic method based on gold nanoparticles,” Anal. Chem. 2009, 8, 10268-10274.24. Saxena, U.; Chakraborty, M.; Goswami, P. “Covalent immobilization of cholesterol oxidase on self-assembled gold nanoparticles for highly sensitive amperometric detection of cholesterol in real samples,” Biosens. Bioelectron. 2010, 26, 3037-3043.25. Sartippour, M. R.; Zhang, L.; Lu, M.; Wang, H.-J.; Brooks, M. N. “Nipple fluid basic fibroblast growth factor in patients with breast cancer,” Cancer Epidemiol. Biomarkers Prev. 2005, 14, 2995-2998.26. Harman, S. M.; Gucciardo, F.; Heward, C. B. et al. “Discrimination of breast cancer by anti-malignin antibody serum test in women undergoing biopsy,” Cancer Epidemiol. Biomarkers Prev. 2005, 14, 2310-2315.27. Gann, P. H.; Hennekens, C. H.; Stampfer, M. J. “A prospective evaluation of plasma prostate-specific antigen for detection of prostatic cancer,” J. Am. Med. Assoc. 1995, 273, 289-294.28. Catalona, W. J.; Smith, D. S.; Ratliff, T. L. et al. “Measurement of prostate-specific antigen in serum as a screening test for prostate cancer,” N. Engl. J. Med. 1991, 324, 1156-1161.29. Elmore, J. G.; Armstrong, K.; Lehman, C. D.; Fletcher, S. W. “Screening for breast cancer,” J. Am. Med. Assoc. 2005, 293, 1245-1256.30. Borchert, G. H.; Melegos, D. N.; Tomlinson, G. et al. “Molecular forms of prostate-specific antigen in the serum of women with benign and malignant breast diseases,” Br. J. Cancer 1997, 76, 1087-1094.Chapter 7.1. Drosten, C.; Doerr, H. W.; Lim, W. ; Stohr, K.; Matthias, N. “SARS molecular detection external quality assurance,” Emerg. Infect. Dis. 2004, 10, 2200-2203.2. Fouchier, R. A. M.; Kuiken, T.; Schutten, M. et al. “Aetiology: Koch's postulates fulfilled for SARS virus,” Nature 2003, 423, 240-240.3. Wang, W. K.; Chen, S. Y.; Liu, I. J. et al. “Detection of SARS-associated coronavirus in throat wash and saliva in early diagnosis,” Emerg. Infect. Dis. 2004, 10, 1213-1219.4. Jiang, S. S. ; Chen, T. C. ; Yang, J. Y. et al. “Sensitive and quantitative detection of severe acute respiratory syndrome coronavirus infection by real-tme nested polymerase chain reaction,” Clin. Infect. Dis. 2004, 38, 293-296.5. Che, X. Y.; Qiu, L. W.; Pan, Y. X. et al. “Sensitive and specific monoclonal antibody-based capture enzyme immunoassay for detection of nucleocapsid antigen in sera from patients with severe acute respiratory syndrome,” J. Clin. Microbiol. 2004, 42, 2629-2635.6. Marra, M. A.; Jones, S. J. M.; Astell, C. R. et al. “The genome sequence of the SARS-associated coronavirus,” Science 2003, 300, 1399-1404.7. Rota, P. A.; Oberste, M. S.; Monroe, S. S. et al. “Characterization of a novel coronavirus associated with severe acute respiratory syndrome,” Science 2003, 300, 1394-1399.8. Hourfar, M. K.; Roth, W. K.; Seifried, E. ; Schmidt, M. “Comparison of two real-time quantitative assays for detection of devere scute respiratory syndrome coronavirus,” J. Clin. Microbiol. 2004, 42, 2094-2100.9. Louie, L.; Simor, A. E.; Chong, S. et al. “Detection of severe acute respiratory syndrome coronavirus in stool specimens by commercially available real-time reverse transcriptase PCR Assays,” J. Clin. Microbiol. 2006, 44, 4193-4196.10. Petrich, A.; Mahony, J.; Chong, S. et al. “Multicenter comparison of nucleic acid extraction methods for detection of severe acute respiratory syndrome coronavirus RNA in stool specimens,” J. Clin. Microbiol. 2006, 44, 2681-2688.11. Yam, W. C.; Chan, K. H.; Poon, L. L. M. et al. “Evaluation of reverse transcription-PCR assays for rapid diagnosis of severe acute respiratory syndrome associated with a novel coronavirus,” J. Clin. Microbiol. 2003, 41, 4521-4524.12. Li, Y. H.; Li, J. Liu, X. E. et al. “Detection of the nucleocapsid protein of severe acute respiratory syndrome coronavirus in serum: Comparison with results of other viral markers,” J. Virol. Methods 2005, 130, 45-50.13. Liu, I. J.; Chen, P. J.; Yeh, S. H. et al. “Immunofluorescence assay for detection of the nucleocapsid antigen of the severe acute respiratory syndrome (SARS)-associated coronavirus in cells derived from throat wash samples of patients with SARS,” J. Clin. Microbiol. 2005, 43, 2444-2448.14. Fujimoto, K.; Chan, K. H.; Takeda, K. et al. “Sensitive and specific enzyme-linked immunosorbent assay using chemiluminescence for detection of severe acute respiratory syndrome viral infection,” J. Clin. Microbiol. 2008, 46, 302-310.15. Poon, L. L. M.; Wong, B. W. Y.; Chan, K. H. et al. “Evaluation of real-time reverse transcriptase PCR and real-time loop-mediated amplification assays for severe acute respiratory syndrome coronavirus detection,” J. Clin. Microbiol. 2005, 43, 3457-3459.16. Hong, T. C. T.; Mai, Q. L.; Cuong, D. V. et al. “Development and evaluation of a novel loop-mediated isothermal amplification method for rapid detection of severe acute respiratory syndrome coronavirus,” J. Clin. Microbiol. 2004, 42, 1956-1961.17. Poon, L. L. M.; Leung, C. S. W.; Tashiro, M. et al. “Rapid detection of the severe acute respiratory syndrome (SARS) coronavirus by a loop-mediated isothermal amplification assay,” Clin. Chem. 2004, 50, 1050-1052.18. Abad-Valle, P.; Fernandez-Abedul, M. T.; Costa-Garcia, A. “Genosensor on gold films with enzymatic electrochemical detection of a SARS virus sequence,” Biosens. Bioelectron. 2005, 20, 2251-2260.19. Wang, B.; Potter, S. J.; Lin, Y. et al. “Rapid and sensitive detection of severe acute respiratory syndrome coronavirus by rolling circle amplification,” J. Clin. Microbiol. 2005, 43, 2339-2344.20. Shi, Y.; Yi, Y.; Li, P. et al. “Diagnosis of severe acute respiratory syndrome (SARS) by detection of SARS coronavirus nucleocapsid antibodies in an antigen-capturing enzyme-linked immunosorbent assay,” J. Clin. Microbiol. 2003, 41, 5781-5782.21. Peiris, J. S. M.; Lai, S. T.; Poon, L. L. M. et al. “Coronavirus as a possible cause of severe acute respiratory syndrome,” Lancet 2003, 361, 1319-1325.22. Peiris, J. S. M.; Chu, C. M.; Cheng, V. C. C. et al. “Clinical progression and viral load in a community outbreak of coronavirus-associated SARS pneumonia: a prospective study,” Lancet 2003, 361, 1767-1772.23. Zhao, J.; Wang, W.; Wang, G. F. et al. “Development and evaluation of an enzyme-linked immunosorbent assay for detection of antibodies against the spike protein of SARS-coronavirus,” J. Clin. Virol. 2005, 33, 12-18.24. Haynes, L. M.; Miao, C.; Harcourt, J. L. et al. “Recombinant protein-based assays for detection of antibodies to severe acute respiratory syndrome coronavirus spike and nucleocapsid proteins,” Clin. Vaccine Immunol. 2007, 14, 331-333.25. Manopo, I.; Lu, L. Q.; He, Q. G. et al. “Evaluation of a safe and sensitive Spike protein-based immunofluorescence assay for the detection of antibody responses to SARS-CoV,” J. Immunol. Methods 2005, 296, 37-44.26. Chen, S.; Lu, D.; Zhang, M. et al. “Double-antigen sandwich ELISA for detection of antibodies to SARS-associated coronavirus in human serum,” Eur. J. Clin. Microbiol. Infect. Dis. 2005, 24, 549-553.27. Chan, P. K. S.; Liu, E. Y. M.; Leung, D. T. M. et al. “Evaluation of a recombinant nucleocapsid protein-based assay for Anti-SARS-CoV IgG detection,” J. Med. Virol. 2005, 75, 181-184.28. Qiu, M.; Wang, J.; Wang, H. et al. “Use of the COOH portion of the nucleocapsid protein in an antigen-capturing enzyme-linked immunosorbent assay for specific and sensitive detection of severe acute respiratory syndrome coronavirus,” Clin. Diagn. Lab. Immunol. 2005, 12, 474-476.29. He, Q. G.; Du, Q. Y.; Lau, S. L. et al. “Characterization of monoclonal antibody against SARS coronavirus nucleocapsid antigen and development of an antigen capture ELISA,” J. Virol. Methods 2005, 127, 46-53.30. Lau, S. K. P.; Woo, P. C. Y.; Wong, B. H. L. et al. “Detection of severe acute respiratory syndrome (SARS) coronavirus nucleocapsid protein in SARS patients by enzyme-linked immunosorbent assay,” J. Clin. Microbiol. 2004, 42, 2884-2889.31. Shang, B.; Wang, X.-Y.; Yuan, J.-W. et al. “Characterization and application of monoclonal antibodies against N protein of SARS-coronavirus,” Biochem. Biophys. Res. Commun. 2005, 336, 110-117.Chapter 8.1. Garten, R. J.; Davis, C. T.; Russel, C. A. et al. “Antigenic and genetic characteristics of swine-origin 2009 A(H1N1) influenza viruses circulating in humans,” Science 2009, 325, 197-201.2. Lu, Q.; Zhang, X.-Q.; Pond, S. L. K. et al. “Detection in 2009 of the swine origin influenza A (H1N1) virus by a subtyping microarray,” J. Clin. Microbiol. 2009, 47, 3060-3061.3. Smith, G. J. D.; Vijaykrishna, D.; Bahl, J. et al. “Origins and evolutionary genomics of the 2009 swine-origin H1N1 influenza A epidemic,” Nature 2009, 459, 1122-1125.4. Naffakh, N.; van der Werf, S. “April 2009: an outbreak of swine-origin influenza A (H1N1) virus with evidence for human-to-human transmission,” Microbes Infect. 2009, 11, 725-728.5. Brown, I. H. “The epidemiology and evolution of influenza viruses in pigs,” Vet. Microbiol. 2000, 74, 29-46.6. Van Reeth, K. “Avian and swine influenza viruses: our current understanding of the zoonotic risk,” Vet. Res. 2007, 38, 243-260.7. Fraser, C.; Donnelly, C. A.; Cauchemez, S. et al. “Pandemic potential of a strain of influenza A (H1N1): early findings,” Science 2009, 324, 1557-1561.8. Lau, J. T. F.; Griffiths, S.; Choi, K. C.; Tsui, H. Y. “Widespread public misconception in the early phase of the H1N1 influenza epidemic,” J. Infect. 2009, 59, 122-127.9. Munster, V. J.; de Wit, E.; van den Brand, J. M. A. et al. “Pathogenesis and transmission of swine-origin 2009 A (H1N1) influenza virus in ferrets,” Science 2009, 325, 481-483.10. Maines, T. R.; Jayaraman, A.; Belser, J. A. et al. “Transmission and pathogenesis of swine-origin 2009 A(H1N1) influenza viruses in ferrets and mice,” Science 2009, 325, 484-487.11. van der Vries, E.; Jonges, M.; Herfst, S. et al. “Evaluation of a rapid molecular algorithm for detection of pandemic influenza A (H1N1) 2009 virus and screening for a key oseltamivir resistance (H275Y) substitution in neuraminidase,” J. Clin. Virol. 2010, 47, 34-37.12. Rungrotmongkol, T.; Intharathep, P.; Malaisree, M. et al. “Susceptibility of antiviral drugs against 2009 influenza A (H1N1) virus,” Biochem. Biophys. Res. Commun. 2009, 385, 390-394.13. Beigel, J. H.; Farrar, J.; Han, A. M. et al. “Avian influenza A (H5N1) infection in humans,” N. Engl. J. Med. 2005, 353, 1374-1385.14. He, Q.; Velumani, S.; Du, Q. et al. “Detection of H5 avian influenza viruses by antigen-capture enzyme-linked immunosorbent assay using H5-specific monoclonal antibody,” Clin. Vaccine Immunol. 2007, 14, 617-623.15. Thomsen, V.; Schatzlein, D.; Mercuro, D. “Limits of detection in spectroscopy,” Spectroscopy 2003, 18, 112-114.16. Bose, M. E.; Beck, E. T.; Ledeboer, N. et al., 2009. J. Clin. Microbiol. 47, 2779-2786.17. He, J.; Bose, M. E.; Beck, E. T. et al. “Rapid multiplex reverse transcription-PCR typing of influenza A and B virus, and subtyping of influenza A virus into H1, 2, 3, 5, 7, 9, N1 (Human), N1 (Animal), N2, and N7, including typing of novel swine origin influenza A (H1N1) virus, during the 2009 outbreak in Milwaukee, Wisconsin,” J. Clin. Microbiol. 2009, 47, 2772-2778.18. Guo, L.; Garten, R. J.; Foust, A. S. et al. “Rapid identification of oseltamivir-resistant influenza A(H1N1) viruses with H274Y mutation by RT-PCR/restriction fragment length polymorphism assay,” Antiviral Res. 2009, 82, 29-33.19. Chan, K. H.; Lai, S. T.; Poon, L. L. M. et al. “Analytical sensitivity of rapid influenza antigen detection tests for swine-origin influenza virus (H1N1),” J. Clin. Virol. 2009, 45, 205-207.20. Wenzel, J. J.; Walch, H.; Bollwein, M. et al. “Library of prefabricated locked nucleic acid hydrolysis probes facilitates rapid development of reverse-transcription quantitative real-time PCR assays for detection of novel influenza A/H1N1/09 virus,” Clin. Chem. 2009, 55, 2218-2222.21. Yang, J.-R.; Lo, J.; Liu, J.-L. et al. “Rapid SYBR green I and modified probe real-time reverse transcription-PCR assays identify influenza H1N1 viruses and distinguish between pandemic and seasonal strains,” J. Clin. Microbiol. 2009, 47, 3714-3716.22. Cunha, B. A.; Thekkel, V.; Cohan, C. “Nosocomial swine influenza (H1N1) pneumonia: lessons learned from an illustrative case” Infect. Control Hosp. Epidemiol. 2009, 31, 102-104.23. Taylor, J.; McPhie, K.; Druce, J. et al. “Evaluation of twenty rapid antigen tests for the detection of human influenza A H5N1, H3N2, H1N1, and B viruses,” J. Med. Virol. 2009, 81, 1918-1922.24. Balish, A.; Warnes, C. M.; Wu, K. et al. “Evaluation of rapid influenza diagnostic tests for detection of novel influenza A (H1N1) virus-United States, 2009,” JAMA-J. Am. Med. Assoc. 2009, 302, 1163-1164.25. Drexler, J. F.; Helmer, A.; Kirberg, H. et al. “Poor clinical sensitivity of rapid antigen test for influenza A pandemic (H1N1) 2009 virus,” Emerg. Infect. Dis 2009, 15, 1662-1664.26. Faix, D. J.; Sherman, S. S.; Waterman, S. H. “Rapid-test sensitivity for novel swine-origin influenza A (H1N1) virus in humans,” N. Engl. J. Med. 2009, 361, 728-729.27. Sabetta, J. R.; Smardin, J.; Burns, L. et al. “Performance of rapid influenza diagnostic tests during two school outbreaks of 2009 pandemic influenza A (H1N1) virus infection-connecticut, 2009,” JAMA-J. Am. Med. Assoc. 2009, 302, 1962-1964.28. Vasoo, S.; Stevens, J. and Singh, K. “Rapid antigen tests for diagnosis of pandemic (swine) influenza A/H1N1,” Clin. Infect. Dis. 2009, 49, 1090-1093.Chapter 9.1. Sakanyan, V. “High-throughput and multiplexed protein array technology: protein–DNA and protein–protein interactions,” J. Chromatogr. B 2005, 815, 77-95. | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/51139 | |
dc.language.iso |
英文 | |
dc.relation.alma |
991002624509706772 | |
dc.relation.page |
105 | |
dc.subject.keyword |
侷域表面電漿子 | |
dc.subject.keyword |
光纖感測(知)器 | |
dc.subject.keyword |
奈米金屬粒子 | |
dc.subject.keyword |
Localized surface plasmon coupled fluorescence | |
dc.subject.keyword |
fiber-optic biosensor | |
dc.subject.keyword |
metallic nanoparticles | |
dc.title |
侷域表面電漿子耦合螢光技術及其在生物醫學上的應用 | zh-TW |
dc.title |
Localized surface plasmon coupled fluorescence technique and its biomedical applications | en |
dc.type |
Thesis | zh-TW |
檔案
全文未公開。
所屬典藏: 生醫光電研究所