近端脛骨平台上幾何外形、骨截面特徵與對應手術操作對當代單髁膝關節置換之影響
顯示簡易詮釋資料 統計資料| 欄位 | 內容 | 語言 |
|---|---|---|
dc.contributor.advisor |
鄭誠功 | |
dc.contributor.advisor |
Cheng-Kung Cheng | |
dc.contributor.author |
張宗維 | |
dc.contributor.author |
Tsung-Wei Chang | |
dc.contributor.college |
生物醫學暨工程學院 | |
dc.contributor.committee |
||
dc.contributor.committee |
||
dc.contributor.department |
生物醫學工程學系 | |
dc.contributor.studentid |
39304031 | |
dc.date.NCLavailable |
2012/11/02 | |
dc.date.USTavailable |
2012/11/02 | |
dc.date.issued |
2011 | |
dc.date.issuedROC |
100 | |
dc.date.paperavailable |
立即公開 | |
dc.date.schoolyear |
100 | |
dc.description.abstract |
單髁膝關節置換為近代治療單側脛股骨關節疾病的有效手術方式之一。近年來單髁膝關節置換於十年內的存活率通常可達到九成以上。不過術後的存活率往往會因為脛骨元件幾何外形與手術操作等不同因素而有產生差異。導致單髁膝關節置換失敗進而必須施行再置換手術的原因,絕大部分為脛骨元件沉陷、持續性疼痛或是近端脛骨平台骨折所引起。臨床上發現脛骨元件與骨截面上的覆蓋率不佳,或是手術操作不當與骨截面轉角外形導致應變增加及骨質退化是造成術後失敗的主因。因此,本研究將分析國人內/外側近端脛骨平台幾何外形,並與不同單髁膝關節元件置換系統比較其尺寸與特徽;另一方面,希望藉由改良骨截面上轉角幾何外形以降低應變值,並利用有限元素法模擬評估與材料試驗機進行模型驗證。本研究結果也將提供臨床醫師在針對罹患單側脛股骨關節退化性關節炎的患者進行單髁膝關節置換手術前挑選脛骨元件及手術操作的參考。 在量測結果中發現內/外側近端脛骨平台外形上有顯著的不同。對外側脛骨平台而言,其外形屬於前後對稱型;但對內側脛骨平台而言,其內外徑最寬的位置則較偏後側處。此外,與市售不同單髁膝關節置換系統全尺寸比對後,發現大多數的脛骨元件有過大的ML尺寸分佈。同時,國人的脛骨平台縱橫比會隨著ML尺寸的增加而逐漸減少,但反觀市售元件設計多屬於固定值。另一方面,利用有限元素模擬骨截面外形研究中,在模擬骨截面上發生垂直過切模型中,骨截面上應變值會比標準模型增加約50 %;而在改良圓角式骨截面外形模型中,其應變值則降低約40 %。此外,相較於完整脛骨模型中,模擬脛骨元件植入後的模型在脛骨平台下方均有40 %的應變增加,但彼此間卻沒顯著地差異。 本研究建議在施行單髁膝關節置換時,應該考慮內/外側近端脛骨平台外形的不同而分別選用。甚至部位特定化的設計更有助於提高脛骨元件與骨截面上的覆蓋率。透過本研究量測資料,將可以提供不同脛骨元件設計已因應不同人種上解剖與適用性的差異。同時從有限元素結果中證實,在單髁膝關節置換後近端脛骨平台像是一似懸臂樑結構。而當發生手術失誤時會降低脛骨平台的支撐力外,更會增加近端脛骨元件周邊骨折發生的可能性。此外,改良圓角式外形替代過去直角式外形設計,能有效地緩和骨截面上應變值,進而可被預期有助於避免術後持續性疼痛或是骨質退化的發生。再者,於改良後的手術流程中,利用預鑽骨隧道的優勢將可以精準地完成所需的後傾角外,也可以藉此避免發生不必要的過切現象。 | |
dc.description.abstract |
Unicompartmental knee arthroplasty(UKA)is a well-established surgical procedure with failure rates averaging 10% at ten years post-surgery. A revision arthroplasty is often performed after an inadequate primary UKA. Tibial baseplate subsidence, persistent pain and periprosthetic fracture of the proximal tibia are the predominant indicators for revision. Optimizing coverage of the resected tibial surface is an important consideration in UKA, and surgical errors and acute corners on the resected surface can place excessive strains on the bone, leading to bone degeneration. The purpose of this study was to analyze the morphology of the medial and lateral tibial plateau of Chinese knees and to compare measurements and features with the plateau dimensions of different commercial unicondylar tibial baseplates. Additionally, we attempted to lower strains by altering the orthogonal geometry of resected surface and avoiding extended vertical saw cuts. Finite element models were utilized to predict biomechanical behavior and were subsequently compared against in vitro experimental data. We anticipate that the results could provide guidelines for surgeons in selecting a tibial baseplate and surgical technique for patients with isolated medial or lateral tibiofemoral osteoarthritis prior to UKA. The results showed significant differences between the shapes of the medial and lateral tibial plateaus for the patients analyzed. For the lateral tibial plateau, the shape was symmetric about the mediolateral (ML) axis. The medial plateaus presented their widest ML width in an obviously more posterior position than the lateral compartment. Moreover, the results showed that the majority of the commercial baseplates studied tended to display overhang for all measured mediolateral dimensions. Additionally, the plateau aspect ratio decreased with increasing mediolateral dimensions, in contrast to the constant aspect ratio shown by conventional UKA prostheses. On the other hand, on the resected surface of the extended saw cut model, the greatest strains showed a 50% increase over a standard implant; conversely, the strains decreased by 40% for the radial-corner shaped model. For all UKA models, the peak strains below the resection level increased by 40% relative to an intact tibia. There was no significant difference amongst the implanted models. Our study suggests using UKA prostheses that take into account the morphological differences between the medial and lateral tibial compartments. Compartment-specific designs may optimize coverage between the prosthesis and resected tibial surface. The morphometrical measurements presented can allow manufacturers to design UKA baseplates that accommodate the structural variability for different ethnic groups. The finite element models demonstrated that a large increase in strains arises on the tibial plateau to resist a cantilever-like bending moment following UKA. Surgical errors generally weaken the tibial support and increase the risk of fractures. This study provides guidance on altering the orthogonal geometry into a radial-shape to reduce strains and avoid degenerative remodeling. Furthermore, it could be expected that predrilling a posteriorly sloped tunnel through the tibia prior to cutting could achieve greater accuracy in surgical preparations. | |
dc.description.abstractopendate |
||
dc.description.degree |
博士 | |
dc.description.tableofcontents |
中文摘要 IAbstract III目錄 V圖目錄 VIII表目錄 XI第一章.前言 1 1-1 膝關節的組成與構造 3 1-2 膝關節的活動與運動學 6 1-3 膝關節的病變與處理方式 91-4 單髁人工膝關節置換概述 111-4.1 單髁人工膝關節置換系統之發展 13 1-4.2 單髁膝關節置換適應症與系統之分類 16 1-4.3 單髁人工膝關節置換系統分類比較 181-4.4 臨床文獻回顧 20 1-5 單髁膝關節置換之臨床問題 231-5.1單髁膝關節脛骨元件之不良覆蓋率 251-5.2 單髁膝關節置換術後持續性疼痛 271-5.3 單髁膝關節置換後初期脛骨元件周圍骨折 291-6 文獻總結與研究動機 331-7 研究目的 35第二章.材料與方法 36 2-1 近端脛骨平台幾何形態分析及元件設計研究 36 2-1.1 膝關節三維實體模型建立 38 2-1.2 單髁人工膝關節元件切骨模擬 412-1.3 骨截面解剖參數量測 442-1.4 市售單髁膝關節脛骨元件適用性比較 45 2-2 改良骨截面外形與對應手術操作於單腂膝關節置換分析 472-2.1 單髁膝關節實體模型之建立 482-2.2 骨截面及手術流程模擬 512-2.3 有限元素模型之分析 522-2.4 體外生物力學測試 552-2.5 有限元素結果與實驗模型驗証 58第三章.結果 593-1 近端脛骨平台幾何形態分析及元件設計研究 593-1.1 內/外側脛骨平台量測參數 613-1.2 量測結果與脛骨元件尺寸分析 672-2 改良骨截面外形與對應手術操作於單腂膝關節置換分析 693-2.1 圓角式骨截面外形曲率之評估 693-2.2不同轉角幾何外形對於骨截面應變分佈之影響 713-2.3 有限元素模型驗證 753-2.4 改良骨截面幾何及手術流程模擬 77第四章.討論 784-1 近端脛骨幾何形態分析及元件設計研究 784-1.1 研究方法 794-1.2 內/外側脛骨平台量測參數與文獻比較 804-1.3 內/外側脛骨平台量測參數分析 824-1.4 市售單髁膝關節脛骨元件適用性比較 854-1.5 未來研究方向 874-2 改良骨截面外形與對應手術操作於單腂膝關節置換分析 884-2.1 模型基本假設及研究限制 884-2.2 材料試驗機測試結果 904-2.3 有限元素模型驗證 914-2.4 單髁膝關節置換力學之討論 934-2.5 骨截面垂直過切之討論 954-2.6 現有單髁膝關節置換器械之討論 964-2.7 改良骨截面幾何外形與對應手術操作流程之討論 984-2.8 未來研究方向 100第五章 結論 101參考文獻 102 | |
dc.identifier.citation |
1. Bartholomew M: The skeletal system. In Bartholomew M (ed): Essentials of anatomy & physiology. Prentice-Hall; 20002. Scott WN: The Knee. Mosby, St. Louis, 19943. Norkin CC. and Levangie PK. Joint structure and function: a comprehensive analysis. Philadelphia: F.A. Davis Company, 19924. Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clinical Orthopaedics and Related Research. 290: 259, 19935. Andriacchi TP, Stanwyck TS, Galante JO. Knee biomechanics and total knee replacement. Journal of Arthroplasty. 1(3): 211, 19866. Nordin M, Frankel VH: Biomechanics of knee. In Nordin M, Frankel VH (eds): Basic biomechanics of the musculoskeletal system. Lippincott Williams & Wilkins; 20017. Insall JN, Binazzi R, Soudry M, Mestriner LA. Total Knee Arthroplasty. Clin Orthop Relat Res. 192: 13, 19588. Buechel FF, Pappas MJ. New Jersey low contact stress knee replacement system. Ten-year evaluation of meniscal bearings. Orthop Clin North Am. 20(2): 147, 19899. 許萬宜;台灣髖膝兩全人工關節成形手術年度統計報告(1992.7.1~1993.6.31) J. Orth Surg ROC.; 10: 289, 199310. Muller W: The knee: Form, function and ligament reconstruction, Springer-Verleg, New York, 198311. Tanavalee, A. and Yuktanandana, P.: Unicondylar knee arthroplasty: an overview. The Thai Journal of Orthopaedic Surgery. 28(1): 1, 200312. Laurencin CT, Zelicof SB, Scott RD, Ewald FC: Unicompartmental versus total knee arthroplasty in the same patient: a comparative study. Clin Orthop Relat Res. 273: 151, 199113. Murray DW, Goodfellow JW, O’Connor JJ. The Oxford medial unicompartmental arthroplasty: a ten-year survival study. J Bone Joint Surg Br. 80(6): 983, 199814. Squire MW, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC.: Unicompartmental knee replacement. A minimum 15 year followup study. Clin Orthop Relat Res. 367: 61, 199915. Berger RA, Nedeff DD, Barden RM, Sheinkop MM, Jacobs JJ, Rosenberg AG, Galante JO. Unicompartmental knee arthroplasty. Clinical experience at 6- to 10-year followup. Clin Orthop Relat Res. 367: 50, 199916. McKeever D. Tibial Plateau Prosthesis. Clin Orthop Relat Res. 18: 86, 196017. MacIntosh D. Hemiarthroplasty of the Knee using a Space Occupying Prosthesis for Painful Varus and Valgus Deformities. In Proceedings of the Joint Meeting of the Orthopaedic Associations of the English-Speaking World. J Bone Joint Surg Am. 40: 1431, 195818. Gunston FH. Polycentric knee arthroplasty: prosthetic simulation of normal knee movement. J Bone Joint Surg [Br] 53: 272, 197119. Marmor L. The modular knee. Clin Orthop 94: 242, 197320. Scott RD, Cobb AG, McQueary FG, Thornhill TS. Unicompartmental knee arthroplasty: eight- to 12-year follow-up evaluation with survivorship analysis. Clin Orthop. 271: 96, 199121. Goodfellow JW, O’Connor JJ. Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis. Clin Orthop Relat Res. 205: 21, 198622. Goodfellow JW, O’Connor JJ. The mechanics of the knee and prosthesis design. J Bone Joint Surg [Br]. 60(3): 358, 197823. Repicci JA, Eberle RW. Minimally invasive surgical technique for unicondylar knee arthroplasty. J South Orthop Assoc. 8: 20, 199924. Kozinn SC, Scott R. Unicondylar knee arthroplasty. J Bone Joint Surg [Am]. 71:145, 198925. Gleeson RE, Evans R, Ackroyd, CE, Webb J, Newman JH. Fixed or mobile bearing unicompartmental knee replacement?A comparative cohort study. Knee 11: 379, 200426. Robertsson O, Knutson K, Lewold S, Lidgren L. The routine of surgical management reduces failure after unicompartmental knee arthroplasty. J Bone Joint Surg [Br]. 83: 45, 200127. Ashraf T, Newman JH, Desai VV, Beard D, Nevelos JE. Polyethylene wear in a non-congruous unicompartmental knee replacement a retrieval analysis. Knee 11: 177, 200428. Psychoyios V, Crawford R, O’Connor JJ, Murray DW. Wear of congruent meniscal bearings in unicompartmental knee arthroplasty. A retrieval study of 16 specimens. J Bone Joint Surg [Br]. 80: 976, 199829. Huang CH, Ma HM, Fo HY, Liau JJ, Cheng CK. Osteolysis in failed total knee arthroplasty- a comparison between the mobile bearing and fixed bearing knees, J Bone Joint Surg [Am]. 84: 2224, 200230. Marmor L. The modular knee. Clin Orthop. 94: 242, 197331. Insall J, Walker P. Unicondylar knee replacement. Clin Orthop. 120: 83, 197632. Laskin RS: Unicompartmental tibiofemoral resurfacing arthroplasty. J Bone Joint Surg [Am]. 60: 182, 197833. McAuley JP, Engh GA, Ammeen D. Revision of failed unicompartmental knee arthroplasty. Clin Orthop. 392:279, 200134. Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultrahigh molecular weight components for total joint replacement. J Bone Joint Surg [Am]. 68:1041, 198635. Barrett WP, Scott RD. Revision of failed unicondylar unicompartmental knee arthroplasty. J Bone Joint Surg [Am]. 69: 1328, 198736. Scott RD, Cobb AG, McQueary FG, Thornhill TS. Unicompartmental knee arthroplasty: eight to 12-year follow-up evaluation with survivorship analysis. Clin Orth. 271: 96, 199137. Goodfellow JW, Kershaw CJ, D’a Benson K, O’Connor JJ. The Oxford knee for unicompartmental osteoarthritis. J Bone Joint Surg [Br]. 70:692-701, 198838. Vardi G, Strover AE. Early complications of unicompartmental knee replacement: the Droitwich experience. Knee. 11: 389, 200439. Australian Orthopaedic Association National Joint Replacement Registry. Annual report. Adelaide: AOA; 200840. The Swedish knee arthroplasty register. Annual report, 200841. Riddle DL, Jiranek WA, McGlynn FJ. Yearly incidence of unicompartmental knee arthroplasty in the United States. J Arthroplast. 23(3):408, 200842. Squire MW, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Unicompartmental knee replacement: a minimum 15 year follow-up study. Clin. Orthop. 367: 61, 199943. Insall JN: Revision of aseptic failed total knee arthroplasty. p. 935. In Insall JN, Windsor RE, Scott WN, Kelly MA, Aglietti P (eds): Surgery of the Knee. Churchill Livingstone; New York, 199444. Krackow KA: Prosthesis selection. p. 49. In Krackow, K.A. (eds): The Technique of Total Knee Arthroplasty. Mosby; St. Louis, 199145. Freeman MAR, Todd RC, Bamert P, Day WH: ICLH arthroplasty of the knee: 1968 - 1977. Journal of Bone and Joint Surgery (British) 60(3):339, 197846. Chau R, Gulati A, Pandit H, Beard DJ, Price AJ, Dodd CA, Gill HS, Murray DW. Tibial component overhang following unicompartmental knee replacement--does it matter? Knee. 16(5):310, 200947. Cheng CK, Lung CY, Lee YM, Huang CH: A new approach of designing the tibial baseplate of total knee prostheses. Clinical Biomechanics. 14(2):112, 199948. Surendran S, Kwak DS, Lee UY, Park SE, Gopinathan P, Han SH, Han CW. Anthropometry of the medial tibial condyle to design the tibial component for unicondylar knee arthroplasty for the Korean population. Knee Surg Sports Traumatol Arthrosc. 15(4): 436, 200749. Kwak DS, Surendran S, Pengatteeri YH, Park SE, Choi KN, Gopinathan P, Han SH, Han CW. Morphometry of the proximal tibia to design the tibial component of total knee arthroplasty for the Korean population. Knee. 14(4): 295, 200750. Servien E, Saffarini M, Lustig S, Chomel S, Neyret P. Lateral versus medial tibial plateau: morphometric analysis and adaptability with current tibial component design. Knee Surg Sports Traumatol Arthrosc. 16(12): 1141, 200851. Pattin CA, Caler WE, Carter DR.Cyclic mechanical property degradation during fatigue loading of cortical bone. J Biomech. 29(1): 69, 199652. Simpson DJ, Price AJ, Gulati A, Murray DW, Gill HS. Elevated proximal tibial strains following unicompartmental knee replacement--a possible cause of pain. Med Eng Phys. 31(7): 752, 200953. Iesaka K, Tsumura H, Sonoda H, Sawatari T, Takasita M, Torisu T. The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty. Journal of Biomechanics. 35: 962, 200254. Sawatari T, Tsumura H, Iesaka K, Furushiro Y, Torisu T. Three-dimensional finite element analysis of unicompartmental knee arthroplasty–the influence of tibial component inclination. J Orthop. 23: 549, 200555. Clarius M, Haas D, Aldinger PR, Jaeger S, Jakubowitz E, Seeger JB. Periprosthetic tibial fractures in unicompartmental knee arthroplasty as a function of extended sagittal saw cuts: An experimental study. Knee. 17(1): 57, 201056. Rudol G, Jackson MP, James SE. Medial tibial plateau fracture complicating unicompartmental knee arthroplasty. J Arthroplasty. 22(1):148, 200757. Kumar A, Chambers I, Wong P. Periprosthetic fracture of the proximal tibia after lateral unicompartmental knee arthroplasty. J Arthroplasty. 23(4): 615, 200858. Berger RA,Meneghini RM, Jacobs JJ, SheinkopMB, Della Valle CJ, Rosenberg AG, et al. Results of unicompartmental knee arthroplasty at aminimumof ten years of follow-up. J Bone Jt Surg [Am]. 87(5): 999, 200559. The Norwegian arthroplasty register. Annual report, 201060. Clarius M, Aldinger PR, Bruckner T, Seeger JB. Saw cuts in unicompartmental knee arthroplasty: An analysis of sawbone preparations. Knee. 16(5): 314, 200961. Uehara K, Kadoya Y, Kobayashi A, Ohashi H, Yamano Y Anthropometry of the proximal tibia to design a total knee prosthesis for the Japanese population. J Arthroplasty. 17(8): 1028, 200262. Kellis E. Tibiofemoral joint forces during maximal isokinetic eccentric and concentric efforts of the knee flexors. Clin Biomech. 16(3): 229, 200163. Taylor M, Tanner KE, Freeman MA. Finite element analysis of the implanted proximal tibia: a relationship between the initial cancellous bone stresses and implant migration. J Biomech. 31(4): 303, 199864. Hsu RW, Himeno S, Coventry MB, Chao EY. Normal axial alignment of the lower extremity and load-bearing distribution at the knee. Clin Orthop Relat Res. (255):215, 199065. www.sawbones.com66. Lewis G. Properties of acrylic bone cement: state of the art review. J Biomed Mater Res. 38(2):155, 199767. Orr JF, Dunne NJ, Quinn JC. Shrinkage stresses in bone cement. Biomaterials. 24(17): 2933, 200368. Cheal EJ, Hayes WC, Lee CH, Snyder BD, Miller J. Stress analysis of a condylar knee tibial component: influence of metaphyseal shell properties and cement injection depth. J Orthop Res. 3(4): 424, 198569. Cheng FB, Ji XF, Zheng WX, Lai Y, Cheng KL, Feng JC, Li YQ. Use of anthropometric data from the medial tibial and femoral condyles to design unicondylar knee prostheses in the Chinese population. Knee Surg Sports Traumatol Arthrosc. 18(3): 352, 201070. Hodge WA, Harman MK, Banks SA. Patterns of knee osteoarthritis in Arabian and American knees. J. Arthroplasty. 24(3): 448, 200971. Pennington DW, Swienckowski JJ, Lutes WB, Drake GN. Lateral unicompartmental knee arthroplasty: survivorship and technical considerations at an average follow-up of 12.4 years. J Arthroplasty. 21(1):13, 200672. Sah AP, Scott RD. Lateral unicompartmental knee arthroplasty through a medial approach. Study with an average five-year follow-up. J Bone Joint Surg Am. 89(9): 1948, 200773. Emerson RH, Martinez JM. Men versus women: does size matter in total knee arthroplasty? Clin Orthop Relat Res. 466: 2706, 200874. Ritter MA, Wing JT, Berend ME, Davis KE, Meding JB. The clinical effect of gender on outcome of total knee arthroplasty. J Arthroplasty. 23:331, 200875. Ashraf T, Newman JH, Evans RL, Ackroyd CE. Lateral unicompartmental knee replacement survivorship and clinical experience over 21 years. J Bone Joint Surg Br. 84(8): 1126, 200276. Stulberg BN, Dombrowski RM, Froimson M, Easley K. Computed tomography analysis of proximal tibial coverage. Clin Orthop Relat Res. 311: 148, 199577. Wevers HW, Simurda M, Griffin M, Tarrel J. Improved fit by asymmetric tibial prosthesis for total knee arthroplasty. Med Eng Phys. 16: 297, 199478. Heiner AD. Structural properties of fourth-generation composite femurs and tibias. J Biomech. 41(15): 3282, 200879. Chong AC, Miller F, Buxton M, Friis EA. Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone. J Biomech Eng. 129(4):487, 200780. Chong AC, Friis EA, Ballard GP, Czuwala PJ, Cooke FW. Fatigue performance of composite analogue femur constructs under high activity loading. Ann Biomed Eng. 35(7): 1196, 200781. Huang CH, Liau JJ, Huang CH, Cheng CK. Influence of post-cam design on stresses on posterior-stabilized tibial posts. Clin Orthop Relat Res. 450:150, 200682. Huang CH, Liau JJ, Huang CH, Cheng CK. Stress analysis of the anterior tibial post in posterior stabilized knee prostheses. J Orthop Res 25(4): 442, 200783. Completo A, Fonseca F, Simoes JA. Finite element and experimental cortex strains of the intact and implanted tibia. J Biomech Eng. 129(5): 791, 200784. Gray HA, Taddei F, Zavatsky AB, Cristofolini L, Gill HS. Experimental validation of a finite element model of a human cadaveric tibia. J Biomech Eng. 130(3): 031016, 200885. Gray HA, Zavatsky AB, Taddei F, Cristofolini L, Gill HS. Experimental validation of a finite element model of a composite tibia. Proc Inst Mech Eng H. 221(3): 315, 200786. Taddei F, Cristofolini L, Martelli S, Gill HS, Viceconti M. Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy. J Biomech. 39(13): 2457, 200687. Waide V, Cristofolini L, Stolk J, Verdonschot N, Boogaard GJ, Toni A. Modelling the fibrous tissue layer in cemented hip replacements: experimental and finite element methods. J Biomech. 37(1):13, 200488. Stolk J, Verdonschot N, Cristofolini L, Toni A, Huiskes R. Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests. J Biomech. 35(4):49, 200289. Lengsfeld M, Schmitt J, Alter P, Kaminsky J, Leppek R. Comparison of geometry-based and CT voxel-based finite element modelling and experimental validation. Med Eng Phys. 20(7): 515, 199890. Kennedy WR, White RP. Unicompartmental arthroplasty of the knee: postoperative alignment and its influence on overall results. Clin Orthop 221: 278, 198791. Taylor M, Tanner KE. Fatigue failure of cancellous bone: a possible cause of implanted migration and loosening. J Bone Joint Surg Br. 79(2): 181, 1997 | |
dc.identifier.uri |
https://hdl.handle.net/20.500.14371/51165 | |
dc.language.iso |
中文 | |
dc.relation.alma |
991002647099706772 | |
dc.relation.page |
110 | |
dc.subject.keyword |
單髁膝關節置換 | |
dc.subject.keyword |
內/外側脛骨平台 | |
dc.subject.keyword |
幾何外形量測 | |
dc.subject.keyword |
有限元素法 | |
dc.subject.keyword |
應變分佈 | |
dc.subject.keyword |
Unicompartmental knee arthroplasty | |
dc.subject.keyword |
Medial and lateral tibial plateau | |
dc.subject.keyword |
Morphometrical measurement | |
dc.subject.keyword |
Finite element analysis | |
dc.subject.keyword |
Strain distribution | |
dc.title |
近端脛骨平台上幾何外形、骨截面特徵與對應手術操作對當代單髁膝關節置換之影響 | zh-TW |
dc.title |
The Effect of Proximal Tibial Plateau Geometries and the Resected Surface with Corresponding Surgical Technique Following Modern Unicompartmental Knee Arthroplasty | en |
dc.type |
Thesis | zh-TW |
檔案
- 5219901.pdf (2.94 MB, Adobe PDF)
所屬典藏: 生物醫學工程學系