豬眼睛水晶體前緣囊袋之彈性係數

Elastic Constant of Porcine Anterior Lens Capsule

檔案

全文未公開。

日期

2012

類型

語言

中文

摘要

實驗目的: 本實驗室為了要了解水晶體在做調適時在力學上的特性,而使用拉力試驗的方法來測量豬眼睛水晶體前緣囊袋的彈性係數。
實驗方法: 選取屠宰後12小時之內的豬眼睛作實驗,在清除眼睛角膜、虹膜後,取出水晶體前緣囊袋,浸泡於0.1% trypsin和0.02% EDTA的37 °C混和溶液中,清除水晶體上皮細胞。使用掃描式電子顯微鏡測量30個囊袋樣本的厚度,利用可以移動旋轉和傾斜的特殊載台,從一個樣本中找出多個可以觀察厚度的觀察處,每個觀察處再利用系統從螢幕中拉出直線,測量囊袋樣本的厚度。再來利用拉伸試驗的方法,使用通過生物相容性測試的瞬間膠,固定15個囊袋樣本於自行設計的拉伸夾具上,模擬眼球中環境,在37 °C的磷酸鹽緩衝溶液中進行拉伸試驗。
實驗結果: 水晶體前緣囊袋經過0.1% trypsin & 0.02% EDTA 處理後,可將水晶體囊袋上皮細胞清除。而水晶體前緣囊袋厚度經過統計後,厚度值為20.70 ± 4.36 μm。而拉伸結果曲線呈兩段曲線,前段平坦部分和後段陡峭部分。線性擬合前段平坦曲線,得彈性係數為0.035 ± 0.018 N/mm2。線性擬合後段陡峭部分,得彈性係數為0.242 ± 0.019 N/mm2。使用自然指數擬合後段陡峭部分曲線,計算彈性係數,當拉伸應變量為17.5% 時為0.238 ± 0.043 N/mm2。當拉伸應變量為20% 時為0.247 ± 0.074 N/mm2。當拉伸應變量為22.5% 時為0.255 ± 0.073 N/mm2。
實驗結論: 本實驗使用掃描式電子顯微鏡測量水晶體囊袋厚度,再經由比例尺的觀察可以得知拉伸樣本時的截面積。再利用通過生物性相容測試的瞬間膠來固定囊袋樣本,進行拉伸試驗,可以獲得囊袋樣本的兩段彈性係數。藉此了解眼睛在作調適時的力學特性,得知豬眼睛與人眼睛調適時的對照比較。
Purpose: The purpose of this study was to obtain the elastic constants of the porcine anterior lens capsule for further research associated with accommodation.
Methods: The material comprised 30 anterior lens capsules from pig post-mortem. After removing the cornea and iris, the porcine anterior lens capsule was dissected. The lens epithelial cells were removed by soaking in the 0.1% trypsin and 0.02% EDTA for 5 minutes. Capsular thickness was measured under scanning electron microscope by rotating and tilting the special sample platform. For elastic properties test, the anterior lens capsules were fixed on the two fixtures by instant adhesive glue which connected to tensile test machine and load cell, respectively, and stretched with constant speed until the force reached to 0.46 N. The sample size n = 15.
Results: The average capsular thickness was 20.70 ± 4.36 μm. The curves of the tensile test demonstrated toe-segment part and steep part. Elastic constant were obtained by linearly and non-linearly fitting curves with 0.035 ± 0.018 N/mm2 and 0.242 ± 0.019 N/mm2 for toe-segment part and steep part respectively. Elastic constant at the strain level of 17.5%, 20% and 22.5% was 0.238 ± 0.043 N/mm2, 0.247 ± 0.074 N/mm2, and 0.255 ± 0.073 N/mm2 that fitted exponentially.
Conclusion: The thickness of the porcine anterior-lens capsule can be examined by scanning electron microscope. The cross-sectional area of a sample was estimated by observing the stretched sample. The elastic constant of toe-segment part and steep part were obtained by tensile test. In which the two ends of sample was glued on the clamping apparatuses which were mounted on the MTS machine. The results showed the mechanical characteristics of the lens capsule used for accommodation. These data can be used for comparison with humans.
顯示完整詮釋資料 統計資料

引用此條目

曾子洋 (2012). 豬眼睛水晶體前緣囊袋之彈性係數. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/51691

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/51691