鋯鈦酸鉛高頻超音波探針製作及臨床驗證

Development of the Lead Zirconate Titanate (PZT) High Frequency Ultrasound Needle Transducer and Clinical Verification

檔案

日期

2013

類型

語言

中文

摘要

現今硬脊膜外腔麻醉手術進行時,必須依賴醫師的經驗將外套針穿刺到硬脊膜外腔中並注入麻藥,但隨著病患年紀、體型以及受傷等關係,脊椎結構改變影響醫師已熟悉穿刺的路徑,因此穿刺時仍有風險,為了避免刺穿硬脊膜(Dural Puncture, DP),我們利用高頻超音波嵌入式探針偵測黃韌帶及硬脊膜與硬脊膜外套針的相對位置,在黃韌帶前觀測到訊號,可提供預知訊號避免刺穿硬脊膜,提升手術成功機率。
本研究選用鋯鈦酸鉛(PZT-5H)為超音波探針之壓電晶體,本晶體有容易生產、應用技術成熟等優點,具有於研究室完成開發的特性。本研究開發之探針規格為:中心頻率為30 MHz,壓電晶體尺寸為0.5×0.5 mm2。外部規格:外徑為1 mm,長度為14 cm的超音波探針進行麻醉輔助。製作完成後量測探針的中心頻率約為27.4 MHz ~ 36 MHz,-6 dB頻寬為14% ~ 59.1%,探針規格可應用於輔助麻醉手術使用。
臨床動物實驗中,使用自製超音波探針取代穿刺內針進行硬脊膜外腔穿刺,由接收組織反射A-mode訊號辨別探針尖端位置,目前於穿刺實驗中已多次量測硬脊膜訊號。
本研究提供完整的設計、製作與封裝鋯鈦酸鉛超音波探針過程,並以動物實驗證其在硬脊膜外腔穿刺定位的可行性。更進一步研究以期提供應用於人體其它的穿刺定位手術使用。
Epidural anesthesia is a highly experience dependent procedure. It is a challenge to properly position the epidural needle into the epidural space without dural puncture which damages the dura maters. Avoiding dural puncture, we develop a ultrasound needle transducer epidural positioning system.
We use lead zirconate titanate (PZT-5H) as active piezoelectric crystal, which is the most mature material in fabricating ultrasound transducer in Taiwan. In this study, a high-frequency single-element needle transducer with an aperture size of 0.5×0.5 mm2, needle length is 14 cm, and the center frequency is 30 MHz. After fabrication the measured -6 dB center frequency and bandwidth were 27.4 MHz ~ 36 MHz and 14% ~ 59.1%.
In clinical animal experiments acquired the A-mode signals by needle ultrasound transducer. Than use these signals to identify the needle’s position inside the body. At present, we’ve successfully measured the signals of Dura Mater.
In this study we provide the design and fabrication’s procedure of lead zirconate titanate high frequency ultrasound transducer. We’ve successfully verification that the ultrasound transducer is able to identify the position of epidural space. In the future, we will try to use this system in other surgery’s position.
顯示完整詮釋資料 統計資料

引用此條目

謝巧羚 (2013). 鋯鈦酸鉛高頻超音波探針製作及臨床驗證. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/54524

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/54524