在今日的牙醫治療裡,以固定式贗復物進行口腔重建,是最被常使用的方式之一。但是,當需要為患者製作多顆支台齒的固定牙橋時,要一次達到完整而精密的取模並不容易;尤其在下顎雙側都有支台齒時,更為困難。本研究擬提出一個新式的多階段取模法,試圖透過以低稠度印模材,先行對各顆支台齒進行分段印模,最後再以高稠度印模材將已聚合的低稠度印模,做一次性的取出,期望透過這樣的取模方式,能同時克服唾液控制與印模工作時間限制的臨床難題,以達到下顎多顆支台齒牙橋的精準取模。
本研究選用三種常用的印模材料進行測試,分別為兩種加成式矽化物(Aquasil與Express XT)以及一種聚乙醚(Impregum)。研究分成兩個部分,第一部份探討唾液污染以及後續的清水清潔,是否會影響新式多階段取模法中,低稠度印模材與高稠度印模材間的鍵結強度,並與傳統的一階段印模法作比較。第二部份則是驗證此新式多階段取模法的空間準確性。首先製作一個具有四顆支台齒的標準金屬模型,以模擬下顎的犬齒與第一大臼齒。分別使用三種印模材對金屬模型進行印模,一組為低稠度印模材受到人工唾液污染;另一組為低稠度印模材受到人工唾液污染後,以三用噴槍清水沖洗並吹乾後,再使用高稠度印模材取出;而傳統的一階段印模法為控制組。每組取15個印模並製成硬石膏模型。然後,以工具顯微鏡測量各支台齒上參考點間的距離,並比較不同組別之間石膏模型三度空間準確性的差異。各組之抗張強度與模型上參考點間的距離,分別以二維變異數與Tukey多重比較分析(α = 0.05).
實驗結果顯示,人工唾液污染會降低三種材料的低稠度印模材與高稠度印模材間間的抗張強度,Express XT在唾液污染後加以清潔,則可恢復與控制組相當的抗張強度;而Aquasil與Impregum兩種印模材,在唾液污染加以清潔後,其低稠度與高稠度印模材間的鍵結強度,則只有部份恢復。在三度空間準確性的實驗結果顯示,Express XT印模材所產生的石膏模型,其支台齒上參考點間的距離,在各組間均無統計上的差異。而Aquasil與Impregum彈性印模材,在多階式印模法與一階式印模法的模型,也無明顯差異,只有一組參考點間距雖有統計上差異,但實際的差距可能沒有臨床意義。本研究初步證實新式的多階段取模法具有臨床應用的潛力。
Fixed prostheses for full mouth reconstruction are widely used in modern dentistry. However, making impressions for a long-span bridge with multiple abutments, especially in the lower arch, sometimes are quite difficult. To overcome this clinical problem, we proposed a novel multiple stage impression technique, which is through sectional impression of abutments with wash material and then pick-up of all sections with putty material at one time. We hypothesized that the multiple-stage impression technique could provide better saliva control and sufficient working time for each single abutment, and thus have potential to make precise impression for long-span bridges with multiple abutments in lower arch.
Three commonly used impression materials including two additional silicones (Express XT and Aquasil) and one polyether (Impregum) were employed. The first part of the study was to explore the influence of saliva contamination and subsequent water cleansing on the bond strength between light-body and heavy-body of each impression materials in multiple-stage impression technique, and compare to that in conventional one-stage impression technique. The second part was to verify the dimensional accuracy of the multiple-stage impression technique. A metal cast with 4 abutments mimicking canines and first molars in the lower arch was fabricated. Impressions were made by the multiple-stage impression technique with saliva contamination between light-body and heavy-body for each impression material. Another group of the multiple-stage impression technique was also saliva contaminated but with further water cleansing andspray drying before heavy-body pickup. The impressions from the one-stage technique were served as controls. Fifteen impressions of each material for each group were made and poured with die stone. The distances between abutments of each stone cast were measured with a stereomicroscope. The measurements of tensile bond strength and dimensional accuracy of three impression materials employed in different techniques were analyzed using a 2-way ANOVA followed by Tukey’s test at α = 0.05.
The result showed that saliva contamination significantly decreased the tensile bond strength between light-body and heavy-body materials. While subsequent cleansing and drying could fully recover the bond strength for Express XT, but only partially recover for Aquasil and Impregum. In dimensional accuracy test, die stone casts retrieved from Express XT impressions did not show significant difference among three techniques. Similar results were found with Aquasil and Impregum, except that one line segment between reference points on the casts revealed statistical but insubstantial difference. In conclusion, the proposed multiple-stage impression technique demonstrates potential for clinical use.