摘要

鋯基(Zr-based)塊狀金屬玻璃(bulk metallic glass, BMG)較目前生醫用金屬材具優異的耐蝕性、較高的降伏強度及較低的彈性係數,故近年來逐漸被考慮應用到生醫用植入材。然而,在模擬生理環境溶液中BMG易有孔蝕(pitting corrosion)現象發生,導致金屬離子釋出,進而可能對生物組織有負面影響。因此,本研究在不改變BMG材料內部非結晶(amorphous)特性,同時能有效提升耐蝕性(特別是抗孔蝕能力)與生物反應的前提下,選用氮電漿浸沒離子植入(nitrogen plasma immersion ion implantation, N-PIII)技術於不含Ni的Zr62.5Cu22.5Fe5Al10 BMG表面製備出緻密的奈米厚度氮化層,並評估此氮化層對材料表面特性、耐蝕性與生物反應的影響。實驗結果顯示,BMG經N-PIII改質後(N-BMG)表面主要包含二氧化鋯和氮化鋯,表層氮離子濃度主要集中於10 nm深度,且晶相結構、表面形貌、表面潤濕性及表面粗糙度均無明顯差異。在耐蝕性部分,N-BMG之含氮化物的氧化層,顯著提升BMG孔蝕電位及腐蝕電位,並降低腐蝕速率。在血液反應部分,N-BMG比BMG具較多血小板貼附數目和較高血小板活化表現。在細胞反應部分,BMG和N-BMG均無細胞毒性,且初期人類間葉骨髓幹細胞貼附與細胞分化程度相當,但在N-BMG表面可觀察到具較快的細胞增生。本研究所選用不含Ni的Zr62.5Cu22.5Fe5Al10 BMG經N-PIII表面改質後,可有效提升其耐蝕性、血液反應和細胞反應,具有被應用為生醫植入材之潛力。
Zirconium (Zr)-based bulk metallic glass (BMG) has been considered to be potential biomaterial in recent years because of its better corrosion resistance, higher yield strength and relatively lower elastic modulus comparing to current biomedical alloys. However, BMG is prone to pitting corrosion while it contacts with simulated physiological solution. This leads to the release of metallic ions from BMG, which may cause biological side effects.
In this study, in order to increase the corrosion resistance, especially pitting corrosion resistance, of BMG without changing its bulk crystalline, nitrogen plasma immersion ion implantation (N-PIII) was used to form a protective nitride film with nanoscale thickness on the nickel-free Zr62.5Cu22.5Fe5Al10 BMG. The surface properties, corrosion resistance and biological responses of the Ni-free Zr62.5Cu22.5Fe5Al10 BMG treated with N-PIII were investigated.
Results showed that the surface of BMG after N-PIII treatment (N-BMG) mainly contained ZrO2 and ZrN; the N atoms mainly concentrated under a depth of approximately 10 nm. There was no significant difference in crystal structure, surface topography, surface wettability and surface roughness between BMG and N-BMG. As for the corrosion resistance, the presence of a protective nitride-oxide film on BMG surface led to higher pitting potential and corrosion potential and lower corrosion rate. As for the blood responses, N-BMG showed higher platelet adhesion number and better platelet activation than BMG. As for the cell responses, BMG and N-BMG were non-cytotoxic and had no difference in adhesion and differentiation of human bone marrow mesenchymal stem cells; however, N-BMG showed higher cell proliferation. According to the abovementioned results, we would conclude that N-PIII treatment enhances the corrosion resistance, blood responses and cell responses of Ni-free Zr62.5Cu22.5Fe5Al10 BMG. This fact favors the potential applications of N-BMG as biomedical implants.