Second harmonic generation (SHG), a label free imaging technique, which arises from non-centrosymmetric structures and the SH intensity depends on the relative orientation between the polarization of the incoming light and the second-order hyperpolarizability of the sample. Going beyond intensity measurements, SHG polarimetry can provide an interesting modality to probe the absolute molecular structure orientation and disorder in organized organic media, impurities in crystal structures, characteristics of surfaces and optical interfaces. Recently, SHG polarization anisotropy has been successfully applied to investigate the molecular orientation and the degree of organization in fibrotic collagen, human dermis, keloid, cornea, microtubules as well as myosin of the skeletal muscle.
Polarization analysis of SH signal can be carried out using either Jones calculus or Stokes algebra. In most applications cross-polarized two-channel detection is employed and hence use of Jones calculus is used. Strictly, the Jones method is however, only applicable for perfectly polarized light beams and is thus unsuitable in many scenarios. For example, use of cross-polarized two-channel detection does not allow the relative ratio of the polarized and un-polarized components of the field to be determined. Additionally, the full polarization state of the polarized component cannot be found due to an ambiguity over the phase difference between the two measured polarization basis vectors. In contrast, the full polarization state of a general optical signal, including partially polarized or unpolarized fields, can be characterized using Stokes algebra.
Accordingly, we developed a four-channel photon counting based Stokes-polarimeter for spatial characterization of polarization effects in second harmonic generation (SHG). We have implemented a calibration technique allowing quantitative measurement of polarization parameters, such as the degree of polarization (DOP), degree of linear polarization (DOLP), degree of circular polarization (DOCP), as well as anisotropy from the acquired Stokes parameters. The technique is used as contrast mechanism to characterize the polarization properties from two potassium dihydrogen phosphate (KDP) micro-crystals and collagen type-I in SHG microscopy. The measurements are further extended by varying the polarization states of the incident light and recording the resulting Stokes parameters of the SH signal. In turn this allows the molecular structure and orientation of the samples to be determined. Use of Stokes polarimetry is critical in determination of the full polarization state of light, and enables discrimination of material properties not possible with conventional crossed-polarized detection schemes. The combination of SHG microscopy and Stokes polarimeter hence makes a unique and powerful tool to investigate the structural order of targeted specimens. Hence, Stokes vector based SH polarimetry imaging, including a variation of the incident polarization states, provide a selective and specific contrast technique for many anisotropic molecular structures. Furthermore, we believe that photon counting detectors have the advantages of (1) better signal-to-noise ratio by avoiding 1/f noise, (2) better quantification of light intensity, and (3) allowing background fluorescence to be gated. The temporal resolution afforded can also be very useful in fluorescence studies.

所屬典藏

生醫光電研究所
顯示完整詮釋資料 統計資料

引用此條目

Nirmal Mazumder (2013). Revealing molecular structure with multiple modality optical microscopy. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/57293

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/57293