不同功能性膝支架之生物力學分析

Biomechanical analysis of the different functional knee braces

檔案

日期

2014

類型

語言

中文

摘要

功能性膝支架常見於前十字韌帶損傷或是前十字韌帶重建的患者身上,其功能是改善膝關節穩定度。然而,市面上相同功能之膝支架產品多樣化且支架能提供的保護程度無從得知。本研究目的是調查不同的膝支架對於膝關節帶來的生物力學效應。研究進行人體動作與肌電圖訊號分析實驗,以常見活動作為主要測試動作,包含走路和上下樓作為測試之動作,分別探討無穿戴支架與Xeleton和Armor支架之間膝關節生物力學之差異,包含站立早期之最大垂直地面反作用力、最大膝彎曲角度、最大膝彎曲力矩、肌肉活性以及共同收縮比值。實驗結果顯示,有無穿戴支架於不同測試活動下,兩組支架皆不會明顯影響地面反作用力、膝彎曲角度、肌肉活性和共同收縮比值。然而,在力矩上,上樓時穿戴Xeleton和Armor支架,皆顯著增加未穿戴支架時之膝關節彎曲力矩高峰值的52%和26%。於走路和下樓,僅Xeleton支架分別顯著增加未穿戴時之彎曲力矩高峰值41%和119%。支架間比較,於上樓時之力矩值,Xeleton增加的力矩量為Armor支架的一倍,且達顯著差異。而本研究結論,有無穿戴支架比較下,穿戴Xeleton和Armor支架皆顯著增加上樓時之膝彎曲力矩值。於走路和下樓活動,只有Xeleton支架顯著增加力矩值。支架間比較,於上樓時之力矩,Xeleton增加的力矩量為Armor支架的一倍。
Functional knee braces (FKBs) have become a popular adjunct to manage anterior cruciate ligament (ACL) injury or ACL reconstruction. They are selectively used during the rehabilitation process to improve the knee stability. However, the knee brace in market is variety and few study is focused on effect of protection of knee joint. To investigate the biomechanical effect between the different knee joint braces. This study underwent human motion analysis and electromyography(EMG) measurement. Subjects are asked to perform three daily activities including walking, stair ascent, and stair descent. The biomechanical alterations are investigated under three conditions consisted of no brace, Xeleton and Armor brace. During early stance phase, each subject’s peak vertical ground reaction (vGRF), peak knee flexion angle, peak knee flexion moment, muscle activity and co-contraction ratio (CCR) were measured. Experimental results indicated no significant difference in peak vGRF and vertical knee flexion angle, muscle activity and CCR between wearing and un-wearing the braces under different movement. However, during stair ascent, both braces had increased the flexion moment in the 52% and 26%, respectively. Compared to un-wearing, only Xeleton brace had significance in the 41% and 191% increased for walking and stair descending, respectively. There is significant difference in flexion moment between Xeleton and Armor braces, and Xeleton was one time as much as Armor brace during stair ascent. The conclusions is both braces had increased the flexion moment during stair ascent between wearing and un-wearing the braces. Between two braces, Xeleton brace increased the flexion moment was one time as much as Armor brace during stair ascent.
顯示完整詮釋資料 統計資料

引用此條目

黃景珊 (2014). 不同功能性膝支架之生物力學分析. https://thesis.lib.nycu.edu.tw/handle/20.500.14371/57729

BibTeX RIS

引用文字依 APA 第 7 版格式自動產生,使用前請再核對。

分享

永久網址:https://thesis.lib.nycu.edu.tw/handle/20.500.14371/57729