鈮鎂酸鉛高頻超音波探針阻抗匹配與應用

The Lead Magnesium Niobate-Lead Titanate (PMN-PT) High Frequency Ultrasound Needle Transducer Impedance Matching and Application

檔案

日期

2014

類型

語言

中文

摘要

摘要
硬脊膜外腔麻醉術為目前臨床上廣泛應用於術前麻醉以及術後止痛的區域性的麻醉手術。手術實施過程以醫師的手感將麻醉硬膜外針刺入至黃韌帶與硬脊膜間的硬脊膜外腔,注入麻醉劑以達到麻醉的效果,然而其手術的失敗率約2至20%。目前已有多種輔助定位方法與技術來避免穿刺失敗,在我們先前的研究中,已開發30 MHz之高頻超音波來協助偵測黃韌帶與硬脊膜兩層訊號,作為硬膜外針的針尖定位以達到提前警示之效果。
由於高頻訊號在軟組織中會有強訊號衰減,因此我們分別開發30 MHz以及20 MHz較低頻的超音波探針以及使用阻抗匹配的方式來加強反射訊號以及穿透深度。其流程為透過壓電晶體等效電路以及變壓器來計算合適的電容與電感值,並將阻值調至50Ω以達到傳輸線阻抗匹配。根據實驗結果顯示,使用阻抗匹配方式可有效分別增加20以及30 MHz探針訊號效能27.3%以及72.9%。
在本研究中成功地透過使用阻抗匹配的方式有效將20MHz以及30MHz探針訊號強度提升,此在探針訊號的頻寬以及解析度上也有明顯的改善。因此探針經阻抗匹配後可有更佳的訊雜比以期望增加辨識黃韌帶與硬脊膜兩層訊號的成功率,進而達到降低硬脊膜穿刺失敗的風險。

關鍵字:硬脊膜外腔麻醉術、高頻超音波探針、阻抗匹配
Abstract
In clinical, the Epidural anesthesia is a well-established technique in obstetric anesthesia. To identification the epidural space is the most fundamental and difficult step, and studies show that the failure rate has ranged from 2% to 20%. To facilitate identify the epidural space, a variety of methods and equipment have been proposed. In our previous studied, we have developed the 30 MHz high-frequency ultrasound needle to position the tip of needle by detecting the two significant peaks of the ligamentum flavum and dura mater.
We had developed lower frequency ultrasound needle (20 MHz), and matched the impedance to enhance the amplitude and intensity to overcome the short penetrated length problem. The procedure is used the equivalent circuit and RF Transformer to calculate the proper inductance value to eliminate the capacity and adjustment the resistance to 50Ω to match the transmission line impedance. The results show that it is valid to improve the efficiency up to the 27.3% and 72.9% by using the impedance matching in 30 MHz and 20 MHz ultrasound frequency needle respectively.
In this study, both of ultrasound needles of the 30 MHz and 20 MHz had increased the signal amplitude and also improved the bandwidth and resolution. Thus, we are anticipating that the needle with the impedance matching circuit can have a better SNR to detect Epidural space, which will decrease the rate of epidural failure.

Key word: Epidural anesthesia, High-frequency ultrasound needle, Impedance matching