探討空氣負離子控制測試艙內單粒徑及多粒徑分布次微米微粒之去除效能
Removal Efficiency of Monodisperse and Polydisperse Submicron Particles in a Test Chamber by using a Negative Air Ionizer
摘要
暴露於空氣中的懸浮微粒(如細微粒及超細微粒)與人們不良健康反應如心肺、呼吸系統及過敏性疾病有相關性。現今人們在室內活動的時間長,因此室內懸浮微粒之暴露與其健康息息相關。一般室內微粒為多粒徑分布。而單粒徑分布微粒行為較單純,易於以理論模式作驗證。過去研究鮮少以空氣負離子(Negative Air ion, NAI)針對單粒徑分布次微米微粒(Monodisperse Submicron Particles, MSPs)之沉降去除作深入探討,釐清NaCl MSP與多粒徑分布次微米微粒(Polydisperse Submicron Particles, PSPs)兩者沉降去除現象之差異有助於將理論模式運用在實際面上。
研究於濕度50%之不銹鋼測試艙(0.216 m3)內進行實驗。探討兩種影響微粒沉降的因素,其一為微粒粒徑分布(MSPs及PSPs);其二為自由流速度0.56、1.20、2.0 m/s (以低、中及高風速表示)的影響。研究採用粒徑範圍30-300 nm之氯化鈉及油酸氣膠微粒作測試。PSPs由霧化器產生,PSPs通過電移動度篩分器篩出五種粒徑之MSPs (30、50、100、170、300 nm)。掃描式微粒粒徑分析儀監測微粒的濃度與粒徑分布,由此計算微粒數目濃度變化分率、衰減係數、去除效率之增強因子及效力。
研究結果顯示,空氣負離子對氯化鈉微粒的沉降效率較油酸高,且於低風速的條件下最佳。於測試的粒徑範圍內,粒徑越大則微粒數目濃度衰減係數(k)越小,而PSPs數量濃度衰減速率高於MSPs是因為PSPs膠結係數大於MSPs。空氣負離子增進微粒去除效率之增進因子(EF)隨著粒徑的增加而上升。次微米NaCl微粒的EF值在單粒徑分布大於多粒徑分布,而油酸則相反(次微米油酸微粒的EF在多粒徑分布>單粒徑分布)。在NAI作用下,可增進微粒沉降速率最高可達80倍。實驗系統中在低風速條件對於單粒徑分布之NaCl去除效力(H)最佳的為92.9~95.8 %;去除效力最差(79.2 %)的是多粒徑分布之次微米油酸微粒及高風速條件中的30 nm微粒。
空氣負離子可以有效地增進次微米微粒的沉降去除。測試艙內之微粒與負離子作用的實際情形複雜,涉及多種機制(如擴散、電場帶電及膠結作用)交互作用,然而,MSPs及PSPs的衰減係數曲線結果與理論模式在整體趨勢方面是具有良好的一致性。
研究於濕度50%之不銹鋼測試艙(0.216 m3)內進行實驗。探討兩種影響微粒沉降的因素,其一為微粒粒徑分布(MSPs及PSPs);其二為自由流速度0.56、1.20、2.0 m/s (以低、中及高風速表示)的影響。研究採用粒徑範圍30-300 nm之氯化鈉及油酸氣膠微粒作測試。PSPs由霧化器產生,PSPs通過電移動度篩分器篩出五種粒徑之MSPs (30、50、100、170、300 nm)。掃描式微粒粒徑分析儀監測微粒的濃度與粒徑分布,由此計算微粒數目濃度變化分率、衰減係數、去除效率之增強因子及效力。
研究結果顯示,空氣負離子對氯化鈉微粒的沉降效率較油酸高,且於低風速的條件下最佳。於測試的粒徑範圍內,粒徑越大則微粒數目濃度衰減係數(k)越小,而PSPs數量濃度衰減速率高於MSPs是因為PSPs膠結係數大於MSPs。空氣負離子增進微粒去除效率之增進因子(EF)隨著粒徑的增加而上升。次微米NaCl微粒的EF值在單粒徑分布大於多粒徑分布,而油酸則相反(次微米油酸微粒的EF在多粒徑分布>單粒徑分布)。在NAI作用下,可增進微粒沉降速率最高可達80倍。實驗系統中在低風速條件對於單粒徑分布之NaCl去除效力(H)最佳的為92.9~95.8 %;去除效力最差(79.2 %)的是多粒徑分布之次微米油酸微粒及高風速條件中的30 nm微粒。
空氣負離子可以有效地增進次微米微粒的沉降去除。測試艙內之微粒與負離子作用的實際情形複雜,涉及多種機制(如擴散、電場帶電及膠結作用)交互作用,然而,MSPs及PSPs的衰減係數曲線結果與理論模式在整體趨勢方面是具有良好的一致性。
Exposure to particulate matters (e.g., fine and ultrafine particles) is associated with a variety of adverse health effects, including cardiopulmonary, respiratory and allergy diseases. Because people nowadays spend most of their time in indoor environments, their health is closely related to the exposure to indoor aerosol particles. In general, indoor aerosol particles are polydispersely distributed. However, the behaviour of monodisperse particle is simpler and more easily proven by theoretical model. There were rare researches focusing on the deposition removal of monodisperse submicron particles (MSPs) enhanced by negative air ions (NAIs). Understanding the difference between the deposition removal of NaCl MSPs and polydisperse submicron particles (PSPs) enhanced by NAI has become an urgent work and is benificial to apply the theoretical model in real situation.
The particle-removal experiments were conducted in a stainless steel test chamber (0.216 m3) under 50% relative humidity (RH). The factors affect the deposition removal of particles was evaluated in this study. These factors included the particle size distribution (MSPs and PSPs) and the freestream air velocity (FAV) which was set at 0.56, 1.20 and 2.0 m/s,corresponding to low, medium and high wind speed, repectively. Sodium chloride (NaCl) and oleic acid aerosols with sizes range from 30 to 300 nm were tested. PSPs were generated from an atomizer and the MSPs (30, 50, 100, 170, 300 nm) were generated by passing the PSPs through a differential mobility analyzer. The number concentration and size distribution of the submicron particles in the chamber were monitored in real time with the Scanning Mobility Particle Sizer (SMPS®). The data from SMPS was used to calculate the decay constant (k), enhancement factor of removal rate (EF) and removal effectiveness (H) of aerosol particles.
The deposition removal efficiency of NaCl paritcles enhanced by NAI was higher than that oleic acid and is better under low wind speed. Because the coagulation coefficient of PSP was larger than MSP, the decay constant of PSP was higher than that of MSP. In the tested size region, decay constant decreased with the increase of particle size. In contrast, the EF increased with the particle size. The EF of NaCl MSPs was higher than NaCl PSPs, but in the cases of oleic acid particle, the EF of PSPs was higher. By operating NAI, the deposition rate of particles could be enhanced to as high as 80 times compared to that without NAI operating. The removal effectiveness (H) of NaCl MSP ranged from 92.5 to 95.8 % under the low wind speed. The removal effectiveness of 30 nm oleic acid particle (PSPs) was lowest (79.2 %) under high wind speed.
Conclusively, NAI is effective in enhancing the deposition removal of submicron particles. Although, the interaction between particles and negative air ions in the chamber is complicated and is involved with diffusion, field charging and coagulation, the trend of decay constant measured in MSP and PSP experiment is corresponding to that predicted by theoretical model.
The particle-removal experiments were conducted in a stainless steel test chamber (0.216 m3) under 50% relative humidity (RH). The factors affect the deposition removal of particles was evaluated in this study. These factors included the particle size distribution (MSPs and PSPs) and the freestream air velocity (FAV) which was set at 0.56, 1.20 and 2.0 m/s,corresponding to low, medium and high wind speed, repectively. Sodium chloride (NaCl) and oleic acid aerosols with sizes range from 30 to 300 nm were tested. PSPs were generated from an atomizer and the MSPs (30, 50, 100, 170, 300 nm) were generated by passing the PSPs through a differential mobility analyzer. The number concentration and size distribution of the submicron particles in the chamber were monitored in real time with the Scanning Mobility Particle Sizer (SMPS®). The data from SMPS was used to calculate the decay constant (k), enhancement factor of removal rate (EF) and removal effectiveness (H) of aerosol particles.
The deposition removal efficiency of NaCl paritcles enhanced by NAI was higher than that oleic acid and is better under low wind speed. Because the coagulation coefficient of PSP was larger than MSP, the decay constant of PSP was higher than that of MSP. In the tested size region, decay constant decreased with the increase of particle size. In contrast, the EF increased with the particle size. The EF of NaCl MSPs was higher than NaCl PSPs, but in the cases of oleic acid particle, the EF of PSPs was higher. By operating NAI, the deposition rate of particles could be enhanced to as high as 80 times compared to that without NAI operating. The removal effectiveness (H) of NaCl MSP ranged from 92.5 to 95.8 % under the low wind speed. The removal effectiveness of 30 nm oleic acid particle (PSPs) was lowest (79.2 %) under high wind speed.
Conclusively, NAI is effective in enhancing the deposition removal of submicron particles. Although, the interaction between particles and negative air ions in the chamber is complicated and is involved with diffusion, field charging and coagulation, the trend of decay constant measured in MSP and PSP experiment is corresponding to that predicted by theoretical model.