提高實驗溫度以縮短可靠度驗證時間之可行性分析
Feasibility Analysis of Raising the Experimental Temperature to Shorten the Validation Duration in Reliability Testing.
摘要
個案公司為台灣某第三方認證實驗室,主要服務的內容為提供半導體產品所有的驗證分析服務。一般電子產品在上市之前,為保證產品品質之穩定性,依照產品需求進行可靠度測試。近期因客戶提出可靠度測試實驗中的高溫工作壽命測試 (High Temperature Operating Life, HTOL)驗證的時間過長,影響產品上市時間。因此,個案公司根據Arrhenius Model所計算出來的結果,提升驗證溫度可以達成縮短驗證時間之目的,但須考量提升驗證溫度對產品特性的影響,因此本研究將利用變異數分析(Analysis of Variance,ANOVA)分析使用原始溫度與提升溫度下電流的特性是否有顯著差異。本研究結果顯示,電流特性在溫度125°C及140°C之間沒有顯著差異,產品也通過電性測試。因此HTOL驗證溫度可由140℃取代125℃,驗證時間將減少52.3%。
The case company, a third-party certification lab in Taiwan, primarily offers verification and analysis services for semiconductor products. Before electronic products are launched, reliability testing is conducted to ensure stable product quality based on product requirements. Recently, customers have pointed out that the High Temperature Operating Life (HTOL) verification takes too much time and impacted product launch schedules. Thus, the case company considered increasing the verification temperature based on the Arrhenius Model to reduce verification time. However, the effect of higher temperatures on product characteristics must be considered. Therefore, this study employed Analysis of Variance (ANOVA) to analyze if there's a significant difference in current characteristics between original and elevated temperatures. Results show no significant difference in current characteristics between 125°C and 140°C, and the products passed electrical performance tests. Therefore, the HTOL verification temperature can be replaced from 140℃ to 125℃, and the verification time will be reduced by 52.3%.