外加電場對生物晶片上蛋白質排列方向性之影響
Effects of eletric field on the bio-chip and protein orientation
摘要
本研究探討一新式製程,將能增加生物晶片之生產及量測效率與敏銳度。本研究嘗試於生物晶片製造時,固定生物分子的過程中外加一800,000(V/m)之電場,藉以控制生物分子之方向性,並以改變的電場方向達成改變生物分子固定於基材時的角度,增加生物分子之活性區暴露於晶片表層的機率,進而提高生物晶片效率,從而發展一套有更高效能之生物晶片。
研究中利用原子力顯微鏡(AFM)測量蛋白質抗原與抗體間結合力。此方法以Protein A固定於原子力顯微鏡之探針,Protein A-Anti抗體固定於矽基材,並以兩者間結合力大小差異判斷裸露在晶片表層之活性區比例多寡。
測量方式包括使用一可調式電場,再測量蛋白質抗原與抗體間平均結合力大小與晶片上蛋白質抗體之方向。使用無外加電場所固定之Protein A探針測量固定Protein A-Anti免疫球蛋白之晶片時以45度電場所製作之試片有最高結合力6424.192pN。在使用無外加電場所固定蛋白質CB1a探針測量固定CB1a-Anti免疫球蛋白之晶片時,在22.5度電場時所製作之試片亦有最高結合力729.09pN。因而推測這兩組製程條件所製作之晶片,其上方的免疫球蛋白的活性區有較多比例裸露於表層,因蛋白質結構上的不同故兩種蛋白質的最佳鍵結角度並不同,且呈現各自正確的結合角度,故有較大的結合力量,此方法可提升藥物篩選晶片之敏銳度,使其應用更廣泛。利用原子力顯微鏡可以準確測量兩者間之結合力大小,有效定量晶片效率,是一有利之技術,未來期望可持續發展微陣列技術與AFM統計數據庫,以作為生物感測器製造之參考。
研究中利用原子力顯微鏡(AFM)測量蛋白質抗原與抗體間結合力。此方法以Protein A固定於原子力顯微鏡之探針,Protein A-Anti抗體固定於矽基材,並以兩者間結合力大小差異判斷裸露在晶片表層之活性區比例多寡。
測量方式包括使用一可調式電場,再測量蛋白質抗原與抗體間平均結合力大小與晶片上蛋白質抗體之方向。使用無外加電場所固定之Protein A探針測量固定Protein A-Anti免疫球蛋白之晶片時以45度電場所製作之試片有最高結合力6424.192pN。在使用無外加電場所固定蛋白質CB1a探針測量固定CB1a-Anti免疫球蛋白之晶片時,在22.5度電場時所製作之試片亦有最高結合力729.09pN。因而推測這兩組製程條件所製作之晶片,其上方的免疫球蛋白的活性區有較多比例裸露於表層,因蛋白質結構上的不同故兩種蛋白質的最佳鍵結角度並不同,且呈現各自正確的結合角度,故有較大的結合力量,此方法可提升藥物篩選晶片之敏銳度,使其應用更廣泛。利用原子力顯微鏡可以準確測量兩者間之結合力大小,有效定量晶片效率,是一有利之技術,未來期望可持續發展微陣列技術與AFM統計數據庫,以作為生物感測器製造之參考。
Proteins immobilized on chip (protein bio-chip) have been considered as one of main biotechnologies popularly applied in medical diagnosis and life science. Optimization of the chip efficiency is an expectation. The optimum protein orientation to the best position for undergoing protein-protein interaction may be pursued. In this research, immobilization of protein on chip under the influence of external electric field (EEF) was introduced. A device for producing EEF with adjustable angle from 0o to 360o was built. By using atomic force microscopy (AFM) providing the binding force measurement, this EEF device was applied to measure the efficiency of protein-protein interaction.
Protein A immobilized on AFM tip (afm-Protein A) with its antibody antiProtein A immobilized on chip (chip-antiProtein A) was used as an example for their binding tests under EEF. Results showed that the unbinding forces between afm-Protein A and chip-antiProtein A were in average of 1070.03 pN (without EEF) and 6424.192 pN (with EEF at the best angle 45o). Consequently, the effectiveness of protein-protein interaction was increased to over 600% under EEF as compared with the conventional one (without EEF adjustment).
A custom peptide CB1a is also increased to over 200% under EEF (729.09 pN at the best angle 22.5o) as compared with the conventional one (337.35pN without EEF adjustment).
The best angle pursued by using adjustable EEF for improving the efficiency of protein bio-chip was therefore proposed and could be applied to protein industry and related fields in the future.
Protein A immobilized on AFM tip (afm-Protein A) with its antibody antiProtein A immobilized on chip (chip-antiProtein A) was used as an example for their binding tests under EEF. Results showed that the unbinding forces between afm-Protein A and chip-antiProtein A were in average of 1070.03 pN (without EEF) and 6424.192 pN (with EEF at the best angle 45o). Consequently, the effectiveness of protein-protein interaction was increased to over 600% under EEF as compared with the conventional one (without EEF adjustment).
A custom peptide CB1a is also increased to over 200% under EEF (729.09 pN at the best angle 22.5o) as compared with the conventional one (337.35pN without EEF adjustment).
The best angle pursued by using adjustable EEF for improving the efficiency of protein bio-chip was therefore proposed and could be applied to protein industry and related fields in the future.