摘要
本論文提出單股絕緣線與雙股電源線電流量測用封閉式線圈與平面線圈之設計。所設計之單股絕緣線電流量測模組,其能量採集電路可在無外部電源或電池情況下提供長時間之電流量測,而附加的ZigBee通訊模組則提供了自動讀表的功能。針對雙股之電源線電流量測模組,在家用設備電流量測中我們展示了其非侵入式量測的能力,且實際應用上感測元件基本所需的線性度特性與校正方法,在本論文也都有驗證與設計;此外電極片組被設計來量測雙股電源線上之電壓,並用來計算感測器安裝的位置。為了解決不同量測距離其量測係數並不相同的問題,本論文使用了疊代方法,並搭配事先建立好的量測係數與安裝距離關係表來解決該問題,跟固定單一電壓校正係數相比,誤差可以從-37百分比降到±5個百分比,在本論文中我們成功克服了水平方向0.5毫米與垂直方向±1.0毫米感測器安裝偏移的影響。
In this study, an enclosed coil and a planar coil are designed to measure the current in a 1C insulated wire and a 2C power cord, respectively. The proposed module for the 1C insulated wire includes an energy harvesting circuit that provides long-term measurement without additional power supply or battery. The use of a ZigBee module supports automatic meter reading. The proposed module for the 2C power cord is demonstrated to have capability for noninvasive current measurement of household appliances. The basic requirements and the linearity and calibration methods have been verified and prepared for practical applications. A set of electrodes is also used to measure the voltage on the 2C power cord and assists in calculating the installed position of sensors. The problem related to the measurement factors of different measuring positions is addressed by using an iterative method and installing a table of measurement factors built in relation to the various installed positions. The displacements, which measure 0.5 and ±1.0 mm in the horizontal and vertical directions, are overcome. Unlike the results obtained with a fixed voltage-calibrating factor, the errors can drop from -37 % down to ±5 %.